{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,19]],"date-time":"2025-09-19T09:32:43Z","timestamp":1758274363049,"version":"3.41.2"},"reference-count":61,"publisher":"Wiley","issue":"12","license":[{"start":{"date-parts":[[2021,9,15]],"date-time":"2021-09-15T00:00:00Z","timestamp":1631664000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Numer Methods Biomed Eng"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Performance of the locking compression plate (LCP) is a multifactorial function. The control parameters of plating, such as geometries, material properties, and physical constraints of the LCP components, affect basic functions associated with the bone fixation, including the extent of stress shielding and subsequent bone remodeling, strength and stability of the bone\u2010LCP construct, and performance of secondary bone healing. The main objectives of this research were as follows: (1) to find the appropriate values of control parameters of an LCP construct to achieve the optimized performance throughout bone healing; and (2) to unravel relationships between LCP parameters and the LCP's performance. Different values for the plate\/screw modulus of elasticity (<jats:italic>E<\/jats:italic>), plate width (<jats:italic>W<\/jats:italic>), plate thickness (<jats:italic>T<\/jats:italic>), screw diameter (<jats:italic>D<\/jats:italic>), bone\u2010plate offset (<jats:italic>O<\/jats:italic>), and screw configuration (<jats:italic>C<\/jats:italic>), as six control parameters, were considered at five different levels. Taguchi method was adopted to create trial combinations of control parameters and determining the best set of parameters, which can optimize the overall performance of the LCP. All design cases were analyzed using the finite element method. The optimal set of control parameters consisting of 150\u2009GPa, 12\u2009mm, 4\u2009mm, 5.5\u2009mm, 2\u2009mm, and 123,678 were determined for <jats:italic>E<\/jats:italic>, <jats:italic>W<\/jats:italic>, <jats:italic>T<\/jats:italic>, <jats:italic>D<\/jats:italic>, <jats:italic>O<\/jats:italic>, and <jats:italic>C<\/jats:italic>, respectively. Furthermore, ANOVA was used to rank the most influential parameters on each function of the LCP fixation. In the overall performance of the LCP fixation, <jats:italic>E<\/jats:italic>, <jats:italic>D<\/jats:italic>, <jats:italic>T<\/jats:italic>, <jats:italic>C<\/jats:italic>, <jats:italic>W<\/jats:italic>, and <jats:italic>O<\/jats:italic> showed a contribution percentage of 46%, 22%, 10%, 11%, 8%, and 3%, respectively.<\/jats:p>","DOI":"10.1002\/cnm.3528","type":"journal-article","created":{"date-parts":[[2021,9,6]],"date-time":"2021-09-06T05:44:28Z","timestamp":1630907068000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Osteosynthesis of diaphyseal tibia fracture with locking compression plates: A numerical investigation using <scp>Taguchi<\/scp> and <scp>ANOVA<\/scp>"],"prefix":"10.1002","volume":"37","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6528-9090","authenticated-orcid":false,"given":"Yousof","family":"Mohandes","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering Ferdowsi University of Mashhad  Mashhad Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6174-2241","authenticated-orcid":false,"given":"Masoud","family":"Tahani","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering Ferdowsi University of Mashhad  Mashhad Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5592-4970","authenticated-orcid":false,"given":"Gholamreza","family":"Rouhi","sequence":"additional","affiliation":[{"name":"Faculty of Biomedical Engineering Amirkabir University of Technology  Tehran Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2021,9,15]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0020-1383(18)30294-8"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0020-1383(18)30293-6"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2003.09.021"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2003.09.020"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9290(87)90030-3"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2007.08.004"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.84B8.0841093"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.1097\/00005131-199004020-00012"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1007\/s40846-015-0066-z"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10856-011-4361-0"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10237-007-0108-8"},{"volume-title":"AO Principles of Fracture Management","year":"2000","author":"R\u00fcedi TP","key":"e_1_2_8_13_1"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.3390\/ma5010135"},{"key":"e_1_2_8_15_1","doi-asserted-by":"publisher","DOI":"10.1097\/00005131-199604000-00009"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.3390\/ma12071128"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12893-017-0244-8"},{"key":"e_1_2_8_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2015.02.006"},{"issue":"8","key":"e_1_2_8_19_1","first-page":"1","article-title":"Plating system design determines mechanical environment in long bone mid\u2010shaft fractures: a finite element analysis","volume":"33","author":"Wang J","year":"2019","journal-title":"J Invest Surg"},{"issue":"1","key":"e_1_2_8_20_1","first-page":"1","article-title":"Mechanical performance and implications on bone healing of different screw configurations for plate fixation of diaphyseal tibia fractures: a computational study","volume":"31","author":"Travascio F","year":"2020","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"e_1_2_8_21_1","doi-asserted-by":"publisher","DOI":"10.1299\/jbse.5.129"},{"key":"e_1_2_8_22_1","doi-asserted-by":"publisher","DOI":"10.1115\/1.4027669"},{"key":"e_1_2_8_23_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11517-019-02104-9"},{"key":"e_1_2_8_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.compositesb.2011.02.009"},{"key":"e_1_2_8_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.compositesb.2013.10.058"},{"key":"e_1_2_8_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2006.08.058"},{"key":"e_1_2_8_27_1","unstructured":"SynthesD.LCP Locking Compression Plate;2017.http:\/\/synthes.vo.llnwd.net\/o16\/LLNWMB8\/INT%20Mobile\/Synthes%20International\/Product%20Support%20Material\/legacy_Synthes_PDF\/DSEM-TRM-0115-0278-3_LR.pdf."},{"key":"e_1_2_8_28_1","unstructured":"InstrumentOAM.http:\/\/osvehmedical.com\/wp-content\/uploads\/2019\/08\/LCP-Plates_osveh.pdf."},{"volume-title":"Taguchi Methods: Orthogonal Arrays and Linear Graphs\u2010Tools for Quality Engineering","year":"1987","author":"Konishi S","key":"e_1_2_8_29_1"},{"key":"e_1_2_8_30_1","doi-asserted-by":"publisher","DOI":"10.1007\/s13246-015-0407-9"},{"key":"e_1_2_8_31_1","doi-asserted-by":"publisher","DOI":"10.1002\/jor.21362"},{"key":"e_1_2_8_32_1","doi-asserted-by":"publisher","DOI":"10.1002\/jor.1100070312"},{"key":"e_1_2_8_33_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199810001-00015"},{"volume-title":"AO Principles of Fracture Management: Vol. 1: Principles, Vol. 2: Specific Fractures","year":"2017","author":"Buckley RE","key":"e_1_2_8_34_1"},{"volume-title":"Mechanical Testing and Modelling of a Bone\u2010Implant Construct","year":"2012","author":"Grant C","key":"e_1_2_8_35_1"},{"key":"e_1_2_8_36_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2005.01.037"},{"key":"e_1_2_8_37_1","doi-asserted-by":"publisher","DOI":"10.1177\/0954411920985757"},{"key":"e_1_2_8_38_1","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9290(92)90056-7"},{"key":"e_1_2_8_39_1","doi-asserted-by":"publisher","DOI":"10.1038\/bonekey.2016.60"},{"key":"e_1_2_8_40_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2015.10.029"},{"key":"e_1_2_8_41_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0736-0266(03)00098-6"},{"key":"e_1_2_8_42_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.simpat.2018.01.009"},{"key":"e_1_2_8_43_1","doi-asserted-by":"publisher","DOI":"10.1080\/19443994.2015.1092893"},{"volume-title":"AO Principles of Fracture Management in the Dog and Cat","year":"2005","author":"Johnson AL","key":"e_1_2_8_44_1"},{"key":"e_1_2_8_45_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF02719191"},{"issue":"4","key":"e_1_2_8_46_1","first-page":"1086","article-title":"Design of fracture fixation plate for necessary and sufficient bone stress shielding","volume":"47","author":"Ramakrishna K","year":"2004","journal-title":"JSME Int J Ser C Mech Syst, Mach Elements Manuf"},{"key":"e_1_2_8_47_1","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9290(83)90014-3"},{"key":"e_1_2_8_48_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.compstruct.2011.05.008"},{"key":"e_1_2_8_49_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2012.07.001"},{"key":"e_1_2_8_50_1","doi-asserted-by":"publisher","DOI":"10.1115\/1.2796022"},{"key":"e_1_2_8_51_1","doi-asserted-by":"publisher","DOI":"10.4236\/jbise.2015.89055"},{"key":"e_1_2_8_52_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.compstruct.2014.08.029"},{"key":"e_1_2_8_53_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2014.11.015"},{"key":"e_1_2_8_54_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2018.04.006"},{"key":"e_1_2_8_55_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.compscitech.2018.07.039"},{"key":"e_1_2_8_56_1","doi-asserted-by":"publisher","DOI":"10.1155\/2019\/5636528"},{"key":"e_1_2_8_57_1","doi-asserted-by":"publisher","DOI":"10.1016\/0020-1383(94)90092-2"},{"key":"e_1_2_8_58_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.820231310"},{"key":"e_1_2_8_59_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtbi.2004.12.023"},{"key":"e_1_2_8_60_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0021-9290(03)00117-9"},{"key":"e_1_2_8_61_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2018.04.016"},{"key":"e_1_2_8_62_1","doi-asserted-by":"publisher","DOI":"10.1080\/1025584021000025014"}],"container-title":["International Journal for Numerical Methods in Biomedical Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/cnm.3528","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/cnm.3528","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/cnm.3528","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T06:37:41Z","timestamp":1693204661000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/cnm.3528"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,9,15]]},"references-count":61,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["10.1002\/cnm.3528"],"URL":"https:\/\/doi.org\/10.1002\/cnm.3528","archive":["Portico"],"relation":{},"ISSN":["2040-7939","2040-7947"],"issn-type":[{"type":"print","value":"2040-7939"},{"type":"electronic","value":"2040-7947"}],"subject":[],"published":{"date-parts":[[2021,9,15]]},"assertion":[{"value":"2021-07-24","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-08-29","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-09-15","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e3528"}}