{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,7]],"date-time":"2026-07-07T23:58:58Z","timestamp":1783468738329,"version":"3.55.0"},"reference-count":11,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2025,3,5]],"date-time":"2025-03-05T00:00:00Z","timestamp":1741132800000},"content-version":"vor","delay-in-days":4,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100019779","name":"Qatar National Library","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100019779","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Clinical Case Reports"],"published-print":{"date-parts":[[2025,3]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:p>Hardware entrapment during percutaneous coronary intervention is a significant complication necessitating proactive anticipation by interventionists. Here we present a case of a 59\u2010year\u2010old man with a history of stent placement in LAD 1\u2009month back, who now presented with stent thrombosis and acute ST\u2010elevation MI. Percutaneous intervention was done for thrombus aspiration through the previously deployed stent, but the thrombus aspiration device (thrombuster) got stuck in the stent. Despite attempted percutaneous retrieval methods, the device remained inaccessible, leading to emergency surgical device retrieval and simultaneous coronary bypass.<\/jats:p>","DOI":"10.1002\/ccr3.70269","type":"journal-article","created":{"date-parts":[[2025,3,8]],"date-time":"2025-03-08T12:58:26Z","timestamp":1741438706000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["A Case Report of Stuck Thrombus Aspiration Catheter (Thrombuster) in Left Anterior Descending Artery of A 59\u2010Year\u2010Old Patient Undergoing PCI for Revascularization"],"prefix":"10.1002","volume":"13","author":[{"given":"Alifa","family":"Sabir","sequence":"first","affiliation":[{"name":"Rawalpindi Institute of Cardiology  Rawalpindi Pakistan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muhammad Sohail","family":"Chaudhri","sequence":"additional","affiliation":[{"name":"Rawalpindi Institute of Cardiology  Rawalpindi Pakistan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muhammad","family":"Azam","sequence":"additional","affiliation":[{"name":"Rawalpindi Institute of Cardiology  Rawalpindi Pakistan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zahid","family":"Amin","sequence":"additional","affiliation":[{"name":"Rawalpindi Institute of Cardiology  Rawalpindi Pakistan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Basam","family":"Azhar","sequence":"additional","affiliation":[{"name":"Rawalpindi Institute of Cardiology  Rawalpindi Pakistan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muhammad","family":"Ibrahim","sequence":"additional","affiliation":[{"name":"Rawalpindi Medical University  Rawalpindi Pakistan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sameen","family":"Mukhtar","sequence":"additional","affiliation":[{"name":"Dow Medical College  Karachi Pakistan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2627-685X","authenticated-orcid":false,"given":"Javed","family":"Iqbal","sequence":"additional","affiliation":[{"name":"Nursing Department Communicable Diseases Center Hamad Medical Corporation  Doha Qatar"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2025,3,5]]},"reference":[{"issue":"1","key":"e_1_2_12_2_1","article-title":"An Uncommon Case of Acute Coronary Stent Thrombosis","volume":"15","author":"Coombes K.","year":"2023","journal-title":"Cureus"},{"key":"e_1_2_12_3_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12872-020-01432-1"},{"key":"e_1_2_12_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ihj.2016.04.006"},{"issue":"5","key":"e_1_2_12_5_1","first-page":"205","article-title":"Acute Myocardial Infarction due to Late Stent Thrombosis Seventeen Months After Stent Implantation: A Case Report","volume":"45","author":"Umemura S.","year":"2005","journal-title":"Journal of Cardiology"},{"key":"e_1_2_12_6_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12928-023-00909-y"},{"key":"e_1_2_12_7_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1415098"},{"key":"e_1_2_12_8_1","doi-asserted-by":"publisher","DOI":"10.4172\/2155\u20109880.1000309"},{"key":"e_1_2_12_9_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12928-012-0151-y"},{"key":"e_1_2_12_10_1","doi-asserted-by":"publisher","DOI":"10.2174\/1573403X11309030010"},{"issue":"1","key":"e_1_2_12_11_1","article-title":"A Case Report of Broken Tip of Thrombus Aspiration Catheter (Thrombuster II) in Ectatic Left Circumflex Artery of Young Patient With Kawasaki Disease","volume":"3","author":"Oo M. M.","year":"2020","journal-title":"Journal of Cardiology Cases"},{"key":"e_1_2_12_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jsha.2014.09.001"}],"container-title":["Clinical Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ccr3.70269","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,27]],"date-time":"2025-11-27T14:16:56Z","timestamp":1764253016000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ccr3.70269"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3]]},"references-count":11,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025,3]]}},"alternative-id":["10.1002\/ccr3.70269"],"URL":"https:\/\/doi.org\/10.1002\/ccr3.70269","archive":["Portico"],"relation":{},"ISSN":["2050-0904","2050-0904"],"issn-type":[{"value":"2050-0904","type":"print"},{"value":"2050-0904","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3]]},"assertion":[{"value":"2024-07-27","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-09-16","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-03-05","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70269"}}