{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,21]],"date-time":"2025-12-21T07:11:38Z","timestamp":1766301098929},"reference-count":27,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2017,8,2]],"date-time":"2017-08-02T00:00:00Z","timestamp":1501632000000},"content-version":"vor","delay-in-days":1,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["Scientific Research (C) (2) #17K11767"],"award-info":[{"award-number":["Scientific Research (C) (2) #17K11767"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clinical &amp; Exp Dental Res"],"published-print":{"date-parts":[[2017,8]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The irritation and pain associated with oral blood sampling necessary to monitor glycemic control can alter oral sensation, but no studies have measured the reliability of oral sensation testing when performed concurrently with blood sampling. The primary and secondary aims of this study were to verify the measurement reliability of current perception threshold (CPT) and pain threshold (PT) tests performed before and after blood sampling and to investigate the differences in CPTs\/PTs obtained from the oral cavity, hand, and foot, respectively. CPT\/PT measurements were obtained from the oral mucosa and the tips of fingers and toes of 18 volunteers (10 males and 8 females, average age\u00a0=\u00a026.3\u00a0years) using electrical stimulation at frequencies of 5, 250, and 2,000\u00a0Hz. Participants also provided blood samples by pricking their own index fingers with a small needle. All subjects completed the following 3 conditions at once\u2010weekly intervals as follows: (a) sensory measurements followed by blood sampling (SB block); (b) blood sampling followed by sensory measurements (BS block); (c) sensory measurements without blood sampling (CO control block). Cronbach's \u03b1 coefficients were over 0.78 for the SB, BS, and CO blocks, and are considered to be acceptable for assuring measurement reliability. The oral cavity had significantly lower CPT\/PTs than both hands and feet, such that the threshold increased in the order oral cavity\u00a0&lt;\u00a0hand\u00a0&lt;\u00a0foot. CPT and PT measurements performed concurrently with blood sampling are both reliable and region specific, and for which the oral cavity is the most sensitive testing region.<\/jats:p>","DOI":"10.1002\/cre2.75","type":"journal-article","created":{"date-parts":[[2017,8,2]],"date-time":"2017-08-02T13:46:41Z","timestamp":1501681601000},"page":"154-159","source":"Crossref","is-referenced-by-count":7,"title":["Measurement reliability of current perception threshold and pain threshold in parallel with blood sampling"],"prefix":"10.1002","volume":"3","author":[{"given":"Takahiro","family":"Ogawa","sequence":"first","affiliation":[{"name":"Removable Prosthodontics Nihon University Graduate School of Dentistry at Matsudo  Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Suguru","family":"Kimoto","sequence":"additional","affiliation":[{"name":"Department of Removable Prosthodontics Nihon University School of Dentistry at Matsudo  Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshio","family":"Nakashima","sequence":"additional","affiliation":[{"name":"Removable Prosthodontics Nihon University Graduate School of Dentistry at Matsudo  Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nobuhiko","family":"Furuse","sequence":"additional","affiliation":[{"name":"Removable Prosthodontics Nihon University Graduate School of Dentistry at Matsudo  Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masanori","family":"Ono","sequence":"additional","affiliation":[{"name":"Removable Prosthodontics Nihon University Graduate School of Dentistry at Matsudo  Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"So","family":"Furokawa","sequence":"additional","affiliation":[{"name":"Removable Prosthodontics Nihon University Graduate School of Dentistry at Matsudo  Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masakazu","family":"Okubo","sequence":"additional","affiliation":[{"name":"Department of Removable Prosthodontics Nihon University School of Dentistry at Matsudo  Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takahiro","family":"Yazaki","sequence":"additional","affiliation":[{"name":"Department of Removable Prosthodontics Nihon University School of Dentistry at Matsudo  Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasuhiko","family":"Kawai","sequence":"additional","affiliation":[{"name":"Department of Removable Prosthodontics Nihon University School of Dentistry at Matsudo  Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2017,8,2]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jaad.2013.06.055"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.314.7080.572"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.314.7080.558"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1067\/moe.2000.107536"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/0168-8227(95)01107-O"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2009.05.017"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1111\/ger.12006"},{"key":"e_1_2_7_9_1","first-page":"210","article-title":"Constant current sine wave transcutaneous nerve stimulation for the evaluation of peripheral neuropathy","volume":"68","author":"Katims J. J.","year":"1987","journal-title":"Archives of Physical Medicine and Rehabilitation"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1080\/23328940.2015.1131506"},{"key":"e_1_2_7_11_1","first-page":"286","article-title":"Reliability and characteristics of current perception thresholds in the territory of the infraorbital and inferior alveolar nerves","volume":"14","author":"Kim H. S.","year":"2000","journal-title":"Journal of Orofacial Pain"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpor.2012.09.001"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1464-5491.1991.tb02159.x"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006842-200101000-00010"},{"key":"e_1_2_7_15_1","first-page":"36","article-title":"Trends in the epidemiology of patients with diabetes in Japan","volume":"53","author":"Morimoto A.","year":"2010","journal-title":"JMAJ"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1111\/joor.12181"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1002\/cre2.14"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.dsx.2015.04.007"},{"key":"e_1_2_7_19_1","first-page":"423","article-title":"Perception thresholds for electrical stimulation of the palatal mucosa","volume":"20","author":"Ogura K.","year":"2007","journal-title":"The International Journal of Prosthodontics"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1464-5491.1994.tb00371.x"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0304-3959(99)00183-9"},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-4598(199911)22:11<1531::AID-MUS7>3.0.CO;2-O"},{"key":"e_1_2_7_23_1","doi-asserted-by":"publisher","DOI":"10.1136\/jnnp.56.4.329"},{"key":"e_1_2_7_24_1","doi-asserted-by":"publisher","DOI":"10.1590\/S1413-35552012005000083"},{"key":"e_1_2_7_25_1","doi-asserted-by":"publisher","DOI":"10.2188\/jea.10.1sup_33"},{"key":"e_1_2_7_26_1","doi-asserted-by":"publisher","DOI":"10.1177\/193229681300700510"},{"key":"e_1_2_7_27_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1464-5491.2011.03308.x"},{"key":"e_1_2_7_28_1","doi-asserted-by":"publisher","DOI":"10.1159\/000343003"}],"container-title":["Clinical and Experimental Dental Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fcre2.75","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/cre2.75","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,6]],"date-time":"2023-10-06T21:36:11Z","timestamp":1696628171000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/cre2.75"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,8]]},"references-count":27,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2017,8]]}},"alternative-id":["10.1002\/cre2.75"],"URL":"https:\/\/doi.org\/10.1002\/cre2.75","archive":["Portico"],"relation":{},"ISSN":["2057-4347","2057-4347"],"issn-type":[{"value":"2057-4347","type":"print"},{"value":"2057-4347","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,8]]}}}