{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,3]],"date-time":"2026-10-03T15:42:25Z","timestamp":1791042145294,"version":"4.1.0"},"reference-count":19,"publisher":"Wiley","issue":"7","license":[{"start":{"date-parts":[[2011,11,21]],"date-time":"2011-11-21T00:00:00Z","timestamp":1321833600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Cathet Cardio Intervent"],"published-print":{"date-parts":[[2011,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p><jats:styled-content>Objective:<\/jats:styled-content> We report our experience with the transapical transcatheter \u201cValve in valve\u201d implantation (T\u2010VIV) in patients with a failed mitral or tricuspid bioprosthesis; we briefly review the pertinent literature, and discuss some technical aspects of this procedure. <jats:styled-content>Background:<\/jats:styled-content> Redo valve surgery for failure of a mitral or tricuspid bioprosthesis might become extremely challenging, both because of the patients' condition, which is frequently poor, and for the technical aspects of the operation itself, that can be very demanding. T\u2010VIV has been widely employed with good results for the treatment of aortic bioprosthesis failure, and could represent an attractive option in this setting. <jats:styled-content>Methods:<\/jats:styled-content> Four patients with multiple comorbidities (age: 63\u201083 years; logistic Euroscore: 37.2\u201081.5) underwent T\u2010VIV at our institution for failure of a mitral [<jats:ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"#bib3\">3<\/jats:ext-link>] or tricuspid [<jats:ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"#bib1\">1<\/jats:ext-link>] bioprosthesis. A 26mm Sapien valve was used in all cases. All the mitral procedures were performed via a transapical approach. The tricuspid procedure was performed via a transjugular approach. <jats:styled-content>Results:<\/jats:styled-content> The first mitral procedure was complicated by the splaying of the xenograft stents and embolization of the valve. The procedure was converted to conventional surgery, and the patient died on postoperative day 1. In the subsequent procedures, the valve was positioned more atrially, and was fixed to the malfunctioning xenograft sewing ring. All subsequent procedures were successful, all patients were discharged home and were alive and well at follow\u2010up. <jats:styled-content>Conclusions:<\/jats:styled-content> The results of T\u2010VIV procedure in the mitral position have been suboptimal, and four of the sixteen patients reported to date died. However, all patients were extremely diseased, and some of the reported failures were related to amendable technical factors relative to the surgical access or to the valve deployment technique. With increasing experience, this procedure might become indicated as an alternative to conventional surgery in selected patients, encouraging increased use of bioprosthesis, and marking a pivotal change in the management of valvular disease. \u00a9 2011 Wiley Periodicals, Inc.<\/jats:p>","DOI":"10.1002\/ccd.23112","type":"journal-article","created":{"date-parts":[[2011,4,28]],"date-time":"2011-04-28T15:39:56Z","timestamp":1304005196000},"page":"987-995","source":"Crossref","is-referenced-by-count":44,"title":["Transcatheter valve in valve implantation for failed mitral and tricuspid bioprosthesis"],"prefix":"10.1002","volume":"78","author":[{"given":"Alfredo Giuseppe","family":"Cerillo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesca","family":"Chiaramonti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michele","family":"Murzi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefano","family":"Bevilacqua","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elisa","family":"Cerone","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cataldo","family":"Palmieri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paolo","family":"Del Sarto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Massimiliano","family":"Mariani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sergio","family":"Berti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mattia","family":"Glauber","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2011,11,21]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2008.08.015"},{"key":"e_1_2_6_3_2","unstructured":"BridgewaterB GummertJ WaltonPKH KinsmanR. Fourth EACTS adult cardiac surgical database report. Dendrite's Specialist Clinical Database Reports 2010."},{"issue":"1","key":"e_1_2_6_4_2","first-page":"II98","article-title":"Reoperation for bioprosthetic mitral structural failure: Risk assessment","volume":"108","author":"Jamieson WR","year":"2003","journal-title":"Circulation"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejcts.2008.05.006"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/1010-7940(93)90046-E"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1055\/s-0029-1246705"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2007.03.030"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehn285"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2008.10.016"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.22618"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.109.924613"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2010.04.101"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCINTERVENTIONS.110.957555"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2010.11.026"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.22324"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2010.02.061"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejcts.2009.12.048"},{"key":"e_1_2_6_19_2","article-title":"Trans\u2010jugular tricuspid valve\u2010in\u2010valve implantation: A safe and effective approach","author":"Cerillo AG","journal-title":"Ann Thorac Surg"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejcts.2008.04.039"}],"container-title":["Catheterization and Cardiovascular Interventions"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fccd.23112","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ccd.23112","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,20]],"date-time":"2023-11-20T10:43:35Z","timestamp":1700477015000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ccd.23112"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,11,21]]},"references-count":19,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2011,12]]}},"alternative-id":["10.1002\/ccd.23112"],"URL":"https:\/\/doi.org\/10.1002\/ccd.23112","archive":["Portico"],"relation":{},"ISSN":["1522-1946","1522-726X"],"issn-type":[{"value":"1522-1946","type":"print"},{"value":"1522-726X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,11,21]]}}}