{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,8,30]],"date-time":"2023-08-30T05:12:06Z","timestamp":1693372326420},"reference-count":19,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2013,12,24]],"date-time":"2013-12-24T00:00:00Z","timestamp":1387843200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Cathet Cardio Intervent"],"published-print":{"date-parts":[[2014,7]]},"abstract":"<jats:p>Significant aortic regurgitation after TAVI results in lack of symptomatic and prognostic benefit from the procedure and generally requires intervention. While most of the regurgitations can be successfully targeted with standard techniques, occasional patients have restrictive calcification resistant to post\u2010dilatation and significant regurgitation persists. We present a case of refractory aortic regurgitation successfully treated with percutaneous paravalvular leak closure. An 81\u2010year\u2010old man with symptomatic severe aortic stenosis underwent a transfemoral CoreValve TAVI in December 2009. He had significant aortic regurgitation refractory to medical and interventional therapy including balloon post\u2010dilatation, valve repositioning and valve\u2010in\u2010valve reimplantation. Aortic regurgitation remained severe and therefore in early 2013, we proceeded with an attempted percutaneous closure of the residual paraprosthetic leak. Using 6\u2010French femoral access and a Terumo wire, the defect was successfully crossed with a 4\u2010French Multipurpose catheter and an 8 mm Amplatzer Vascular Plug 4 device (St. Jude Medical) was deployed through this catheter, resulting in abolition of aortic regurgitation on aortography and TOE, with associated excellent clinical response. Refractory paravalvular aortic regurgitation post CoreValve implantation can be successfully treated using the Amplatzer Vascular Plug 4 device. \u00a9 2013 Wiley Periodicals, Inc.<\/jats:p>","DOI":"10.1002\/ccd.25254","type":"journal-article","created":{"date-parts":[[2013,10,15]],"date-time":"2013-10-15T17:06:35Z","timestamp":1381856795000},"page":"155-159","source":"Crossref","is-referenced-by-count":5,"title":["Paravalvular leak closure for persisting aortic regurgitation after implantation of the corevalve transcatheter valve"],"prefix":"10.1002","volume":"84","author":[{"given":"Petra","family":"Poliacikova","sequence":"first","affiliation":[{"name":"Sussex Cardiac Centre, Brighton and Sussex University Hospitals NHS Trust Brighton United Kingdom"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Hildick\u2010Smith","sequence":"additional","affiliation":[{"name":"Sussex Cardiac Centre, Brighton and Sussex University Hospitals NHS Trust Brighton United Kingdom"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2013,12,24]]},"reference":[{"key":"e_1_2_5_2_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1103510"},{"key":"e_1_2_5_3_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1008232"},{"key":"e_1_2_5_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2011.08.050"},{"key":"e_1_2_5_5_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1200384"},{"key":"e_1_2_5_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2013.01.047"},{"key":"e_1_2_5_7_1","doi-asserted-by":"publisher","DOI":"10.4244\/EIJV8SQA7"},{"key":"e_1_2_5_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2013.02.088"},{"key":"e_1_2_5_9_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.22399"},{"key":"e_1_2_5_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2012.02.010"},{"key":"e_1_2_5_11_1","first-page":"92","article-title":"Percutaneous closure of paravalvular leaks after transcatheter aortic valve implantation with Edwards SAPIEN prosthesis: A report of two cases","volume":"25","author":"Est\u00e9vez\u2010Loureiro R","year":"2013","journal-title":"J Invasive Cardiol."},{"key":"e_1_2_5_12_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.21777"},{"key":"e_1_2_5_13_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.21043"},{"key":"e_1_2_5_14_1","doi-asserted-by":"publisher","DOI":"10.1093\/ejechocard\/jer086"},{"key":"e_1_2_5_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2010.04.013"},{"key":"e_1_2_5_16_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.24482"},{"key":"e_1_2_5_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2011.03.074"},{"key":"e_1_2_5_18_1","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehs120"},{"key":"e_1_2_5_19_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.24477"},{"key":"e_1_2_5_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2012.08.026"}],"container-title":["Catheterization and Cardiovascular Interventions"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fccd.25254","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ccd.25254","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/ccd.25254","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ccd.25254","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,29]],"date-time":"2023-08-29T11:14:49Z","timestamp":1693307689000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ccd.25254"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,12,24]]},"references-count":19,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2014,7]]}},"alternative-id":["10.1002\/ccd.25254"],"URL":"https:\/\/doi.org\/10.1002\/ccd.25254","archive":["Portico"],"relation":{},"ISSN":["1522-1946","1522-726X"],"issn-type":[{"value":"1522-1946","type":"print"},{"value":"1522-726X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,12,24]]}}}