{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,5,12]],"date-time":"2024-05-12T17:02:31Z","timestamp":1715533351128},"reference-count":10,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2005,12,11]],"date-time":"2005-12-11T00:00:00Z","timestamp":1134259200000},"content-version":"vor","delay-in-days":5338,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Cathet. Cardiovasc. Diagn."],"published-print":{"date-parts":[[1991,5]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>To determine adequate and effective balloon diameters of the Inoue balloon catheter, we reviewed clinical results and characteristics of the Inoue balloon catheter, especially the relationship between the intra\u2010balloon pressure and the balloon diameter, experimentally and clinically, in 46 patients with mitral stenosis undergoing percutaneous transvenous mitral commissurotomy (PTMC). Mitral valve area increased from 1.1 \u00b1 0.3 to 2.1 \u00b1 0.3 cm<jats:sup>2<\/jats:sup> in all patients after PTMC. Based on balloon diameter settings, mitral valve area increased from 1.3\u00b10.4 to 2.3\u00b10.5 cm<jats:sup>2<\/jats:sup> in patients treated with a balloon setting greater than 26 mm in diameter, from 1.1 \u00b10.3 to 2.0\u00b10.5 cm<jats:sup>2<\/jats:sup> in patients with a balloon setting at 26 mm in diameter, and from 1.1\u00b10.4 to 1.7\u00b10.4 cm<jats:sup>2<\/jats:sup> in those treated with a balloon setting less than 26 mm in diameter, with an increase in mitral valve area of 1.0\u00b10.6, 0.9\u00b10.4, and 0.7\u00b10.2 cm<jats:sup>2<\/jats:sup>, respectively. There was a significant difference between the increase in mitral valve area at a setting of 26 mm in diameter and that observed at a setting less than 26 mm in diameter. We next investigated differences between balloon diameter settings and actual balloon diameters measured from cineangiograms at maximum balloon inflation. The ratio of actual balloon diameter to a setting diameter of less than 26 mm was smaller than that of 26 mm. To evaluate the reason for the difference, we investigated the relationship between intra\u2010balloon pressure and balloon diameter. In the prototype Inoue balloon catheter, intra\u2010balloon pressure increases from 1.0 kg\/cm<jats:sup>2<\/jats:sup> at 20 mm in diameter to 2.2 kg\/cm<jats:sup>2<\/jats:sup> at 30 mm in diameter at atmospheric pressure. In conclusion, the increase in mitral valve area was inadequate when the balloon was less than 26 mm in diameter because of inadequate intra\u2010balloon pressure. We, therefore, recommend a balloon size set above 26 mm to obtain adequate intra\u2010balloon pressure when using the Inoue balloon catheter.<\/jats:p>","DOI":"10.1002\/ccd.1810230105","type":"journal-article","created":{"date-parts":[[2007,3,1]],"date-time":"2007-03-01T20:52:35Z","timestamp":1172782355000},"page":"14-19","source":"Crossref","is-referenced-by-count":7,"title":["Balloon diameter of the inoue balloon catheter during percutaneous transvenous mitral commissurotomy: Clinical and experimental study"],"prefix":"10.1002","volume":"23","author":[{"given":"Seiki","family":"Nagata","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fuminobu","family":"Ishikura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takashi","family":"Yamabe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masashi","family":"Akaike","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kohji","family":"Kimura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kunio","family":"Miyatake","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2005,12,11]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"crossref","first-page":"384","DOI":"10.1016\/S0022-5223(19)37390-8","article-title":"Clinical application of transvenous mitral commissurotomy by a new balloon catheter","volume":"87","author":"Inoue K","year":"1984","journal-title":"J Thorac Cardiovasc Surg"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(88)90061-0"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.79.1.47"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.81.1.46"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(90)90203-A"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.75.4.778"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.76.3.628"},{"key":"e_1_2_1_9_2","first-page":"II","article-title":"Assessment of the mechanism of balloon valvuloplasty from pressure\u2010volume curves during balloon inflation","volume":"78","author":"Grossman W","year":"1988","journal-title":"Circulation [Suppl]"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.60.4.299"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(88)90089-7"}],"container-title":["Catheterization and Cardiovascular Diagnosis"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fccd.1810230105","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ccd.1810230105","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,23]],"date-time":"2023-10-23T03:09:18Z","timestamp":1698030558000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ccd.1810230105"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1991,5]]},"references-count":10,"journal-issue":{"issue":"1","published-print":{"date-parts":[[1991,5]]}},"alternative-id":["10.1002\/ccd.1810230105"],"URL":"https:\/\/doi.org\/10.1002\/ccd.1810230105","archive":["Portico"],"relation":{},"ISSN":["0098-6569","1097-0304"],"issn-type":[{"value":"0098-6569","type":"print"},{"value":"1097-0304","type":"electronic"}],"subject":[],"published":{"date-parts":[[1991,5]]}}}