{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,11,12]],"date-time":"2023-11-12T14:54:00Z","timestamp":1699800840974},"reference-count":23,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2005,10,24]],"date-time":"2005-10-24T00:00:00Z","timestamp":1130112000000},"content-version":"vor","delay-in-days":11254,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Cathet. Cardiovasc. Diagn."],"published-print":{"date-parts":[[1975,1]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Routine use of the hydrogen platinum electrode system (HPES) in 1,375 consecutive cardiac catheterizations facilitated shunt detection in 171 patients, led to the diagnosis of unsuspected shunts in 18 patients, and was of particular value in accurately localizing unusual left\u2010to\u2010right shunts.<\/jats:p><jats:p>Left\u2010to\u2010right shunts were detected in 171 patients (12% of the total catheterizations). Eighteen unsuspected shunts (10% of the total shunts, or 1% of the total catheterizations) were found. Atrial septal defect (ASD), partial anomalous pulmonary drainage (PAPVD), ventricular septal defect (VSD), and ruptured Valsalva aneurysm were demonstrated, usually associated with other congenital or acquired lesions.<\/jats:p><jats:p>HPES was of particular value in accurately localizing the venous drainage of 38 unusual or complex lesions with left\u2010to\u2010right shunting.<\/jats:p><jats:p>Five patients with rheumatic mitral valve disease had PAPVD, a higher incidence (1.2% of rheumatic mitral valve disease) than had previously been reported.<\/jats:p><jats:p>The rationale for use of a sensitive shunt detection method as a routine part of the catheterization procedure is discussed.<\/jats:p>","DOI":"10.1002\/ccd.1810010212","type":"journal-article","created":{"date-parts":[[2007,2,28]],"date-time":"2007-02-28T23:22:10Z","timestamp":1172704930000},"page":"207-221","source":"Crossref","is-referenced-by-count":3,"title":["Routine use of the Hydrogen Platinum Electrode System in Shunt Detection"],"prefix":"10.1002","volume":"1","author":[{"given":"Michael R.","family":"Wilson","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mary E.","family":"Fontana","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Charles F.","family":"Wooley","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2005,10,24]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1126\/science.130.3377.709"},{"key":"e_1_2_1_3_2","first-page":"797","article-title":"Detection and direct recording of left\u2010to\u2010right shunts with the hydrogen electrode catheter","volume":"46","author":"Clark LC","year":"1959","journal-title":"Surgery"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(64)90331-X"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.31.5.705"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.RES.11.6.1004"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(64)90039-6"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.19.6.898"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.14.5.826"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(69)90476-1"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(71)90374-2"},{"key":"e_1_2_1_12_2","first-page":"235","article-title":"The science of cardiac catheterization in the diagnosis of congenital heart disease","volume":"4","author":"Levin AR","year":"1972","journal-title":"Cardiovasc Clin"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(71)90089-0"},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.49.3.512"},{"key":"e_1_2_1_15_2","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.36.5.428"},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.48.6.1215"},{"key":"e_1_2_1_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(61)90516-6"},{"key":"e_1_2_1_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(62)90085-6"},{"key":"e_1_2_1_19_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.28.4.542"},{"key":"e_1_2_1_20_2","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.30.2.168"},{"key":"e_1_2_1_21_2","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.31.6.766"},{"key":"e_1_2_1_22_2","first-page":"731","article-title":"False\u2010positive tests with hydrogen\u2010platinum electrode technique for left\u2010to\u2010right shunts with electrode in the pulmonary artery wedge","volume":"26","author":"Hirose T","year":"1962","journal-title":"Circulation"},{"key":"e_1_2_1_23_2","first-page":"952","article-title":"The use of hydrogen inhalation in detection of intracardiac shunts","volume":"39","author":"Heimann KW","year":"1965","journal-title":"S Afr Med J"},{"key":"e_1_2_1_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9343(71)90200-2"}],"container-title":["Catheterization and Cardiovascular Diagnosis"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fccd.1810010212","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ccd.1810010212","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,19]],"date-time":"2023-10-19T01:34:03Z","timestamp":1697679243000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ccd.1810010212"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1975,1]]},"references-count":23,"journal-issue":{"issue":"2","published-print":{"date-parts":[[1975,1]]}},"alternative-id":["10.1002\/ccd.1810010212"],"URL":"https:\/\/doi.org\/10.1002\/ccd.1810010212","archive":["Portico"],"relation":{},"ISSN":["0098-6569","1097-0304"],"issn-type":[{"value":"0098-6569","type":"print"},{"value":"1097-0304","type":"electronic"}],"subject":[],"published":{"date-parts":[[1975,1]]}}}