{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T19:38:52Z","timestamp":1787168332771,"version":"build-2736575974"},"reference-count":28,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2009,11,10]],"date-time":"2009-11-10T00:00:00Z","timestamp":1257811200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Cathet Cardio Intervent"],"published-print":{"date-parts":[[2010,9]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:styled-content>Objective:<\/jats:styled-content>\n                    To describe the use of the amplatzer vascular plug (plug 1) and amplatzer vascular plug II (plug 2) in patients with congenital cardiovascular disease (CCVD).\n                    <jats:styled-content>Background:<\/jats:styled-content>\n                    Plugs 1 and 2 have recently been made available. We report our experience describing plugs 1 and 2 in patients with CCVD highlighting the versatility of these devices.\n                    <jats:styled-content>Methods:<\/jats:styled-content>\n                    All patients with CCVD who underwent a vascular occlusion procedure at the Children's Hospital of Philadelphia between August 1, 2004 and July 30, 2009 with plug 1 or 2 were included. A retrospective review was performed.\n                    <jats:styled-content>Results:<\/jats:styled-content>\n                    Fifty patients underwent vascular occlusion procedure with plug 1 or 2 at a median age of 2.0 years (range 1 day to 47 years) and median weight of 12.3 kg (range 3.1\u201398 kg). Fifty\u2010eight plugs (43% plug 1, 57% plug 2) were placed in 52 vessels. Of these vessels, 20 (38%) were patent ductus arteriosus (PDA), 14 (27%) venous collaterals, 5 (10%) aorto\u2010pulmonary collaterals, 4 (8%) modified Blalock Taussig shunts, 3 (5%) porto\u2010systemic connections, and 6 (12%) miscellaneous structures. Excluding a patient who was lost to follow\u2010up, complete occlusion was observed in 100% of vessels either at the time of the catheterization or at follow\u2010up. There were two complications (3.8%).\n                    <jats:styled-content>Conclusions:<\/jats:styled-content>\n                    Plugs 1 and 2 are safe and effective devices that can be used in a variety of blood vessels in patients with CCVD. Plug 2 is particularly useful in closure of high\u2010flow, tubular structures, especially type C PDA's. \u00a9 2009 Wiley\u2010Liss, Inc.\n                  <\/jats:p>","DOI":"10.1002\/ccd.22370","type":"journal-article","created":{"date-parts":[[2009,11,10]],"date-time":"2009-11-10T12:27:27Z","timestamp":1257856047000},"page":"411-417","source":"Crossref","is-referenced-by-count":39,"title":["The amplatzer vascular plug and amplatzer vascular plug II for vascular occlusion procedures in 50 patients with congenital cardiovascular disease"],"prefix":"10.1002","volume":"76","author":[{"given":"Matthew","family":"Schwartz","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew C.","family":"Glatz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan J.","family":"Rome","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew J.","family":"Gillespie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2010,8,24]]},"reference":[{"key":"e_1_2_7_2_2","first-page":"259","article-title":"Closure of persistent ductus arteriosus without thoracotomy","volume":"12","author":"Portsmann W","year":"1967","journal-title":"Ger Med Monthly"},{"key":"e_1_2_7_3_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.20555"},{"key":"e_1_2_7_4_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00270-007-9044-3"},{"key":"e_1_2_7_5_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.21474"},{"key":"e_1_2_7_6_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00246-009-9397-2"},{"key":"e_1_2_7_7_2","first-page":"E151","article-title":"Rapid transcatheter occlusion of a coronary cameral fistula using a three\u2010lobed vascular occlusion plug","volume":"21","author":"Meerkin D","year":"2009","journal-title":"J Invasive Cardiol"},{"key":"e_1_2_7_8_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.21546"},{"key":"e_1_2_7_9_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.21264"},{"key":"e_1_2_7_10_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00246-005-1081-6"},{"key":"e_1_2_7_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(89)90064-7"},{"key":"e_1_2_7_12_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00246-004-0857-4"},{"key":"e_1_2_7_13_2","first-page":"E121","article-title":"Successful occlusion of multiple pulmonary arteriovenous fistulas using amplatzer vascular plugs","volume":"18","author":"Peirone AR","year":"2006","journal-title":"J Invasive Cardiol"},{"key":"e_1_2_7_14_2","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1016\/S0873-2159(15)30137-9","article-title":"Hereditary hemorrhagic telangiectasia and pulmonary arteriovenous malformations\u2014Embolization with Amplatzer vascular plug","volume":"15","author":"Santos CS","year":"2009","journal-title":"Rev Port Pneumol"},{"key":"e_1_2_7_15_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.20921"},{"key":"e_1_2_7_16_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.20228"},{"key":"e_1_2_7_17_2","doi-asserted-by":"publisher","DOI":"10.1017\/S1047951107000510"},{"key":"e_1_2_7_18_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.21860"},{"key":"e_1_2_7_19_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00246-008-9266-4"},{"key":"e_1_2_7_20_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.20347"},{"key":"e_1_2_7_21_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00246-007-9031-0"},{"key":"e_1_2_7_22_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00246-008-9268-2"},{"key":"e_1_2_7_23_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.21831"},{"key":"e_1_2_7_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvir.2008.07.012"},{"key":"e_1_2_7_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2008.03.001"},{"key":"e_1_2_7_26_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00246-009-9501-7"},{"key":"e_1_2_7_27_2","first-page":"263","article-title":"Transcatheter closure of patent ductus arteriosus using the amplatzer duct occluder","volume":"3","author":"Waight DJ","year":"2001","journal-title":"Curr Interv Cardiol Rep"},{"key":"e_1_2_7_28_2","doi-asserted-by":"publisher","DOI":"10.1002\/1522-726X(200009)51:1<50::AID-CCD11>3.0.CO;2-6"},{"key":"e_1_2_7_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2004.03.074"}],"container-title":["Catheterization and Cardiovascular Interventions"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fccd.22370","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ccd.22370","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,10]],"date-time":"2023-10-10T15:59:08Z","timestamp":1696953548000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ccd.22370"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,8,24]]},"references-count":28,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2010,9]]}},"alternative-id":["10.1002\/ccd.22370"],"URL":"https:\/\/doi.org\/10.1002\/ccd.22370","archive":["Portico"],"relation":{},"ISSN":["1522-1946","1522-726X"],"issn-type":[{"value":"1522-1946","type":"print"},{"value":"1522-726X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,8,24]]}}}