{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,31]],"date-time":"2025-10-31T21:54:26Z","timestamp":1761947666825},"reference-count":20,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2011,6,16]],"date-time":"2011-06-16T00:00:00Z","timestamp":1308182400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Cathet Cardio Intervent"],"published-print":{"date-parts":[[2011,7]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p><jats:styled-content>Objectives<\/jats:styled-content>: To compare complication rates of a collagen\u2010mediated closure device, suture\u2010mediated closure technique and manual compression for access site management following balloon aortic valvuloplasty (BAV). <jats:styled-content>Background<\/jats:styled-content>: Vascular complications, including perforation, limb ischemia, ateriovenous fistulas, and pseudoaneurysm, are a common source of morbidity in patients undergoing BAV with large bore femoral artery access. The available options for closure of the access site include manual compression, suture\u2010mediated closure devices, and recently reported collagen\u2010based closure devices. <jats:styled-content>Methods<\/jats:styled-content>: The study cohort consisted of 333 patients with severe aortic stenosis undergoing BAV. Patients were divided into four groups according to access closure method: (1) Manual compression in 64 (19.2%); (2) Proglide 6 Fr in 162 (48.6%); (3) Angio\u2010Seal 8 Fr in 89 (26.75%); and (4) Prostar 10 Fr in18 (5.4%). <jats:styled-content>Results<\/jats:styled-content>: There were no significant differences in baseline characteristics among the groups; although the Prostar group was had more males and the Angio\u2010Seal group reported a lower incidence of renal failure and peripheral vascular disease. The Angio\u2010Seal group had shorter procedural duration times compared with the other groups. In the Angio\u2010Seal group (<jats:italic>n<\/jats:italic> = 47, 52.8%), a 10 Fr sheath size was primarily used to access the femoral artery, as compared with the manual compression and Proglide groups, which used a 12 Fr sheath in 29 (45.3%) and 66 patients (40.7%), respectively. A 13 Fr sheath was used in the Prostar group (<jats:italic>n<\/jats:italic> = 11, 61.1%), <jats:italic>P<\/jats:italic> &lt; 0.001. The device failure rate was significantly higher in the Proglide group (<jats:italic>n<\/jats:italic> = 20, 12.3%) as compared with Angio\u2010Seal (<jats:italic>n<\/jats:italic> = 3, 3.3%) and Prostar groups (<jats:italic>n<\/jats:italic> = 1, 5.5%), <jats:italic>P<\/jats:italic> = 0.03. Serious vascular complications requiring intervention were significantly higher in the manual compression group (<jats:italic>n<\/jats:italic> = 11, 17.1%) compared with the Proglide (<jats:italic>n<\/jats:italic> = 11, 6.7%), Angio\u2010Seal (<jats:italic>n<\/jats:italic> = 5, 5.6%), and Prostar groups (<jats:italic>n<\/jats:italic> = 5, 1%), <jats:italic>P<\/jats:italic> &lt; 0.001. The requirement for blood transfusion in the Angio\u2010Seal group was significantly lower (<jats:italic>n<\/jats:italic> = 7, 7.8%) as compared with the manual compression (<jats:italic>n<\/jats:italic> = 20, 31.2%), Proglide (<jats:italic>n<\/jats:italic> = 35, 21.6%), and Prostar groups (<jats:italic>n<\/jats:italic> = 5, 27.7%), <jats:italic>P<\/jats:italic> &lt; 0.001. <jats:styled-content>Conclusion<\/jats:styled-content>: In our case series, collagen\u2010based closure devices and suture\u2010mediated closure devices had fewer vascular complications than manual compression for hemostasis following BAV. Patient selection for collagen\u2010based versus suture\u2010mediated closure requires further study. \u00a9 2011 Wiley\u2010Liss, Inc.<\/jats:p>","DOI":"10.1002\/ccd.22940","type":"journal-article","created":{"date-parts":[[2011,1,13]],"date-time":"2011-01-13T18:44:07Z","timestamp":1294944247000},"page":"119-124","source":"Crossref","is-referenced-by-count":16,"title":["Comparison of closure strategies after balloon aortic valvuloplasty: Suture mediated versus collagen based versus manual"],"prefix":"10.1002","volume":"78","author":[{"given":"Itsik","family":"Ben\u2010dor","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Patrick","family":"Looser","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nelson","family":"Bernardo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gabriel","family":"Maluenda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rebecca","family":"Torguson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhenyi","family":"Xue","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joseph","family":"Lindsay","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Augusto D.","family":"Pichard","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lowell F.","family":"Satler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ron","family":"Waksman,","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2011,6,16]]},"reference":[{"key":"e_1_2_6_2_2","article-title":"Percutaneous femoral artery access with Prostar device for innovative mitral and aortic interventions","author":"Vergnat M","journal-title":"Eur J Cardiothorac Surg in press"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.22295"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00059-009-3252-3"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(10)80120-2"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.84.6.2383"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM199107043250104"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.1810250103"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2004.08.061"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.22085"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.22289"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8183.2006.00142.x"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.21333"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1001\/jama.291.3.350"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.22238"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1583\/08-2622.1"},{"key":"e_1_2_6_17_2","first-page":"592","article-title":"Percutaneous suture closure for management of large French size arterial puncture in aortic valvuloplasty","volume":"13","author":"Solomon LW","year":"2001","journal-title":"J Invasive Cardiol"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2007.12.029"},{"key":"e_1_2_6_19_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.21711"},{"key":"e_1_2_6_20_2","first-page":"130","article-title":"Initial experience of removal of 10\u2010French sheaths using the 8\u2010French Angio\u2010Seal vascular closure device","volume":"22","author":"Fallahi A","year":"2010","journal-title":"J Invasive Cardiol"},{"key":"e_1_2_6_21_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.20646"}],"container-title":["Catheterization and Cardiovascular Interventions"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fccd.22940","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ccd.22940","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,10]],"date-time":"2023-10-10T13:17:34Z","timestamp":1696943854000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ccd.22940"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,6,16]]},"references-count":20,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2011,7]]}},"alternative-id":["10.1002\/ccd.22940"],"URL":"https:\/\/doi.org\/10.1002\/ccd.22940","archive":["Portico"],"relation":{},"ISSN":["1522-1946","1522-726X"],"issn-type":[{"value":"1522-1946","type":"print"},{"value":"1522-726X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,6,16]]}}}