{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,4]],"date-time":"2026-10-04T20:54:45Z","timestamp":1791147285026,"version":"4.1.0"},"reference-count":38,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2012,10,5]],"date-time":"2012-10-05T00:00:00Z","timestamp":1349395200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Numer Methods Biomed Eng"],"published-print":{"date-parts":[[2013,2]]},"abstract":"<jats:title>SUMMARY<\/jats:title><jats:p>Patient\u2010specific modelling of abdominal aortic aneurysm has been shown to have clinical potential. This paper examines a large ruptured abdominal aortic aneurysm where the tissue from the diseased wall and the intraluminal thrombus was excised during open surgical repair and experimentally characterised. The mechanical data were used to develop material parameters that were incorporated into finite element models with measured nonuniform wall thickness. Implementation of the material data into the numerical model increased peak wall stress by 67%, wall strain by 320% and displacement by 177%, when compared with simulations based on material properties available in the literature. Distributions of numerical results were similar for both material data. Magnitudes of numerical results can differ significantly when using patient\u2010specific material properties and therefore, care should be taken when interpreting numerical results derived from population\u2010based data.Copyright \u00a9 2012 John Wiley &amp; Sons, Ltd.<\/jats:p>","DOI":"10.1002\/cnm.2515","type":"journal-article","created":{"date-parts":[[2012,10,5]],"date-time":"2012-10-05T17:57:04Z","timestamp":1349459824000},"page":"150-164","source":"Crossref","is-referenced-by-count":28,"title":["On the influence of patient\u2010specific material properties in computational simulations: A case study of a large ruptured abdominal aortic aneurysm"],"prefix":"10.1002","volume":"29","author":[{"given":"Barry J.","family":"Doyle","sequence":"first","affiliation":[{"name":"Centre for Applied Biomedical Engineering Research (CABER), Department of Mechanical, Aeronautical and Biomedical Engineering, and Materials and Surface Science Institute University of Limerick  Ireland"},{"name":"Medical Physics The University of Edinburgh  UK"},{"name":"Centre for Cardiovascular Science The University of Edinburgh  UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anthony","family":"Callanan","sequence":"additional","affiliation":[{"name":"Centre for Applied Biomedical Engineering Research (CABER), Department of Mechanical, Aeronautical and Biomedical Engineering, and Materials and Surface Science Institute University of Limerick  Ireland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pierce A.","family":"Grace","sequence":"additional","affiliation":[{"name":"Department of Vascular Surgery HSE Midwestern Regional Hospital  Limerick Ireland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eamon G.","family":"Kavanagh","sequence":"additional","affiliation":[{"name":"Department of Vascular Surgery HSE Midwestern Regional Hospital  Limerick Ireland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2012,10,5]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1067\/mva.2002.125478"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1067\/mva.2003.213"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1067\/mva.2000.103971"},{"key":"e_1_2_7_5_1","first-page":"11","article-title":"A biomechanics\u2010based rupture potential index for abdominal aortic aneurysm risk assessment","author":"Vande Geest JP","journal-title":"Annals of the New York Academy of Science"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejvs.2004.03.029"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2008.08.064"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1007\/8415_2011_70"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejvs.2010.04.003"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-010-0067-6"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.110.939819"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1186\/1475-925X-6-38"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2009.10.048"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2009.08.075"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0741-5214(00)90311-2"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1067\/mva.2002.126087"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1115\/1.2401189"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2008.01.006"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10237-010-0191-0"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF02684226"},{"key":"e_1_2_7_21_1","first-page":"475","article-title":"Toward a biomechanical tool to evaluate rupture potential of abdominal aortic aneurysm: identification of a finite strain constitutive model and evaluation of its applicability","volume":"33","author":"Raghavan ML","year":"2000","journal-title":"Journal of Vascular Surgery"},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2005.10.021"},{"key":"e_1_2_7_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2011.06.004"},{"key":"e_1_2_7_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2005.10.072"},{"key":"e_1_2_7_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2007.12.053"},{"key":"e_1_2_7_26_1","doi-asserted-by":"publisher","DOI":"10.1115\/1.1411971"},{"key":"e_1_2_7_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2008.01.036"},{"key":"e_1_2_7_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2006.05.003"},{"key":"e_1_2_7_29_1","doi-asserted-by":"publisher","DOI":"10.1114\/1.1581880"},{"key":"e_1_2_7_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2012.05.004"},{"key":"e_1_2_7_31_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-006-9132-6"},{"key":"e_1_2_7_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1078-5884(98)80031-2"},{"key":"e_1_2_7_33_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-010-0094-3"},{"key":"e_1_2_7_34_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejvs.2009.11.021"},{"key":"e_1_2_7_35_1","first-page":"161","article-title":"Autopsy study of unoperated abdominal aortic aneurysms. The case for early resection","volume":"56","author":"Darling RC","year":"1977","journal-title":"Circulation"},{"key":"e_1_2_7_36_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2004.02.025"},{"key":"e_1_2_7_37_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2011.06.113"},{"key":"e_1_2_7_38_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.22866"},{"key":"e_1_2_7_39_1","first-page":"4, IJCS_38_4_09","article-title":"A simulation of the magnetic resonance elastography steady state wave response through idealised atherosclerotic plaques","volume":"38","author":"Thomas\u2010Seale LEJ","year":"2011","journal-title":"IAENG International Journal of Computer Science"}],"container-title":["International Journal for Numerical Methods in Biomedical Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fcnm.2515","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/cnm.2515","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,11]],"date-time":"2023-09-11T03:15:20Z","timestamp":1694402120000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/cnm.2515"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,10,5]]},"references-count":38,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2013,2]]}},"alternative-id":["10.1002\/cnm.2515"],"URL":"https:\/\/doi.org\/10.1002\/cnm.2515","archive":["Portico"],"relation":{},"ISSN":["2040-7939","2040-7947"],"issn-type":[{"value":"2040-7939","type":"print"},{"value":"2040-7947","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,10,5]]}}}