{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,27]],"date-time":"2025-05-27T13:10:10Z","timestamp":1748351410334,"version":"3.41.0"},"reference-count":19,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2024,8,1]],"date-time":"2024-08-01T00:00:00Z","timestamp":1722470400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Cathet Cardio Intervent"],"published-print":{"date-parts":[[2024,9]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>Transcatheter tricuspid valve\u2010in\u2010valve (ViV) replacement has yielded good hemodynamic outcomes in the treatment of dysfunctional bioprosthetic valves (BPVs). Intentional fracture of certain rigid BPV frames, if feasible, allows a larger implanted valve when compared with implant into an unfractured BPV. There remains limited data on the feasibility of tricuspid valve frame fracture.<\/jats:p><\/jats:sec><jats:sec><jats:title>Aims<\/jats:title><jats:p>Evaluate the feasibility of transcatheter tricuspid ViV replacement with fracture of the underlying BPV ring.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>An international multicenter registry of tricuspid ViV replacement with intentional tricuspid valve frame fracture was created. Demographic data along with procedural characteristics, outcomes, and follow\u2010up data were collected. Comparison was made to the pre\u2010 and post\u2010ViV replacement with fracture of the tricuspid valve frame conditions.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Ten patients from six centers were included with a median age and weight of 29 years and 67.3\u2009kg respectively. Tricuspid valve frame fracture was performed using a median balloon diameter 3\u2009mm (IQR 3\u20135) larger than the true inner diameter (ID). The final ID was a mean of 1.5\u2009mm (95% CI: 0.35, 2.64: <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.05), and median 1.1\u2009mm (0.5, 2.1) larger than the reported true ID of the surgical BPV after ViV replacement. The mean tricuspid inflow gradient by echocardiogram decreased by 6.65\u2009mmHg (95% CI: 4.14, 9.15: <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001). All procedures were without complication, specifically there was no heart block, pericardial effusion, or right coronary disruption.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>Intentional tricuspid valve frame fracture with tricuspid ViV replacement is feasible and can increase the valve orifice potentially reducing the risk of ViV patient prosthesis mismatch and is not associated with significant complications.<\/jats:p><\/jats:sec>","DOI":"10.1002\/ccd.31168","type":"journal-article","created":{"date-parts":[[2024,8,1]],"date-time":"2024-08-01T12:49:02Z","timestamp":1722516542000},"page":"523-530","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Feasibility of intentional bioprosthetic valve fracture in the tricuspid position"],"prefix":"10.1002","volume":"104","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3082-3609","authenticated-orcid":false,"given":"Jonathon A.","family":"Hagel","sequence":"first","affiliation":[{"name":"The Heart Institute, Cincinnati Children's Hospital University of Cincinnati Cincinnati Ohio USA"},{"name":"University of Michigan, C.S. Mott Children's Hospital Ann Arbor Michigan USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C. Huie","family":"Lin","sequence":"additional","affiliation":[{"name":"Houston Methodist DeBakey Heart and Vascular Center Houston Texas USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5992-568X","authenticated-orcid":false,"given":"Athar M.","family":"Qureshi","sequence":"additional","affiliation":[{"name":"Lillie Frank Abercrombie Section of Cardiology Texas Children's Hospital, Baylor College of Medicine Houston Texas USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1723-1254","authenticated-orcid":false,"given":"Daniel","family":"Tanase","sequence":"additional","affiliation":[{"name":"Department of Pediatric Cardiology and Congenital Heart Defects Deutsches Herzzentrum M\u00fcnchen, DHM  Munich Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andreas","family":"Eicken","sequence":"additional","affiliation":[{"name":"Department of Pediatric Cardiology and Congenital Heart Defects Deutsches Herzzentrum M\u00fcnchen, DHM  Munich Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5865-9591","authenticated-orcid":false,"given":"Jeffrey D.","family":"Zampi","sequence":"additional","affiliation":[{"name":"University of Michigan, C.S. Mott Children's Hospital Ann Arbor Michigan USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3711-0003","authenticated-orcid":false,"given":"Allison K.","family":"Cabalka","sequence":"additional","affiliation":[{"name":"Mayo Clinic College of Medicine, Department of Pediatrics Division of Structural Heart Disease Rochester Now York USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3941-0707","authenticated-orcid":false,"given":"Jason","family":"Anderson","sequence":"additional","affiliation":[{"name":"Mayo Clinic College of Medicine, Department of Pediatrics Division of Structural Heart Disease Rochester Now York USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shabana","family":"Shahanavaz","sequence":"additional","affiliation":[{"name":"The Heart Institute, Cincinnati Children's Hospital University of Cincinnati Cincinnati Ohio USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2024,8]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.115.019353"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.4103\/0974-2069.197049"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ahj.2012.02.010"},{"key":"e_1_2_10_5_1","first-page":"1","article-title":"Intentional fracture of bioprosthetic valve frames in patients undergoing valve\u2010in\u2010valve transcatheter pulmonary valve replacement","volume":"11","author":"Shahanavaz S","year":"2018","journal-title":"Circul Cardiovasc Interven"},{"key":"e_1_2_10_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijcard.2014.07.175"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2019.01.073"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.21037\/acs-2021-tviv-25"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2017.04.007"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.15420\/icr.2017:29:1"},{"key":"e_1_2_10_11_1","first-page":"1","article-title":"Expanding indications for bioprosthetic valve fracture and bioprosthetic valve remodeling: who is most likely to benefit?","volume":"11","author":"Chhatriwalla AK","year":"2018","journal-title":"Circul Cardiovasc Interven"},{"key":"e_1_2_10_12_1","first-page":"1","article-title":"Balloon fracture of a surgical mitral bioprosthesis during valve\u2010in\u2010valve transcatheter mitral valve replacement: First\u2010in\u2010Human report","volume":"11","author":"Kaneko T","year":"2018","journal-title":"Circul Cardiovasc Interven"},{"key":"e_1_2_10_13_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.28837"},{"key":"e_1_2_10_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.acvd.2014.07.051"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2016.10.036"},{"key":"e_1_2_10_16_1","first-page":"1","article-title":"Percutaneous tricuspid valve implantation","volume":"8","author":"Eicken A","year":"2015","journal-title":"Circul Cardiovasc Interven"},{"key":"e_1_2_10_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2003.10.015"},{"key":"e_1_2_10_18_1","unstructured":"CarrierM HeY PellerinM et al. 1\u2010s2.0\u2010S0003497502041620\u2010main.pdf 2003."},{"key":"e_1_2_10_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(98)01036-4"},{"key":"e_1_2_10_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2023.03.035"}],"container-title":["Catheterization and Cardiovascular Interventions"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ccd.31168","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,27]],"date-time":"2025-05-27T12:54:19Z","timestamp":1748350459000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ccd.31168"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8]]},"references-count":19,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2024,9]]}},"alternative-id":["10.1002\/ccd.31168"],"URL":"https:\/\/doi.org\/10.1002\/ccd.31168","archive":["Portico"],"relation":{},"ISSN":["1522-1946","1522-726X"],"issn-type":[{"type":"print","value":"1522-1946"},{"type":"electronic","value":"1522-726X"}],"subject":[],"published":{"date-parts":[[2024,8]]},"assertion":[{"value":"2023-11-08","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-07-20","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-08-01","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}