{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,10,7]],"date-time":"2023-10-07T07:12:27Z","timestamp":1696662747728},"reference-count":16,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2014,11,25]],"date-time":"2014-11-25T00:00:00Z","timestamp":1416873600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"name":"Department of Veterans Affairs, BLSR&D, and the PNC Foundation (UD)"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clinical Anatomy"],"published-print":{"date-parts":[[2015,5]]},"abstract":"<jats:p>The objective of this study is to establish normative waveform data for the external branch of the superior laryngeal nerve (SLN) utilizing laryngeal surface electrodes and intraoperative neurophysiological monitoring (IONM) in conjunction with a clinical neurophysiologist. A retrospective chart review of 91 consecutive at\u2010risk SLN were identified in 51 patients in whom IONM using laryngeal surface electrodes was performed by a clinical neurophysiologist using Dragonfly (Neurovision Medical Products, Ventura, CA) recording electrodes and a Protektor (Natus Medical Inc., San Carlos, CA)16 channel\u2010 intraoperative nerve monitoring system. Inclusion criteria were met for 30 SLN. Data collected included preoperative diagnosis, surgical procedure, rates of nerve identification and stimulation, and waveform characteristics. Waveform analysis for 30 SLN yielded a peak latency of 4.0\u2009\u00b1\u20090.2 ms, onset latency 2.3\u2009\u00b1\u20090.1 ms, peak\u2010to\u2010peak amplitude of 220.4\u2009\u00b1\u200931.1 \u00b5V, onset\u2010to\u2010peak amplitude of 186.0\u2009\u00b1\u200925.0 \u00b5V, and stimulation current threshold of 0.55\u2009\u00b1\u20090.03 mA (data\u2009=\u2009mean\u2009\u00b1\u2009SEM). Two patients had abnormal SLN function documented clinically on postoperative laryngoscopic examination. Laryngeal surface electrodes were successfully utilized to identify and monitor SLN function intraoperatively. IONM using laryngeal surface electrodes enables analysis of waveform morphology and latency in addition to threshold and amplitude data obtained with the traditional NIM system, potentially improving the performance of nerve monitoring during thyroid surgery. Clin. Anat. 28:460\u2013466, 2015. \u00a9 2014 Wiley Periodicals, Inc.<\/jats:p>","DOI":"10.1002\/ca.22487","type":"journal-article","created":{"date-parts":[[2014,11,25]],"date-time":"2014-11-25T14:45:36Z","timestamp":1416926736000},"page":"460-466","source":"Crossref","is-referenced-by-count":6,"title":["Superior laryngeal nerve monitoring using laryngeal surface electrodes and intraoperative neurophysiological monitoring during thyroidectomy"],"prefix":"10.1002","volume":"28","author":[{"given":"Benjamin L.","family":"Hodnett","sequence":"first","affiliation":[{"name":"Department of Otolaryngology University of Pittsburgh Medical Center, Eye and Ear Institute Pittsburgh Pennsylvania"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nicole C.","family":"Schmitt","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology University of Pittsburgh Medical Center, Eye and Ear Institute Pittsburgh Pennsylvania"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniel R.","family":"Clayburgh","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology\u2010Head and Neck Surgery Oregon Health and Science University Portland Oregon"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alex","family":"Burkowsky","sequence":"additional","affiliation":[{"name":"Clinical Neurophysiology Tech, Procirca\u2014Center for Clinical Neurophysiology (CCN), UPMC Presbyterian Hospital Pittsburgh Pennsylvania"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jeffrey","family":"Balzer","sequence":"additional","affiliation":[{"name":"Neuroscience &amp; Acute and Tertiary Care Nursing, Center for Clinical Neurophysiology (CCN), UPMC Presbyterian Hospital Pittsburgh Pennsylvania"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Parthasarathy D.","family":"Thirumala","sequence":"additional","affiliation":[{"name":"Center for Clinical Neurophysiology (CCN), UPMC Presbyterian Hospital Suite B\u2010400 Pittsburgh Pennsylvania"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Umamaheswar","family":"Duvvuri","sequence":"additional","affiliation":[{"name":"University of Pittsburgh Medical Center, VA Pittsburgh Health System, Eye and Ear Institute Pittsburgh Pennsylvania"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2014,11,25]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00268-012-1547-7"},{"key":"e_1_2_8_3_1","first-page":"S1","article-title":"External branch of the superior laryngeal nerve monitoring during thyroid and parathyroid surgery: International Neural Monitoring Study Group standards guideline statement","volume":"4","author":"Barczy\u0144ski M","year":"2013","journal-title":"Laryngoscope 123 Suppl"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1017\/S0022215100108412"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9610(05)80723-8"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1002\/lary.24446"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00464-008-0098-3"},{"key":"e_1_2_8_8_1","volume-title":"Physical Medicine and Rehabilitation Board Review","author":"Freeman TL","year":"2004"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00415-012-6497-3"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1001\/archotol.124.3.301"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.5435\/00124635-200407000-00008"},{"key":"e_1_2_8_12_1","first-page":"999","article-title":"The superior laryngeal nerve in thyroid surgery","volume":"102","author":"Lennquist S","year":"1987","journal-title":"Surgery"},{"key":"e_1_2_8_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.surg.2009.09.023"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00268-013-2148-9"},{"key":"e_1_2_8_15_1","first-page":"S1","article-title":"Electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery: International standards guideline statement","volume":"1","author":"Randolph GW","year":"2011","journal-title":"Laryngoscope 121 Suppl"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.1097\/SLA.0b013e3181b17342"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0030-6665(03)00175-0"}],"container-title":["Clinical Anatomy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fca.22487","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fca.22487","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ca.22487","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,6]],"date-time":"2023-10-06T15:05:24Z","timestamp":1696604724000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ca.22487"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,11,25]]},"references-count":16,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2015,5]]}},"alternative-id":["10.1002\/ca.22487"],"URL":"https:\/\/doi.org\/10.1002\/ca.22487","archive":["Portico"],"relation":{},"ISSN":["0897-3806","1098-2353"],"issn-type":[{"value":"0897-3806","type":"print"},{"value":"1098-2353","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,11,25]]}}}