{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,25]],"date-time":"2026-01-25T04:54:14Z","timestamp":1769316854036,"version":"3.49.0"},"reference-count":21,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2017,3,4]],"date-time":"2017-03-04T00:00:00Z","timestamp":1488585600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"DOI":"10.13039\/100006279","name":"St. Jude Medical","doi-asserted-by":"publisher","award":["NA"],"award-info":[{"award-number":["NA"]}],"id":[{"id":"10.13039\/100006279","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Cathet Cardio Intervent"],"published-print":{"date-parts":[[2017,5]]},"abstract":"<jats:sec><jats:title>Objectives<\/jats:title><jats:p>The study purpose is to evaluate the safety and efficacy of the ADO II device for closure of patent ductus arteriosus (PDA) in children.<\/jats:p><\/jats:sec><jats:sec><jats:title>Background<\/jats:title><jats:p>Transcatheter treatment of PDA has been evolving for 40+ years and is the treatment of choice. The AMPLATZER\u2122 Duct Occluder (ADO) device was developed for larger diameter ducts and is not ideal in all PDAs. ADO II was developed for small to moderate\u2010sized ducts.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>This is a single\u2010arm, multicenter study evaluating safety and efficacy of the ADO II device. Patients &lt;18 years were screened for a PDA \u22645.5 mm in diameter and 3\u201012 mm in length. Right and left heart catheterization was performed, and hemodynamic data were obtained at the time of implant. The diameter of the left pulmonary artery (LPA) and descending aorta, and the presence of any pre\u2010existing pressure gradients across the LPA or aortic arch were assessed at baseline and 6 months post\u2010implant.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>A total of 192 patients were enrolled. The median implant time was 74 min. Median fluoroscopy time was 12 min. A retrograde (aortic) approach was used in 33% of procedures and demonstrated a statistically significant reduction in fluoroscopy time (<jats:italic>P<\/jats:italic> value\u2009=\u20090.0018) compared to an antegrade approach. The device was successfully implanted in 93% of patients, with complete closure in 98% of successful implantations.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>In this prospective study, the ADO II was safe and effective for closure of small to moderate PDAs. Implantation is simple and the ability for retrograde aortic delivery reduces procedure\u2010related radiation exposure. \u00a9 2017 Wiley Periodicals, Inc.<\/jats:p><\/jats:sec>","DOI":"10.1002\/ccd.26968","type":"journal-article","created":{"date-parts":[[2017,3,4]],"date-time":"2017-03-04T11:08:52Z","timestamp":1488625732000},"page":"1118-1128","source":"Crossref","is-referenced-by-count":22,"title":["Transcatheter closure of patent ductus arteriosus using the <scp>AMPLATZER\u2122<\/scp> duct occluder II (<scp>ADO<\/scp> II)"],"prefix":"10.1002","volume":"89","author":[{"given":"Daniel H.","family":"Gruenstein","sequence":"first","affiliation":[{"name":"Department of Pediatric Cardiology, University of Chicago Chicago Illinois"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Makram","family":"Ebeid","sequence":"additional","affiliation":[{"name":"Department of Pediatric Cardiology, University of Mississippi Medical Center Jackson Mississippi"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wolfgang","family":"Radtke","sequence":"additional","affiliation":[{"name":"Department of Pediatric Cardiology, Alfred I. duPont Hospital for Children Wilmington Delaware"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Phillip","family":"Moore","sequence":"additional","affiliation":[{"name":"Department of Pediatric Cardiology, University of California San Francisco San Francisco California"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ralf","family":"Holzer","sequence":"additional","affiliation":[{"name":"Department of Pediatric Cardiology, Sidra Medical Center Doha Qatar"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Henri","family":"Justino","sequence":"additional","affiliation":[{"name":"Department of Pediatric Cardiology, Texas Children's Hospital and Baylor College of Medicine Houston Texas"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2017,3,4]]},"reference":[{"key":"e_1_2_6_2_1","first-page":"199","article-title":"Der verschluss des Ductus arteriosus persistens ohne Thorakotomie. (vorl\u00e4ufige Mittelung)","volume":"15","author":"Porstmann W","year":"1967","journal-title":"Thoraxchir Vask Chir"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0033-8389(22)01768-7"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF02307335"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.75.3.583"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(92)90514-Y"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8183.2001.tb00708.x"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1253\/circj.CJ-09-0473"},{"key":"e_1_2_6_9_1","first-page":"258","article-title":"The Amplatzer duct occluder: Experience in 209 patients","volume":"37","author":"Bilkis AA","year":"2001","journal-title":"JAC"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(98)00013-8"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.22059"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.24768"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00246-012-0393-6"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ahj.2008.08.001"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8183.2009.00504.x"},{"key":"e_1_2_6_16_1","first-page":"401","article-title":"Initial experience with the new Amplatzer Duct Occluder II","volume":"21","author":"Dua J","year":"2009","journal-title":"J Invasive Cardiol"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.22095"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.22055"},{"key":"e_1_2_6_19_1","unstructured":"St. Jude Medical. Closure Of Patent Ductus Arteriosus With the AMPLATZER Duct Occluder. In:Clinicaltrial.gov. Bethesda (MD): National Library of Medicine (US). [cited 2016 Oct 28]. Available from:https:\/\/clinicaltrials.gov\/ct2\/show\/study\/NCT00583596"},{"key":"e_1_2_6_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(89)90064-7"},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.2004.035147"},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2008.04.013"}],"container-title":["Catheterization and Cardiovascular Interventions"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fccd.26968","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ccd.26968","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,6]],"date-time":"2023-10-06T15:05:32Z","timestamp":1696604732000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ccd.26968"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,3,4]]},"references-count":21,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2017,5]]}},"alternative-id":["10.1002\/ccd.26968"],"URL":"https:\/\/doi.org\/10.1002\/ccd.26968","archive":["Portico"],"relation":{},"ISSN":["1522-1946","1522-726X"],"issn-type":[{"value":"1522-1946","type":"print"},{"value":"1522-726X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,3,4]]}}}