{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,31]],"date-time":"2025-10-31T21:49:53Z","timestamp":1761947393406},"reference-count":10,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2005,10,25]],"date-time":"2005-10-25T00:00:00Z","timestamp":1130198400000},"content-version":"vor","delay-in-days":7237,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Cathet. Cardiovasc. Diagn."],"published-print":{"date-parts":[[1986,1]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Percutaneous transluminal balloon pulmonary valvuloplasty has been performed since 1982. In publications, the most critical problems mentioned are severe systemic hypotension and bradycardia due to stasis of blood flow.<\/jats:p><jats:p>A triple\u2010lumen balloon was developed to allow more rapid inflation and deflation and to preserve the preexistent forward blood flow during maximal inflation. Only a slight systemic hypotension and no bradycardia were seen in the first two patients with pulmonary valve stenosis treated with this type of balloon. Thus, the maximal inflation time is not a critical parameter, whereas with the former types of balloon, maximal inflation times were critical, and, if longer than 5 to 10 sec, severe systemic hypotension was registered.<\/jats:p><jats:p>We conclude that the triple\u2010lumen pulmonary valve\u2010dilatation balloon catheter is superior to the single\u2010lumen balloon catheter used up to now.<\/jats:p>","DOI":"10.1002\/ccd.1810120516","type":"journal-article","created":{"date-parts":[[2007,3,1]],"date-time":"2007-03-01T04:37:19Z","timestamp":1172723839000},"page":"352-356","source":"Crossref","is-referenced-by-count":11,"title":["New triple\u2010lumen balloon catheter for percutaneous (pulmonary) valvuloplasty"],"prefix":"10.1002","volume":"12","author":[{"given":"Eduard J. M.","family":"van den Berg","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Menco G.","family":"Niemeyer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thijs W. M.","family":"Plokker","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sjef M. P. G.","family":"Ernst","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jos","family":"de Korte","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2005,10,25]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.30.5.654"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1055\/s-0028-1108161"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(82)90047-9"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM198208263070907"},{"key":"e_1_2_1_6_2","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1161\/01.CIR.69.3.554","article-title":"Percutaneous transluminal balloon valvuloplasty for pulmonary valve stenosis","volume":"69","author":"Kan JS","journal-title":"Circulation"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(82)90491-X"},{"key":"e_1_2_1_8_2","first-page":"403","article-title":"Percutane Transluminale Ballonvalvuloplastiek als nieuwe Behandelingsmethode voor Pulmonalisklepstenose","volume":"129","author":"Hess J","year":"1985","journal-title":"Ned Tijdsch v Geneesk"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(85)90283-8"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.142.3.571"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.141.2.6457318"}],"container-title":["Catheterization and Cardiovascular Diagnosis"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fccd.1810120516","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ccd.1810120516","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,20]],"date-time":"2023-10-20T14:10:55Z","timestamp":1697811055000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ccd.1810120516"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1986,1]]},"references-count":10,"journal-issue":{"issue":"5","published-print":{"date-parts":[[1986,1]]}},"alternative-id":["10.1002\/ccd.1810120516"],"URL":"https:\/\/doi.org\/10.1002\/ccd.1810120516","archive":["Portico"],"relation":{},"ISSN":["0098-6569","1097-0304"],"issn-type":[{"value":"0098-6569","type":"print"},{"value":"1097-0304","type":"electronic"}],"subject":[],"published":{"date-parts":[[1986,1]]}}}