{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T01:28:22Z","timestamp":1788917302716,"version":"build-2803163510"},"reference-count":22,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2014,5,26]],"date-time":"2014-05-26T00:00:00Z","timestamp":1401062400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Cathet Cardio Intervent"],"published-print":{"date-parts":[[2015,2]]},"abstract":"<jats:sec><jats:title>Introduction<\/jats:title><jats:p>Balloon expandable stents are an integral part in the catheter treatment of congenital heart disease. In the growing child, stents require dilatation to greater diameters over time. The Cook Formula stent is a recent 316 stainless steel open\u2010cell design licensed for peripheral vascular work.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Following extensive ex vivo studies, 112 stents were implanted in 97 children [median age 3.9 (0.01\u201317.6) years; median weight 13.7 (2.4\u201362.8) kg] over a 27\u2010month (Oct 2011\u2013Dec 2013) period.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Bench testing revealed that there was no stent shortening for dilatation to nominal diameter and beyond. The 5 mm stents could be dilated up to 10 mm, and the 10 mm stents to 20 mm. Stents were implanted through 4\u20137F sheaths or guide catheters over appropriate wires. Stent tracking and delivery was excellent. Twenty\u2010three stents were implanted in the right ventricular outflow tract in Fallot\u2010type lesions, 53 for branch pulmonary artery stenosis (22 post cavopulmonary shunt\/Fontan), 14 conduit stenosis, 13 Fontan fenestrations, 3 PDA in hybrid stage I Norwood, 5 in coarctation, and 1 for SVC obstruction. Sixty\u2010one stents (54%) were overdilated. There were no stent fractures. Radial strength was very good, whereas stent conformability was limited.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>The Cook Formula stent is a premounted balloon\u2010expandable stent that can be significantly overdilated with virtually no shortening allowing for precise placement and minimal protrusion into adjacent vessels. The Formula stent is a very versatile addition to the range of stents for use in the catheter treatment of complex congenital heart disease in children. \u00a9 2014 Wiley Periodicals, Inc.<\/jats:p><\/jats:sec>","DOI":"10.1002\/ccd.25543","type":"journal-article","created":{"date-parts":[[2014,5,14]],"date-time":"2014-05-14T09:49:50Z","timestamp":1400060990000},"page":"259-266","source":"Crossref","is-referenced-by-count":28,"title":["Initial experience with the cook formula balloon expandable stent in congenital heart disease"],"prefix":"10.1002","volume":"85","author":[{"given":"Daniel","family":"Quandt","sequence":"first","affiliation":[{"name":"The Heart Unit Birmingham Children's Hospital Birmingham United Kingdom"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bharat","family":"Ramchandani","sequence":"additional","affiliation":[{"name":"The Heart Unit Birmingham Children's Hospital Birmingham United Kingdom"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vinay","family":"Bhole","sequence":"additional","affiliation":[{"name":"The Heart Unit Birmingham Children's Hospital Birmingham United Kingdom"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gemma","family":"Penford","sequence":"additional","affiliation":[{"name":"The Heart Unit Birmingham Children's Hospital Birmingham United Kingdom"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chetan","family":"Mehta","sequence":"additional","affiliation":[{"name":"The Heart Unit Birmingham Children's Hospital Birmingham United Kingdom"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rami","family":"Dhillon","sequence":"additional","affiliation":[{"name":"The Heart Unit Birmingham Children's Hospital Birmingham United Kingdom"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Oliver","family":"Stumper","sequence":"additional","affiliation":[{"name":"The Heart Unit Birmingham Children's Hospital Birmingham United Kingdom"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2014,5,26]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1097\/00001573-200103000-00002"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.10342"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.4103\/0974-2069.52802"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8183.1995.tb00576.x"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.83.6.1923"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.67.3.211"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.88.2.605"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(93)90791-X"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8183.1995.tb00929.x"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.22523"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8183.2012.00764.x"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.72.4.378"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8183.2012.00765.x"},{"issue":"5","key":"e_1_2_7_15_1","first-page":"67","article-title":"RX Herculink Elite(\u00ae) renal stent system: A review of its use for the treatment of renal artery stenosis","volume":"2012","author":"Colyer WR","journal-title":"Med Devices (Auckl)"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.24481"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.22096"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.24505"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.24899"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2011.11.002"},{"key":"e_1_2_7_21_1","unstructured":"Formula Booklet Marketing Piece Cook Medical (cookmedical. com) 2013."},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.1136\/heartjnl-2013-304155"},{"key":"e_1_2_7_23_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00270-003-4600-y"}],"container-title":["Catheterization and Cardiovascular Interventions"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fccd.25543","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ccd.25543","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/ccd.25543","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ccd.25543","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,6]],"date-time":"2023-10-06T05:43:47Z","timestamp":1696571027000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ccd.25543"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,5,26]]},"references-count":22,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2015,2]]}},"alternative-id":["10.1002\/ccd.25543"],"URL":"https:\/\/doi.org\/10.1002\/ccd.25543","archive":["Portico"],"relation":{},"ISSN":["1522-1946","1522-726X"],"issn-type":[{"value":"1522-1946","type":"print"},{"value":"1522-726X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,5,26]]}}}