{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,14]],"date-time":"2026-11-14T22:37:14Z","timestamp":1794695834387,"version":"4.9.1"},"reference-count":21,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2019,11,19]],"date-time":"2019-11-19T00:00:00Z","timestamp":1574121600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Cathet Cardio Intervent"],"published-print":{"date-parts":[[2020,2,15]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Objective<\/jats:title><jats:p>This article aims to describe the feasibility of a novel application of the Diabolo stent technique for percutaneous downsizing of systemic\u2010to\u2010pulmonary artery shunts in patients with pulmonary overcirculation.<\/jats:p><\/jats:sec><jats:sec><jats:title>Background<\/jats:title><jats:p>Pulmonary overcirculation can lead to systemic hypoperfusion, impaired systemic oxygen delivery, and hemodynamic instability especially in patients with single\u2010ventricle physiology. Different medical and surgical strategies to treat pulmonary overcirculation have been reported so far, but no percutaneous approach amenable to further adjustment over time has been described.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Retrospective review of patients who underwent percutaneous intraluminal reduction of a systemic\u2010to\u2010pulmonary artery shunt with a covered stent in a Diabolo \u201chour\u2010glass\u201d configuration.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>From July 2018 to February 4, 2019, consecutive patients underwent trans\u2010catheter downsizing of a systemic\u2010to\u2010pulmonary artery shunt. The median age was 3.3\u2009years (range 0.7\u20135.7\u2009years). All patients had symptomatic pulmonary overflow despite maximal medical therapy. All patients underwent successful implantation of a covered stent in a Diabolo \u201chour\u2010glass\u201d configuration without any complications. Successful reduction in pulmonary overcirculation was noted in all patients with a decrease of mean pulmonary artery pressure from a median of 29\u2009mmHg (range 25\u201332\u2009mmHg) to a median of 21\u2009mmHg (range 14\u201327\u2009mmHg).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>Percutaneous intraluminal downsizing of systemic\u2010to\u2010pulmonary artery shunts with a covered stent in a Diabolo configuration is safe and feasible. With this technique, the pulmonary blood flow can be adjusted in a physiologic closed\u2010chest condition and further regulated over time.<\/jats:p><\/jats:sec>","DOI":"10.1002\/ccd.28598","type":"journal-article","created":{"date-parts":[[2019,11,19]],"date-time":"2019-11-19T18:57:30Z","timestamp":1574189850000},"page":"471-476","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Percutaneous intraluminal downsizing of systemic\u2010to\u2010pulmonary artery shunts: a novel application of the Diabolo stent technique\u2014Case series and description of the technique"],"prefix":"10.1002","volume":"95","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5468-3658","authenticated-orcid":false,"given":"Nicola","family":"Maschietto","sequence":"first","affiliation":[{"name":"Department of Cardiology Boston Children's Hospital and Harvard Medical School  Boston Massachusetts"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher","family":"Baird","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery Boston Children's Hospital and Harvard Medical School  Boston Massachusetts"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0066-3712","authenticated-orcid":false,"given":"Diego","family":"Porras","sequence":"additional","affiliation":[{"name":"Department of Cardiology Boston Children's Hospital and Harvard Medical School  Boston Massachusetts"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2019,11,19]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.1097\/PCC.0000000000000783"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1747-0803.2012.00710.x"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1093\/ejcts\/ezt172"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2005.12.028"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1136\/heart.89.10.1227"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00246-015-1339-6"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.semtcvs.2018.02.001"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.1152\/ajpheart.2001.280.5.H2076"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1067\/mtc.2003.86"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2010.10.033"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(99)00819-X"},{"key":"e_1_2_8_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(01)02664-9"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejcts.2005.11.018"},{"key":"e_1_2_8_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(02)03589-0"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2016.07.081"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.20604"},{"key":"e_1_2_8_18_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.22661"},{"issue":"2","key":"e_1_2_8_19_1","first-page":"164","article-title":"A case of percutaneous modified Blalock\u2010Taussig shunt downsize with multiple stent\u2010in\u2010graft technique","volume":"12","author":"Fiszer R","year":"2016","journal-title":"Postepy Kardiologii Interwencyjnej"},{"key":"e_1_2_8_20_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.24737"},{"key":"e_1_2_8_21_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCINTERVENTIONS.115.003003"},{"key":"e_1_2_8_22_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.27481"}],"container-title":["Catheterization and Cardiovascular Interventions"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fccd.28598","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ccd.28598","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/ccd.28598","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ccd.28598","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,7]],"date-time":"2023-09-07T14:55:18Z","timestamp":1694098518000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ccd.28598"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,11,19]]},"references-count":21,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2020,2,15]]}},"alternative-id":["10.1002\/ccd.28598"],"URL":"https:\/\/doi.org\/10.1002\/ccd.28598","archive":["Portico"],"relation":{},"ISSN":["1522-1946","1522-726X"],"issn-type":[{"value":"1522-1946","type":"print"},{"value":"1522-726X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,11,19]]},"assertion":[{"value":"2019-04-27","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-11-06","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-11-19","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}