{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T14:50:43Z","timestamp":1790175043241,"version":"4.1.0"},"reference-count":14,"publisher":"Wiley","issue":"7","license":[{"start":{"date-parts":[[2017,9,1]],"date-time":"2017-09-01T00:00:00Z","timestamp":1504224000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Cathet Cardio Intervent"],"published-print":{"date-parts":[[2018,6]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Objectives<\/jats:title><jats:p>We aimed to measure the reduction in the estimated dose of radiation received by patients that can be achieved using dose\u2010reduction technology (ClarityIQ, Philips Healthcare, The Netherlands), among all patients undergoing invasive cardiology procedures.<\/jats:p><\/jats:sec><jats:sec><jats:title>Background<\/jats:title><jats:p>Medical procedures remain the primary source of exposure to ionizing radiation in the general population.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>The study population comprised all patients (without exclusion criteria) undergoing invasive coronary procedures over a 1\u2010year study period in a large referral centre equipped with two catheterization laboratories (cathlabs). Both cathlabs (A and B) were equipped with the Allura Xper FD10 imaging system (Philips Healthcare, The Netherlands), but only Cathlab B was equipped with ClarityIQ technology. The primary endpoint was the estimated total dose of radiation received by the patient, as assessed by Air Kerma (AK) and dose area product (DAP).<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>In total, 2095 invasive coronary procedures were analyzed. The patients who underwent procedures in Cathlab B received an average estimated dose that was 23% (AK) and 43% (DAP) lower than the dose received by patients undergoing procedures in Cathlab A (<jats:italic>P<\/jats:italic>\u2009&lt;\u2009.0001). The reduction remained significant by multivariate analysis after adjustment for total X\u2010ray time, body mass index, arterial approach, PCI of at least one lesion, sex, and patient age.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>In our study, the ClarityIQ technology reduced the estimated radiation dose received by patients by 23\u201043%, according to the method of measurement.<\/jats:p><\/jats:sec>","DOI":"10.1002\/ccd.27245","type":"journal-article","created":{"date-parts":[[2017,9,1]],"date-time":"2017-09-01T10:52:44Z","timestamp":1504263164000},"page":"1194-1199","source":"Crossref","is-referenced-by-count":7,"title":["Minimizing exposure to radiation in invasive cardiology using modern dose\u2010reduction technology: Evaluation of the real\u2010life effects"],"prefix":"10.1002","volume":"91","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2161-4653","authenticated-orcid":false,"given":"Laurent","family":"Faroux","sequence":"first","affiliation":[{"name":"Department of Cardiology Reims University Hospital Reims France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thierry","family":"Blanpain","sequence":"additional","affiliation":[{"name":"Department of Cardiology Reims University Hospital Reims France"},{"name":"Department of Radiation Protection Reims University Hospital Reims France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pierre","family":"Nazeyrollas","sequence":"additional","affiliation":[{"name":"Department of Cardiology Reims University Hospital Reims France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sophie","family":"Tassan\u2010Mangina","sequence":"additional","affiliation":[{"name":"Department of Cardiology Reims University Hospital Reims France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Beno\u00eet","family":"Herce","sequence":"additional","affiliation":[{"name":"Department of Cardiology Reims University Hospital Reims France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christophe","family":"Tourneux","sequence":"additional","affiliation":[{"name":"Department of Radiation Protection Reims University Hospital Reims France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Damien","family":"Metz","sequence":"additional","affiliation":[{"name":"Department of Cardiology Reims University Hospital Reims France"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2017,9]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.13121262"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00247-006-0194-2"},{"key":"e_1_2_8_4_1","unstructured":"EtardC Sinno\u2010TellierS AubertB.Exposition de la population fran\u00e7aise aux rayonnements ionisants li\u00e9e aux actes de diagnostic m\u00e9dical en2007.Institut de veille sanitaire;http:\/\/www.irsn.fr\/FR\/Documents\/RA2010\/IRSN_INVS_Rapport_Expri_032010.pdf"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12471-015-0742-1"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.25913"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2016.05.011"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00380-015-0667-z"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvir.2011.09.004"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.0000157946.29224.5D"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(15)00305-0"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.26007"},{"key":"e_1_2_8_13_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.25959"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/eut409"},{"key":"e_1_2_8_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2013.12.203"}],"container-title":["Catheterization and Cardiovascular Interventions"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fccd.27245","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ccd.27245","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,23]],"date-time":"2023-09-23T21:01:21Z","timestamp":1695502881000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ccd.27245"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,9]]},"references-count":14,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2018,6]]}},"alternative-id":["10.1002\/ccd.27245"],"URL":"https:\/\/doi.org\/10.1002\/ccd.27245","archive":["Portico"],"relation":{},"ISSN":["1522-1946","1522-726X"],"issn-type":[{"value":"1522-1946","type":"print"},{"value":"1522-726X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,9]]}}}