{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,28]],"date-time":"2026-01-28T07:49:31Z","timestamp":1769586571950,"version":"3.49.0"},"reference-count":23,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2002,7,12]],"date-time":"2002-07-12T00:00:00Z","timestamp":1026432000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Cathet Cardio Intervent"],"published-print":{"date-parts":[[2002,8]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Transcatheter closure of a patent foramen ovale (PFO) offers a valuable alternative to surgery in selected patients with presumed paradoxical embolism. Like for all other devices, several complications have been described. Although the majority of these complications are caused by technical problems of the device itself, thrombosis is a relatively infrequent but feared finding, as it may result in recurrent embolic events and persistent neurological deficits. The majority of the complications after implantation are dealt with by surgical removal of the device and subsequent surgical closure of the PFO. The present case report describes biatrial thrombosis of a PFO device that was successfully treated with thrombolytics and GP IIb\/IIIa receptor blockers. In stable patients, this pharmaco\u2010therapeutic approach should be attempted to save the thrombosed PFO device and could therefore offer a valuable alternative to surgical removal of the device. Cathet Cardiovasc Intervent 2002;56:522\u2013526. \u00a9 2002 Wiley\u2010Liss, Inc.<\/jats:p>","DOI":"10.1002\/ccd.10253","type":"journal-article","created":{"date-parts":[[2002,10,6]],"date-time":"2002-10-06T11:46:55Z","timestamp":1033904815000},"page":"522-526","source":"Crossref","is-referenced-by-count":17,"title":["Thrombosis of a patent foramen ovale closure device: Thrombolytic management"],"prefix":"10.1002","volume":"56","author":[{"given":"Marc","family":"Vanderheyden","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Willem","family":"Willaert","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philip","family":"Claessens","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Inge","family":"Branders","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paul","family":"Ex","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paul","family":"Vermeersch","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2002,7,12]]},"reference":[{"key":"e_1_2_4_2_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.101.8.893"},{"key":"e_1_2_4_3_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.103.10.e56"},{"key":"e_1_2_4_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(94)90750-1"},{"key":"e_1_2_4_5_2","doi-asserted-by":"publisher","DOI":"10.1161\/str.14.5.829b"},{"key":"e_1_2_4_6_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.25.4.782"},{"key":"e_1_2_4_7_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM198805053181802"},{"key":"e_1_2_4_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(88)92944-3"},{"key":"e_1_2_4_9_2","doi-asserted-by":"publisher","DOI":"10.1159\/000117442"},{"key":"e_1_2_4_10_2","first-page":"57","article-title":"Prevention of recurrent cerebral ischemic events in patients with patent foramen ovale and cryptogenic strokes or transient ischemic attacks","volume":"15","author":"Cujec B","year":"1999","journal-title":"Can J Cardiol"},{"key":"e_1_2_4_11_2","first-page":"II171","article-title":"Surgical patent foramen ovale closure for prevention of paradoxical embolism\u2010related cerebrovascular ischemic events","volume":"100","author":"Dearani JA","year":"1999","journal-title":"Circulation"},{"key":"e_1_2_4_12_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.28.12.2376"},{"key":"e_1_2_4_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(00)00514-3"},{"key":"e_1_2_4_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1010-7940(97)00270-4"},{"key":"e_1_2_4_15_2","doi-asserted-by":"publisher","DOI":"10.1067\/mje.2001.108539"},{"key":"e_1_2_4_16_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.86.6.1902"},{"key":"e_1_2_4_17_2","doi-asserted-by":"publisher","DOI":"10.4065\/76.10.1057"},{"key":"e_1_2_4_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(99)00296-9"},{"key":"e_1_2_4_19_2","first-page":"25","article-title":"Frequency of occluder\u2010related atrial thrombi despite different prophylactic therapy after transcatheter closure of a patent foramen ovale","volume":"21","author":"Franke HPK","year":"2000","journal-title":"Eur Heart J"},{"key":"e_1_2_4_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-510X(98)00243-3"},{"key":"e_1_2_4_21_2","doi-asserted-by":"publisher","DOI":"10.3109\/14017439209099047"},{"key":"e_1_2_4_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(92)90437-Z"},{"key":"e_1_2_4_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(97)00345-8"},{"key":"e_1_2_4_24_2","doi-asserted-by":"publisher","DOI":"10.1212\/WNL.57.11.2122"}],"container-title":["Catheterization and Cardiovascular Interventions"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fccd.10253","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ccd.10253","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,19]],"date-time":"2023-11-19T10:58:55Z","timestamp":1700391535000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ccd.10253"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2002,7,12]]},"references-count":23,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2002,8]]}},"alternative-id":["10.1002\/ccd.10253"],"URL":"https:\/\/doi.org\/10.1002\/ccd.10253","archive":["Portico"],"relation":{},"ISSN":["1522-1946","1522-726X"],"issn-type":[{"value":"1522-1946","type":"print"},{"value":"1522-726X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2002,7,12]]}}}