{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,29]],"date-time":"2025-10-29T19:15:36Z","timestamp":1761765336858},"reference-count":5,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2011,2,2]],"date-time":"2011-02-02T00:00:00Z","timestamp":1296604800000},"content-version":"vor","delay-in-days":1,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Cathet Cardio Intervent"],"published-print":{"date-parts":[[2011,2]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p><jats:styled-content>Objectives<\/jats:styled-content>: We have developed a method using transthoracic echocardiography in establishing optimal visualization of the aortic root, to reduce the amount of contrast medium used in each patient. <jats:styled-content>Background<\/jats:styled-content>: During transcatheter aortic valve implantation, it is necessary to obtain an optimal fluoroscopic projection for deployment of the valve showing the aortic ostium with the three cusps aligned in the beam direction. This may require repeat aortic root angiograms at this stage of the procedure with a high amount of contrast medium with a risk of detrimental influence on renal function. <jats:styled-content>Methods<\/jats:styled-content>: We studied the conventional way and an echo guided way to optimize visualisation of the aortic root. Echocardiography was used initially allowing easier alignment of the image intensifier with the transducer's direction. <jats:styled-content>Results<\/jats:styled-content>: Contrast volumes, radiation\/fluoroscopy exposure times, and postoperative creatinine levels were significantly less in patients having the echo\u2010guided orientation of the optimal fluoroscopic angles compared with patients treated with the conventional approach. <jats:styled-content>Conclusion<\/jats:styled-content>: We present a user\u2010friendly echo\u2010guided method to facilitate fluoroscopy adjustment during transcatheter aortic valve implantation. In our series, the amounts of contrast medium and radiation have been significantly reduced, with a concomitant reduction in detrimental effects on renal function in the early postoperative phase. \u00a9 2011 Wiley\u2010Liss, Inc.<\/jats:p>","DOI":"10.1002\/ccd.22747","type":"journal-article","created":{"date-parts":[[2010,9,8]],"date-time":"2010-09-08T05:42:08Z","timestamp":1283924528000},"page":"272-275","source":"Crossref","is-referenced-by-count":6,"title":["Echo\u2010guided presentation of the aortic valve minimises contrast exposure in transcatheter valve recipients"],"prefix":"10.1002","volume":"77","author":[{"given":"Jacek","family":"Baranowski","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Henrik","family":"Ahn","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wolfgang","family":"Freter","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Niels\u2010Erik","family":"Nielsen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eva","family":"Nylander","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Birgitta","family":"Janerot\u2010Sjoberg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Sandborg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lars","family":"Wallby","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2011,2,2]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.0000047200.36165.B8"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2008.06.028"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejcts.2006.10.034"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1875-2136(08)70270-5"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1093\/ejechocard\/jen245"}],"container-title":["Catheterization and Cardiovascular Interventions"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fccd.22747","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ccd.22747","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,10]],"date-time":"2023-10-10T17:35:49Z","timestamp":1696959349000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ccd.22747"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,2]]},"references-count":5,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2011,2]]}},"alternative-id":["10.1002\/ccd.22747"],"URL":"https:\/\/doi.org\/10.1002\/ccd.22747","archive":["Portico"],"relation":{},"ISSN":["1522-1946","1522-726X"],"issn-type":[{"value":"1522-1946","type":"print"},{"value":"1522-726X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,2]]}}}