{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T22:38:16Z","timestamp":1761863896564,"version":"3.40.5"},"reference-count":10,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2018,10,30]],"date-time":"2018-10-30T00:00:00Z","timestamp":1540857600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Cathet Cardio Intervent"],"published-print":{"date-parts":[[2019,2,15]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Transcatheter aortic valve replacement has become a mainstay alternative to surgical aortic valve replacement in patients with severe aortic stenosis at high and intermediate surgical risk. Two commercially approved valves are available in the United States: balloon\u2010expandable and self\u2010expanding. We report here a rare complication of a self\u2010expanding Evolut PRO (Medtronic, Minneapolis, Minnesota) valve failing to expand due to nitinol frame infolding. This results in a malopposed valve with a severe paravalvular leak, even though treated successfully with balloon valvuloplasty. It is important to recognize the characteristic angiographic signature of this complication\u2014the \u201cstraight line\u201d sign\u2014and how to avoid this potentially serious complication by balloon valvuloplasty or by recapture and deployment of a new valve.<\/jats:p>","DOI":"10.1002\/ccd.27870","type":"journal-article","created":{"date-parts":[[2018,10,31]],"date-time":"2018-10-31T04:11:21Z","timestamp":1540959081000},"page":"555-558","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["A word of caution using self\u2010expanding transcatheter aortic valve\u2010frame infolding"],"prefix":"10.1002","volume":"93","author":[{"given":"Itsik","family":"Ben\u2010Dor","sequence":"first","affiliation":[{"name":"Division of Cardiology MedStar Washington Hospital Center  Washington District of Columbia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toby","family":"Rogers","sequence":"additional","affiliation":[{"name":"Division of Cardiology MedStar Washington Hospital Center  Washington District of Columbia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6446-2683","authenticated-orcid":false,"given":"Lowell F.","family":"Satler","sequence":"additional","affiliation":[{"name":"Division of Cardiology MedStar Washington Hospital Center  Washington District of Columbia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4063-9226","authenticated-orcid":false,"given":"Ron","family":"Waksman","sequence":"additional","affiliation":[{"name":"Division of Cardiology MedStar Washington Hospital Center  Washington District of Columbia"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2018,10,30]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehy244"},{"issue":"5","key":"e_1_2_7_3_1","doi-asserted-by":"crossref","first-page":"e0196877","DOI":"10.1371\/journal.pone.0196877","article-title":"Transcatheter aortic valve implantation for aortic stenosis in high surgical risk patients: A systematic review and meta\u2010analysis","volume":"13","author":"Liu Z","year":"2018","journal-title":"PLoS One"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.26265"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2012.07.014"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2013.05.032"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2017.11.040"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijcard.2013.04.021"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCINTERVENTIONS.117.005923"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvscit.2017.04.008"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2008.12.007"}],"container-title":["Catheterization and Cardiovascular Interventions"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fccd.27870","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ccd.27870","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,14]],"date-time":"2023-09-14T05:53:21Z","timestamp":1694670801000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ccd.27870"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,10,30]]},"references-count":10,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2019,2,15]]}},"alternative-id":["10.1002\/ccd.27870"],"URL":"https:\/\/doi.org\/10.1002\/ccd.27870","archive":["Portico"],"relation":{},"ISSN":["1522-1946","1522-726X"],"issn-type":[{"type":"print","value":"1522-1946"},{"type":"electronic","value":"1522-726X"}],"subject":[],"published":{"date-parts":[[2018,10,30]]},"assertion":[{"value":"2018-06-25","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-08-20","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-10-30","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}