{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,10,28]],"date-time":"2023-10-28T05:40:04Z","timestamp":1698471604987},"reference-count":32,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2005,12,8]],"date-time":"2005-12-08T00:00:00Z","timestamp":1134000000000},"content-version":"vor","delay-in-days":3935,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Cathet. Cardiovasc. Diagn."],"published-print":{"date-parts":[[1995,3]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>To determine if slow inflation or slow deflation (compared to standard rapid inflation\/ deflation) would minimize coronary arterial dissection, we randomized 162 lesions from 136 patients undergoing coronary angioplasty with polyolefin copolymer balloons to slow oscillating (1 atmosphere\/20 sec) vs. rapid (over 30 sec) inflation and slow (over 15 sec) vs. rapid deflation. The incidence of any dissection was nearly identical in the four inflation\/deflation groups. The incidence of severe dissection, however, was significantly higher for the slow inflation\/slow deflation group compared to the other three groups (38% vs. 15%, <jats:italic>P<\/jats:italic> = .024). For angioplasty performed with polyolefin copolymer balloons, slow deflation combined with slow oscillating inflation is associated with more frequent severe dissections.<\/jats:p>","DOI":"10.1002\/ccd.1810340105","type":"journal-article","created":{"date-parts":[[2007,3,2]],"date-time":"2007-03-02T06:38:04Z","timestamp":1172817484000},"page":"202-209","source":"Crossref","is-referenced-by-count":6,"title":["Coronary dissection resulting from angioplasty with slow oscillating vs. rapid inflation and slow vs. rapid deflation"],"prefix":"10.1002","volume":"34","author":[{"given":"James C.","family":"Blankenship","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alan C.","family":"Ford","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sheldon D.","family":"Henry","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carolin M.","family":"Frey","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2005,12,8]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(90)90386-4"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1002\/clc.4960111204"},{"key":"e_1_2_1_4_2","first-page":"1211","article-title":"An analysis of outcome following PTCA: An autopsy series","volume":"114","author":"Prayson RA","year":"1990","journal-title":"Arch Pathol Lab Med"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(93)90714-C"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.85.3.1012"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.82.3.739"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.72.5.1044"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.79.5.1035"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(91)90780-O"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.66.1.3"},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(92)91303-L"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.1810230203"},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(93)90539-O"},{"key":"e_1_2_1_15_2","first-page":"34","article-title":"Angioplasty outcome using long balloons in high\u2010risk lesions","volume":"19","author":"Savas V","year":"1992","journal-title":"J Am Coll Cardiol"},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(89)90267-2"},{"key":"e_1_2_1_17_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.78.3.557"},{"key":"e_1_2_1_18_2","first-page":"II","article-title":"Balloon material as a risk factor for coronary angioplasty procedural complications","volume":"84","author":"Berry KJ","year":"1991","journal-title":"Circulation"},{"key":"e_1_2_1_19_2","first-page":"291A","article-title":"Effects of angioplasty balloon material and lesion characteristics on the incidence of coronary dissection in 2150 dilated lesions","volume":"21","author":"Raymenants E","year":"1993","journal-title":"J Am Coll Cardiol"},{"key":"e_1_2_1_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(92)90905-E"},{"key":"e_1_2_1_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(92)90171-I"},{"key":"e_1_2_1_22_2","first-page":"263","article-title":"Gradual, low\u2010pressure and prolonged (10 minutes) protected inflations decrease complications and improve results of proximal LAD angioplasty","volume":"12","author":"Farcot JC","year":"1991","journal-title":"Eur Heart J"},{"key":"e_1_2_1_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(90)90005-I"},{"key":"e_1_2_1_24_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.1810290305"},{"key":"e_1_2_1_25_2","first-page":"122","article-title":"Minimally invasive angioplasty:Acute and long term results with low pressure dilatation with a non\u2010compliant balloon during percutaneous transluminal coronary angioplasty","volume":"5","author":"Shawl FA","year":"1993","journal-title":"J Inv Cardiol"},{"key":"e_1_2_1_26_2","first-page":"119","article-title":"Minimally invasive angioplasty:An editorial","volume":"5","author":"Shawl FA","year":"1993","journal-title":"J Inv Cardiol"},{"key":"e_1_2_1_27_2","first-page":"82","article-title":"Minimally invasive angioplasty:A technique that minimizes arterial trauma and thus reduces complications","volume":"2778","author":"Shawl FA","year":"1993","journal-title":"Cathet Cardiovasc Diagn"},{"key":"e_1_2_1_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(94)90224-0"},{"key":"e_1_2_1_29_2","first-page":"9","article-title":"Coronary artery changes after PTCA","volume":"6","year":"1985","journal-title":"Manual of operations NHLBI PTCA Registry"},{"key":"e_1_2_1_30_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.82.4.1193"},{"key":"e_1_2_1_31_2","first-page":"10","article-title":"The workhorse balloon, Part 1:Inflation technique","volume":"4","author":"Blankenship JC","year":"1994","journal-title":"Cardio Interv"},{"key":"e_1_2_1_32_2","first-page":"I","article-title":"Angioplasty balloon materials are a determinant of the dilating force generated at the site of severe stenosis","volume":"86","author":"Gray WA","year":"1992","journal-title":"Circulation"},{"key":"e_1_2_1_33_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(93)90600-H"}],"container-title":["Catheterization and Cardiovascular Diagnosis"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fccd.1810340105","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ccd.1810340105","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,27]],"date-time":"2023-10-27T03:41:54Z","timestamp":1698378114000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ccd.1810340105"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1995,3]]},"references-count":32,"journal-issue":{"issue":"3","published-print":{"date-parts":[[1995,3]]}},"alternative-id":["10.1002\/ccd.1810340105"],"URL":"https:\/\/doi.org\/10.1002\/ccd.1810340105","archive":["Portico"],"relation":{},"ISSN":["0098-6569","1097-0304"],"issn-type":[{"value":"0098-6569","type":"print"},{"value":"1097-0304","type":"electronic"}],"subject":[],"published":{"date-parts":[[1995,3]]}}}