{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,13]],"date-time":"2025-05-13T14:41:32Z","timestamp":1747147292591,"version":"3.40.5"},"reference-count":12,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2021,8,14]],"date-time":"2021-08-14T00:00:00Z","timestamp":1628899200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Cathet Cardio Intervent"],"published-print":{"date-parts":[[2021,11,15]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Crossover balloon occlusion technique (CBOT) has been proposed to ensure adequate closure of the arterial access used for transcatheter aortic valve replacement (TAVR). However, the CBOT performed through the contralateral femoral artery could be challenging in cases of excessively tortuous and calcified vessels or in the presence of narrow iliac carina angles. We describe a novel technique to facilitate the advancement the peripheral balloon through the contralateral femoral artery up to the target iliofemoral system in order to facilitate access site hemostasis. The present \u201clocking and drugging\u201d technique takes advantages from two mechanical aspects: (a) the locking of the 0.018\u2033 wire between the vessel wall and the TAVR delivery system or the dedicated sheath, which facilitate the crossover of the balloon in the contralateral iliofemoral system, preventing its prolapse into the aorta at the carina level and (b) the dragging of the balloon advanced into the contralateral iliofemoral system during the retrieve of the TAVR delivery system or the dedicated sheath.<\/jats:p>","DOI":"10.1002\/ccd.29915","type":"journal-article","created":{"date-parts":[[2021,8,14]],"date-time":"2021-08-14T08:09:42Z","timestamp":1628928582000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["The \u201clocking and dragging\u201d technique a facilitated crossover balloon occlusion technique for complex iliofemoral anatomy in transcatheter aortic valve replacement"],"prefix":"10.1002","volume":"98","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2105-8186","authenticated-orcid":false,"given":"Carlo","family":"Briguori","sequence":"first","affiliation":[{"name":"Interventional Cardiology Unit, Mediterranea Cardiocentro  Naples Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mario","family":"Scarpelli","sequence":"additional","affiliation":[{"name":"Interventional Cardiology Unit, Mediterranea Cardiocentro  Naples Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2021,8,14]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1814052"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1816885"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2018.12.020"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.22238"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2011.03.019"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.4244\/EIJV5I4A69"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.26371"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.24380"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2019.06.050"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.iccl.2019.08.005"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.iccl.2019.08.009"},{"key":"e_1_2_6_13_1","first-page":"283","article-title":"Transradial crossover balloon occlusion technique for primary access hemostasis during transcatheter aortic valve replacement: initial experience with the oceanus 140 cm and 200 cm balloon catheters","volume":"32","author":"Junquera L","year":"2020","journal-title":"J Invasive Cardiol"}],"container-title":["Catheterization and Cardiovascular Interventions"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ccd.29915","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/ccd.29915","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ccd.29915","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,27]],"date-time":"2023-08-27T15:20:42Z","timestamp":1693149642000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ccd.29915"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,8,14]]},"references-count":12,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2021,11,15]]}},"alternative-id":["10.1002\/ccd.29915"],"URL":"https:\/\/doi.org\/10.1002\/ccd.29915","archive":["Portico"],"relation":{},"ISSN":["1522-1946","1522-726X"],"issn-type":[{"type":"print","value":"1522-1946"},{"type":"electronic","value":"1522-726X"}],"subject":[],"published":{"date-parts":[[2021,8,14]]},"assertion":[{"value":"2021-05-04","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-08-05","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-08-14","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}