{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,8,30]],"date-time":"2024-08-30T17:19:48Z","timestamp":1725038388916},"reference-count":18,"publisher":"Wiley","issue":"8","license":[{"start":{"date-parts":[[2012,2,14]],"date-time":"2012-02-14T00:00:00Z","timestamp":1329177600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clinical Anatomy"],"published-print":{"date-parts":[[2012,11]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The structures of superior mediastinum and their spatial relationships are complex and difficult to master. This study aimed to compare visualization of the superior mediastinum based on computed tomography (CT) images and on the thin sections of the Chinese visible human (CVH) data set to provide a sectional anatomical basis for diagnostic imaging of superior mediastinal pathology. CVH sections of the mediastinum of a 35\u2010year old male were compared with plain and enhanced CT images of a 45\u2010year old male without apparent abnormalities in the upper chest. In addition, a three\u2010dimensional model based on the CVH sections was compared with a model based on CT images. Although CT imaging is noninvasive and can be carried out in many individuals, its weakness is clearly the visualization of small soft tissue structures. In this respect, the sectional anatomical approach of the CVH images is complementary, as it visualizes these small soft tissue structures due to the higher resolution in the plain of sectioning and the color of the different structures in the section. Three\u2010dimensional surface and volume rendering of reconstructions of the CVH data set can help medical students and less experienced thoracic surgeons to familiarize themselves with the topographic anatomy of the superior mediastinal structures and their spatial relationships, and thus with interpreting CT images of patients. Clin. Anat. 25:1051\u20131061, 2012. \u00a9 2012 Wiley Periodicals, Inc.<\/jats:p>","DOI":"10.1002\/ca.22048","type":"journal-article","created":{"date-parts":[[2012,2,14]],"date-time":"2012-02-14T16:12:55Z","timestamp":1329235975000},"page":"1051-1061","source":"Crossref","is-referenced-by-count":4,"title":["Comparative study of thin sectional anatomical images from Chinese Visible Human data set and computed tomography images of superior mediastinum"],"prefix":"10.1002","volume":"25","author":[{"given":"Yi","family":"Wu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Na","family":"Luo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Li\u2010Wen","family":"Tan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bing\u2010Ji","family":"Fang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ying","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bing","family":"Xie","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hao\u2010Tong","family":"Xu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nan","family":"Hu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei\u2010Ping","family":"Yang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Wu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wouter H.","family":"Lamers","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shao\u2010Xiang","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2012,2,14]]},"reference":[{"key":"e_1_2_6_2_1","first-page":"377","article-title":"Tridimensional ultrasound of the prostate","volume":"59","author":"Bermudez Villaverde R","year":"2006","journal-title":"Arch Esp Urol"},{"key":"e_1_2_6_3_1","first-page":"351","article-title":"Surgical anatomy of the anterior mediastinum","volume":"78","author":"Biondi A","year":"2007","journal-title":"Ann Ital Chir"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00276-008-0417-3"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00276-004-0282-7"},{"key":"e_1_2_6_6_1","first-page":"194","article-title":"Virtual acupuncture human based on Chinese visible human dataset","volume":"119","author":"Heng PA","year":"2006","journal-title":"Stud Health Technol Inform"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00276-010-0627-3"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0090-4295(99)00606-8"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1464-410X.2006.06536.x"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ics.2005.03.245"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11547-006-0031-6"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00276-003-0188-9"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-0185(199804)253:2<49::AID-AR8>3.0.CO;2-9"},{"key":"e_1_2_6_14_1","first-page":"172","article-title":"Mechanical virtual human of China","volume":"21","author":"Wang CT","year":"2006","journal-title":"J Med Biomech"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00276-010-0625-5"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.2005.862744"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1002\/ar.b.10035"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.0021-8782.2004.00274.x"},{"key":"e_1_2_6_19_1","doi-asserted-by":"publisher","DOI":"10.1002\/ca.20273"}],"container-title":["Clinical Anatomy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fca.22048","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ca.22048","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,21]],"date-time":"2023-11-21T06:58:18Z","timestamp":1700549898000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ca.22048"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,2,14]]},"references-count":18,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2012,11]]}},"alternative-id":["10.1002\/ca.22048"],"URL":"https:\/\/doi.org\/10.1002\/ca.22048","archive":["Portico"],"relation":{},"ISSN":["0897-3806","1098-2353"],"issn-type":[{"value":"0897-3806","type":"print"},{"value":"1098-2353","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,2,14]]}}}