{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,9]],"date-time":"2025-09-09T22:20:35Z","timestamp":1757456435461,"version":"3.37.3"},"reference-count":27,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2022,1,27]],"date-time":"2022-01-27T00:00:00Z","timestamp":1643241600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Cathet Cardio Intervent"],"published-print":{"date-parts":[[2022,3]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>Transcatheter mitral valve repair is an increasingly used therapy for mitral regurgitation which requires fluoroscopic guidance. Limiting radiation exposure during lengthy procedures is important for both patient and operator safety. This study aimed to investigate radiation dose during contemporary use of MitraClip implantation and the effects of a dose reduction program.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>A total of 115 patients who underwent MitraClip implantation were prospectively enrolled in a single\u2010center observational study. During the inclusion period, our institution adopted a radiation dose reduction program, comprising lowering of fluoroscopy pulse rate and image target dose. The first 58 patients were treated with conventional fluoroscopy settings, while the following 57 patients underwent the procedure with the newly implemented low dose protocol.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Radiation dose area product significantly decreased after introduction of the low dose protocol (693 [366\u20131231] vs. 2265 [1517\u20133914] cGy\u00b7cm<jats:sup>2<\/jats:sup>, <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001). After correcting for fluoroscopy time, gender and body mass index, the low dose protocol emerged as a strong negative predictor of radiation dose (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001), reducing dose area product by 64% (95% confidence interval [57\u201370]). Device time, device success, and procedural safety did not differ between the normal dose and low dose group. Furthermore, the low dose protocol was not associated with an increased incidence of a combined endpoint consisting of death, repeat intervention, or heart surgery during 12 months follow\u2010up.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>Reduction of radiation exposure during transcatheter mitral valve repair by 64% is feasible without affecting procedural success or safety.<\/jats:p><\/jats:sec>","DOI":"10.1002\/ccd.30046","type":"journal-article","created":{"date-parts":[[2022,1,27]],"date-time":"2022-01-27T11:08:58Z","timestamp":1643281738000},"page":"1259-1267","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Reduction of radiation exposure during transcatheter edge\u2010to\u2010edge mitral valve repair"],"prefix":"10.1002","volume":"99","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9413-885X","authenticated-orcid":false,"given":"Michael G.","family":"Paulus","sequence":"first","affiliation":[{"name":"Department of Internal Medicine II University Hospital Regensburg Regensburg Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7086-0469","authenticated-orcid":false,"given":"Christine","family":"Meindl","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine II University Hospital Regensburg Regensburg Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Hamerle","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine II University Hospital Regensburg Regensburg Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christian","family":"Schach","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine II University Hospital Regensburg Regensburg Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lars S.","family":"Maier","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine II University Hospital Regensburg Regensburg Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kurt","family":"Debl","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine II University Hospital Regensburg Regensburg Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christoph","family":"Birner","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine I Klinikum St. Marien Amberg Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bernhard","family":"Uns\u00f6ld","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine II University Hospital Regensburg Regensburg Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2022,1,27]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/eht394"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1259\/bjr\/29507259"},{"issue":"71","key":"e_1_2_9_4_1","first-page":"e283","article-title":"2018 ACC\/HRS\/NASCI\/SCAI\/SCCT expert consensus document on optimal use of ionizing radiation in cardiovascular imaging: best practices for safety and effectiveness: a report of the American College of Cardiology Task Force on expert consensus decision pathways","volume":"2018","author":"Hirshfeld JW","journal-title":"J Am Coll Cardiol"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2013.12.062"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1806640"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hlc.2014.04.258"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2009.03.077"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.echo.2017.01.007"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.echo.2019.01.003"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2016.04.041"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/eux066"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.4244\/EIJV9I10A203"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12471-017-0992-1"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2014.02.005"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00392-015-0814-7"},{"key":"e_1_2_9_17_1","unstructured":"German Institute for Quality Assurance and Transparency in Health Care.Kathetergest\u00fctzte isolierte Mitralklappeneingriffe [Catheter\u2010based isolated mitral valve interventions].2021."},{"key":"e_1_2_9_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.echo.2007.02.003"},{"key":"e_1_2_9_19_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.29323"},{"key":"e_1_2_9_20_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCINTERVENTIONS.114.001479"},{"key":"e_1_2_9_21_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2542082312"},{"key":"e_1_2_9_22_1","unstructured":"National Research Council(U.S.). Health risks from exposure to low levels of ionizing radiation: BEIR VII Phase 2. 7 phase 2. Washington D.C: National Academies Press.2006."},{"key":"e_1_2_9_23_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00392-018-1246-y"},{"key":"e_1_2_9_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ahj.2008.08.009"},{"key":"e_1_2_9_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2018.01.024"},{"key":"e_1_2_9_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2017.01.016"},{"key":"e_1_2_9_27_1","doi-asserted-by":"publisher","DOI":"10.1093\/rpd\/nci705"},{"key":"e_1_2_9_28_1","doi-asserted-by":"publisher","DOI":"10.1093\/rpd\/ncs236"}],"container-title":["Catheterization and Cardiovascular Interventions"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ccd.30046","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/ccd.30046","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ccd.30046","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,21]],"date-time":"2023-08-21T08:48:26Z","timestamp":1692607706000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ccd.30046"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,27]]},"references-count":27,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2022,3]]}},"alternative-id":["10.1002\/ccd.30046"],"URL":"https:\/\/doi.org\/10.1002\/ccd.30046","archive":["Portico"],"relation":{},"ISSN":["1522-1946","1522-726X"],"issn-type":[{"type":"print","value":"1522-1946"},{"type":"electronic","value":"1522-726X"}],"subject":[],"published":{"date-parts":[[2022,1,27]]},"assertion":[{"value":"2021-12-01","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-12-02","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-01-27","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}