{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T22:43:52Z","timestamp":1761864232555,"version":"3.40.5"},"reference-count":17,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2021,1,23]],"date-time":"2021-01-23T00:00:00Z","timestamp":1611360000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Cathet Cardio Intervent"],"published-print":{"date-parts":[[2021,8]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Transcatheter aortic valve replacement (TAVR) for transcatheter heart valve failure has been suggested for high\u2010risk patients. TAVR\u2010in\u2010TAVR, however, may lead to complex leaflet interactions causing coronary ostial obstruction, which is a devastating complication. Coronary protection with provisional stent placement may be challenging. We describe the first percutaneous transaxillary case of TAVR\u2010in\u2010TAVR with Bioprosthetic Aortic Scallop Intentional Laceration to prevent Iatrogenic Coronary Artery obstruction (BASILICA) where guide catheters used for coronary protection were entrapped between the valve frames. We describe anatomical predictors and management considerations. Operators should be aware of this important complication during TAVR\u2010in\u2010TAVR valve placement.<\/jats:p>","DOI":"10.1002\/ccd.29485","type":"journal-article","created":{"date-parts":[[2021,1,23]],"date-time":"2021-01-23T09:25:49Z","timestamp":1611393949000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Equipment entrapment during redo\u2010TAVR with successful BASILICA procedure"],"prefix":"10.1002","volume":"98","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5189-4417","authenticated-orcid":false,"given":"Waqas T.","family":"Qureshi","sequence":"first","affiliation":[{"name":"Division of Cardiovascular Medicine University of Massachusetts Medical School  Worcester Massachusetts USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3772-3742","authenticated-orcid":false,"given":"Matthew","family":"Parker","sequence":"additional","affiliation":[{"name":"Division of Cardiovascular Medicine University of Massachusetts Medical School  Worcester Massachusetts USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jennifer","family":"Walker","sequence":"additional","affiliation":[{"name":"Division of Cardiothoracic Surgery University of Massachusetts Medical School  Worcester Massachusetts USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2289-7598","authenticated-orcid":false,"given":"Nikolaos","family":"Kakouros","sequence":"additional","affiliation":[{"name":"Division of Cardiovascular Medicine University of Massachusetts Medical School  Worcester Massachusetts USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2021,1,23]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2015.08.012"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.26982"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2018.01.247"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.acra.2020.08.027"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.jvca.2017.08.022"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.4244\/EIJ-D-19-00056"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1080\/24748706.2020.1825888"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1161\/JAHA.117.008440"},{"key":"e_1_2_7_10_1","unstructured":"PibarotP.Incidence predictors and outcomes of structural valve deterioration in transcatheter versus surgical aortic valve deterioration: 5\u2010year follow\u2010up from the PARTNER 2 trials. Paper presented at: PCR London Valves; 2019; London UK"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2016.12.011"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9343(68)90099-5"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2019.11.024"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCINTERVENTIONS.116.003930"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2019.04.052"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2019.03.035"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2019.10.010"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCINTERVENTIONS.118.006730"}],"container-title":["Catheterization and Cardiovascular Interventions"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ccd.29485","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/ccd.29485","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ccd.29485","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,29]],"date-time":"2023-08-29T20:45:07Z","timestamp":1693341907000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ccd.29485"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,23]]},"references-count":17,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2021,8]]}},"alternative-id":["10.1002\/ccd.29485"],"URL":"https:\/\/doi.org\/10.1002\/ccd.29485","archive":["Portico"],"relation":{},"ISSN":["1522-1946","1522-726X"],"issn-type":[{"type":"print","value":"1522-1946"},{"type":"electronic","value":"1522-726X"}],"subject":[],"published":{"date-parts":[[2021,1,23]]},"assertion":[{"value":"2020-10-26","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-01-08","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-01-23","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}