{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T16:41:01Z","timestamp":1784047261371,"version":"3.55.0"},"reference-count":43,"publisher":"Wiley","issue":"10","license":[{"start":{"date-parts":[[2024,7,29]],"date-time":"2024-07-29T00:00:00Z","timestamp":1722211200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Numer Methods Biomed Eng"],"published-print":{"date-parts":[[2024,10]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Autologous arteriovenous fistula (AVF) is a commonly used vascular access (VA) for hemodialysis, and hemodynamic changes are one of the main factors for its failure. To explore the effect of geometry on the hemodynamics in the AVF, a modified model is built with a gradual and smooth turn at the anastomosis and is compared with the traditional model, which has an abrupt sharp turn at the anastomisis. Transient computational fluid dynamics (CFD) simulations were performed for the comparison and analysis of the hemodynamic fields of the two models at different stages of the pulse cycle. The results showed that the low shear stress region and high oscillatory shear stress region in the modified AVF model coincided with regions of intimal hyperplasia that have been identified by previous studies. A comparison with the blood flow velocities measured in vivo was performed, and the error between the simulation results and the medical data was reduced by 22% in the modified model, which verifies the rationality and utility of the modified model.<\/jats:p>","DOI":"10.1002\/cnm.3856","type":"journal-article","created":{"date-parts":[[2024,7,30]],"date-time":"2024-07-30T04:54:15Z","timestamp":1722315255000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Computational model\u2010based hemodynamic comparisons of traditional and modified idealized models of autologous radiocephalic fistula"],"prefix":"10.1002","volume":"40","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8626-7600","authenticated-orcid":false,"given":"Fan","family":"Wang","sequence":"first","affiliation":[{"name":"School of Quality and Technical Supervision Hebei University  Baoding Hebei China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Baohui","family":"Wang","sequence":"additional","affiliation":[{"name":"School of Quality and Technical Supervision Hebei University  Baoding Hebei China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jinfeng","family":"Guo","sequence":"additional","affiliation":[{"name":"School of Quality and Technical Supervision Hebei University  Baoding Hebei China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tian","family":"Zhang","sequence":"additional","affiliation":[{"name":"School of Quality and Technical Supervision Hebei University  Baoding Hebei China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Weina","family":"Mu","sequence":"additional","affiliation":[{"name":"School of Quality and Technical Supervision Hebei University  Baoding Hebei China"},{"name":"Ultrasonography Department Baoding No.1 Central Hospital  Baoding Hebei China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chunhui","family":"Liu","sequence":"additional","affiliation":[{"name":"Affiliated Hospital of Hebei University\/School of Clinical Medicine Hebei University  Baoding Hebei China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2024,7,29]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140\u20106736(17)30788\u20102"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.1038\/ki.2011.368"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140\u20106736(14)61601\u20109"},{"key":"e_1_2_10_5_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.ajkd.2016.02.027"},{"key":"e_1_2_10_6_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.ajkd.2007.06.008"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.avsg.2018.01.068"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.1038\/sj.ki.5001747"},{"issue":"2","key":"e_1_2_10_9_1","first-page":"150","article-title":"Biology of arteriovenous fistula failure","volume":"20","author":"Roy\u2010Chaudhury P","year":"2007","journal-title":"J Nephrol"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1115\/1.2895457"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.5301\/JVA.2011.8440"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.cma.2017.03.036"},{"key":"e_1_2_10_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2015.04.013"},{"key":"e_1_2_10_14_1","first-page":"3","article-title":"Numerical investigations of the unsteady blood flow in the end\u2010to\u2010side arteriovenous fistula for hemodialysis","volume":"18","author":"Jodko D","year":"2016","journal-title":"Acta Bioeng Biomech"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10439\u2010015\u20101525\u2010y"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.1115\/1.4043448"},{"key":"e_1_2_10_17_1","doi-asserted-by":"publisher","DOI":"10.1063\/1.4913754"},{"key":"e_1_2_10_18_1","doi-asserted-by":"publisher","DOI":"10.1007\/s13239\u2010015\u20100246\u20106"},{"key":"e_1_2_10_19_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10439\u2010015\u20101295\u20106"},{"key":"e_1_2_10_20_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12206\u2010016\u20101118\u20101"},{"key":"e_1_2_10_21_1","doi-asserted-by":"publisher","DOI":"10.1002\/cnm.3259"},{"key":"e_1_2_10_22_1","doi-asserted-by":"publisher","DOI":"10.1111\/nep.13219"},{"key":"e_1_2_10_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2012.10.027"},{"key":"e_1_2_10_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2004.12.003"},{"key":"e_1_2_10_25_1","doi-asserted-by":"publisher","DOI":"10.1088\/1402\u20104896\/abfe31"},{"key":"e_1_2_10_26_1","doi-asserted-by":"publisher","DOI":"10.1002\/htj.21902"},{"key":"e_1_2_10_27_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0165892"},{"key":"e_1_2_10_28_1","doi-asserted-by":"publisher","DOI":"10.37190\/ABB\u201001571\u20102020\u201002"},{"key":"e_1_2_10_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/0741\u20105214(86)90448\u20109"},{"key":"e_1_2_10_30_1","doi-asserted-by":"publisher","DOI":"10.3938\/jkps.63.2232"},{"key":"e_1_2_10_31_1","doi-asserted-by":"publisher","DOI":"10.3390\/dynamics1010002"},{"key":"e_1_2_10_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0021\u20109290(99)00088\u20103"},{"key":"e_1_2_10_33_1","doi-asserted-by":"publisher","DOI":"10.1093\/ndt\/gfs298"},{"key":"e_1_2_10_34_1","doi-asserted-by":"publisher","DOI":"10.1007\/s13344\u2010020\u20100042\u20104"},{"key":"e_1_2_10_35_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.bbe.2017.05.006"},{"key":"e_1_2_10_36_1","doi-asserted-by":"publisher","DOI":"10.3233\/BIR-1991-283-415"},{"key":"e_1_2_10_37_1","doi-asserted-by":"publisher","DOI":"10.1115\/1.1351807"},{"key":"e_1_2_10_38_1","doi-asserted-by":"publisher","DOI":"10.1001\/jama.282.21.2035"},{"key":"e_1_2_10_39_1","doi-asserted-by":"publisher","DOI":"10.1115\/1.4003310"},{"key":"e_1_2_10_40_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2009.10.013"},{"key":"e_1_2_10_41_1","doi-asserted-by":"publisher","DOI":"10.1115\/1.1372702"},{"key":"e_1_2_10_42_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.ATV.5.3.293"},{"key":"e_1_2_10_43_1","doi-asserted-by":"publisher","DOI":"10.1152\/physrev.00047.2009"},{"key":"e_1_2_10_44_1","doi-asserted-by":"publisher","DOI":"10.1093\/ndt\/gfr342"}],"container-title":["International Journal for Numerical Methods in Biomedical Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/cnm.3856","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,2]],"date-time":"2024-10-02T04:14:00Z","timestamp":1727842440000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/cnm.3856"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,29]]},"references-count":43,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2024,10]]}},"alternative-id":["10.1002\/cnm.3856"],"URL":"https:\/\/doi.org\/10.1002\/cnm.3856","archive":["Portico"],"relation":{},"ISSN":["2040-7939","2040-7947"],"issn-type":[{"value":"2040-7939","type":"print"},{"value":"2040-7947","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,7,29]]},"assertion":[{"value":"2023-10-25","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-07-12","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-07-29","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e3856"}}