{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T11:46:46Z","timestamp":1769082406936,"version":"3.49.0"},"reference-count":45,"publisher":"Oxford University Press (OUP)","issue":"6","license":[{"start":{"date-parts":[[2025,11,12]],"date-time":"2025-11-12T00:00:00Z","timestamp":1762905600000},"content-version":"vor","delay-in-days":782,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"},{"start":{"date-parts":[[2023,9,22]],"date-time":"2023-09-22T00:00:00Z","timestamp":1695340800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"funder":[{"DOI":"10.13039\/100008497","name":"Boston Scientific Corporation","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100008497","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100008497","name":"Boston Scientific Corporation","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100008497","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,12,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Aims<\/jats:title>\n                    <jats:p>The HeartLogic multisensor index has been found to be a sensitive predictor of worsening heart failure (HF). However, there is limited data on this index's association and its constituent sensors with HF readmissions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods and results<\/jats:title>\n                    <jats:p>The PREEMPT-HF study is a global, multicentre, prospective, observational, single-arm, post-market study. HF patients with an implantable defibrillator device or cardiac resynchronization therapy with defibrillator with HeartLogic capabilities were eligible if sensor data collection was turned on and the HeartLogic feature was not enabled. Thus, the HeartLogic Index\/alert and heart sounds sensor trends were unavailable via the LATITUDE remote monitoring system to clinicians (blinded). Evaluation of subject medical records at 6 months and a final in-clinic visit at 12 months was required for collection of all-cause hospitalizations and HF outpatient visits. The purpose of this study is exploratory, no formal hypothesis tests are planned, and no adjustment for multiple testing will be performed. A total of 2183 patients were enrolled at 103 sites between June 2018 and June 2020. A significant proportion of the patients were implanted with implantable defibrillator devices (39%) versus cardiac resynchronization therapy with defibrillator (61%); were female (27%); over 65 (61%); New York Heart Association class I (13%), II (53%), and III (33%); ejection fraction &amp;lt; 25% (21%); ischaemic (50%); and with a history of renal dysfunction (23%).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The PREEMPT study will provide clinical data and blinded sensor trends for the characterization of sensor changes with HF readmission, tachyarrhythmias, and event subgroups. These data may help to refine the clinical use of HeartLogic and to improve patient outcomes.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/ehf2.14469","type":"journal-article","created":{"date-parts":[[2023,9,23]],"date-time":"2023-09-23T00:42:21Z","timestamp":1695429741000},"page":"3690-3699","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["PRecision Event Monitoring for PatienTs with Heart Failure Using HeartLogic (PREEMPT-HF) Study Design and Enrolment"],"prefix":"10.1093","volume":"10","author":[{"given":"John","family":"Boehmer","sequence":"first","affiliation":[{"name":"Penn State Hershey Medical Center , Hershey, PA ,","place":["USA"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrew J.","family":"Sauer","sequence":"additional","affiliation":[{"name":"Saint Luke's Mid America Heart Institute , Kansas City, MO ,","place":["USA"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Roy","family":"Gardner","sequence":"additional","affiliation":[{"name":"Scottish National Advanced Heart Failure Service, Golden Jubilee National Hospital , Glasgow ,","place":["UK"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5725-463X","authenticated-orcid":false,"given":"Craig M.","family":"Stolen","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Boston Scientific Corporation , Marlborough, MA ,","place":["USA"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brian","family":"Kwan","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Boston Scientific Corporation , Marlborough, MA ,","place":["USA"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ramesh","family":"Wariar","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Boston Scientific Corporation , Marlborough, MA ,","place":["USA"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stephen","family":"Ruble","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Boston Scientific Corporation , Marlborough, MA ,","place":["USA"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2023,9,22]]},"reference":[{"key":"2026012113204512300_ehf214469-bib-0001","first-page":"136","article-title":"Correction: heart disease and stroke statistics-2017 update: a report from the American Heart Association (circulation (2017) 135 (e146-e603) DOI: 10.1161\/CIR.0000000000000485)","year":"2017","journal-title":"Circulation"},{"key":"2026012113204512300_ehf214469-bib-0002","doi-asserted-by":"crossref","first-page":"1123","DOI":"10.1016\/j.jacc.2013.11.053","article-title":"The global health and economic burden of hospitalizations for heart failure","volume":"63","author":"Ambrosy","year":"2014","journal-title":"J Am Coll Cardiol"},{"key":"2026012113204512300_ehf214469-bib-0003","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1016\/j.jacc.2008.10.041","article-title":"Acute heart failure syndromes","volume":"53","author":"Gheorghiade","year":"2009","journal-title":"J Am Coll Cardiol"},{"key":"2026012113204512300_ehf214469-bib-0004","doi-asserted-by":"crossref","first-page":"1122","DOI":"10.1093\/eurjhf\/hfq122","article-title":"Length of delay in seeking medical care by patients with heart failure symptoms and the role of symptom-related factors: a narrative review","volume":"12","author":"Gravely-Witte","year":"2010","journal-title":"Eur J Heart Fail"},{"key":"2026012113204512300_ehf214469-bib-0005","doi-asserted-by":"crossref","first-page":"1571","DOI":"10.1002\/ehf2.13261","article-title":"Multiparameter diagnostic sensor measurements during clinically stable periods and worsening heart failure in ambulatory patients","volume":"8","author":"Gardner","year":"2021","journal-title":"ESC Heart Fail"},{"key":"2026012113204512300_ehf214469-bib-0006","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1016\/j.jchf.2016.12.011","article-title":"A multisensor algorithm predicts heart failure events in patients with implanted devices: results from the MultiSENSE study","volume":"5","author":"Boehmer","year":"2017","journal-title":"JACC Heart Fail"},{"key":"2026012113204512300_ehf214469-bib-0007","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1002\/ehf2.12394","article-title":"Preliminary experience with the multisensor HeartLogic algorithm for heart failure monitoring: a retrospective case series report","volume":"6","author":"Capucci","year":"2019","journal-title":"ESC Heart Fail"},{"key":"2026012113204512300_ehf214469-bib-0008","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1002\/clc.23366","article-title":"Prospective evaluation of the multisensor HeartLogic algorithm for heart failure monitoring","volume":"43","author":"Santini","year":"2020","journal-title":"Clin Cardiol"},{"key":"2026012113204512300_ehf214469-bib-0009","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCHEARTFAILURE.120.008134","article-title":"Multiparametric implantable cardioverter-defibrillator algorithm for heart failure risk stratification and management: an analysis in clinical practice","volume":"14","author":"Cal\u00f2","year":"2021","journal-title":"Circ Heart Fail"},{"key":"2026012113204512300_ehf214469-bib-0010","doi-asserted-by":"crossref","first-page":"2021","DOI":"10.1161\/CIRCULATIONAHA.112.000417","article-title":"Impact of cardiac resynchronization therapy on hospitalizations in the resynchronization-defibrillation for ambulatory heart failure trial","volume":"129","author":"Gillis","year":"2014","journal-title":"Circulation"},{"key":"2026012113204512300_ehf214469-bib-0011","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCHEARTFAILURE.120.008134","article-title":"Multiparametric implantable cardioverter-defibrillator algorithm for heart failure risk stratification and management: an analysis in clinical practice","volume":"14","author":"Cal\u00f2","year":"2021","journal-title":"Circ Heart Fail"},{"key":"2026012113204512300_ehf214469-bib-0012","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1002\/clc.23366","article-title":"Prospective evaluation of the multisensor HeartLogic algorithm for heart failure monitoring","volume":"43","author":"Santini","year":"2020","journal-title":"Clin Cardiol"},{"key":"2026012113204512300_ehf214469-bib-0013","doi-asserted-by":"crossref","first-page":"398","DOI":"10.1161\/CIRCHEARTFAILURE.112.968735","article-title":"The three-phase terrain of heart failure readmissions","volume":"5","author":"Desai","year":"2012","journal-title":"Circ Heart Fail"},{"key":"2026012113204512300_ehf214469-bib-0014","doi-asserted-by":"crossref","first-page":"270","DOI":"10.1001\/jama.2017.8444","article-title":"Association of changing hospital readmission rates with mortality rates after hospital discharge","volume":"318","author":"Dharmarajan","year":"2017","journal-title":"JAMA"},{"key":"2026012113204512300_ehf214469-bib-0015","doi-asserted-by":"crossref","first-page":"1169","DOI":"10.1002\/ejhf.1212","article-title":"The hospital readmissions reduction program\u2014learning from failure of a healthcare policy","volume":"20","author":"Gupta","year":"2018","journal-title":"Eur J Heart Fail"},{"key":"2026012113204512300_ehf214469-bib-0016","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCHEARTFAILURE.121.008335","article-title":"Trends in 30- and 90-day readmission rates for heart failure","volume":"14","author":"Khan","year":"2021","journal-title":"Circ Heart Fail"},{"key":"2026012113204512300_ehf214469-bib-0017","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1016\/j.jchf.2013.01.008","article-title":"Validated, electronic health record deployable prediction models for assessing patient risk of 30-day rehospitalization and mortality in older heart failure patients","volume":"1","author":"Eapen","year":"2013","journal-title":"JACC Heart Fail"},{"key":"2026012113204512300_ehf214469-bib-0018","doi-asserted-by":"crossref","first-page":"1371","DOI":"10.1001\/archinte.168.13.1371","article-title":"Statistical models and patient predictors of readmission for heart failure: a systematic review","volume":"168","author":"Ross","year":"2008","journal-title":"Arch Intern Med"},{"key":"2026012113204512300_ehf214469-bib-0019","doi-asserted-by":"crossref","first-page":"1509","DOI":"10.1161\/CIRCULATIONAHA.116.026184","article-title":"Impact of practice-based management of pulmonary artery pressures in 2000 patients implanted with the CardioMEMS sensor","volume":"135","author":"Heywood","year":"2017","journal-title":"Circulation"},{"key":"2026012113204512300_ehf214469-bib-0020","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1007\/s10840-021-01091-y","article-title":"Heart rate score and outcomes in ICD patients: insights from the prospective randomized INTRINSIC RV trial","volume":"64","author":"Gopinathannair","year":"2022","journal-title":"J Interv Card Electrophysiol"},{"key":"2026012113204512300_ehf214469-bib-0021","doi-asserted-by":"crossref","first-page":"2266","DOI":"10.1093\/eurheartj\/ehr050","article-title":"Sensitivity and positive predictive value of implantable intrathoracic impedance monitoring as a predictor of heart failure hospitalizations: the SENSE-HF trial","volume":"32","author":"Conraads","year":"2011","journal-title":"Eur Heart J"},{"key":"2026012113204512300_ehf214469-bib-0022","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1161\/CIRCHEARTFAILURE.113.000883","article-title":"Physical activity measured with implanted devices predicts patient outcome in chronic heart failure","volume":"7","author":"Conraads","year":"2014","journal-title":"Circ Heart Fail"},{"key":"2026012113204512300_ehf214469-bib-0023","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1111\/j.1540-8167.2010.01924.x","article-title":"Temporal associations between thoracic volume overload and malignant ventricular arrhythmias: a study of intrathoracic impedance","volume":"22","author":"Ip","year":"2011","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2026012113204512300_ehf214469-bib-0024","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1111\/j.1540-8167.2010.01947.x","article-title":"OptiVol fluid index: does an association with ventricular arrhythmias hold water?","volume":"22","author":"Sullivan","year":"2011","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2026012113204512300_ehf214469-bib-0025","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1007\/s11936-008-0028-7","article-title":"Therapeutic implications of implantable device-based monitoring of patients with heart failure","volume":"10","author":"Popjies","year":"2008","journal-title":"Curr Treat Options Cardiovasc Med"},{"key":"2026012113204512300_ehf214469-bib-0026","doi-asserted-by":"crossref","first-page":"226","DOI":"10.3909\/ricm0665","article-title":"Worsening thoracic impedance as a ventricular tachyarrhythmia risk","volume":"15","author":"Abi-Saleh","year":"2014","journal-title":"Rev Cardiovasc Med"},{"key":"2026012113204512300_ehf214469-bib-0027","doi-asserted-by":"crossref","first-page":"405","DOI":"10.5603\/CJ.a2014.0022","article-title":"Trying to predict the unpredictable: variations in device-based daily monitored diagnostic parameters can predict malignant arrhythmic events in patients undergoing cardiac resynchronization therapy","volume":"21","author":"J\u0119drzejczyk-Patej","year":"2014","journal-title":"Cardiol J"},{"key":"2026012113204512300_ehf214469-bib-0028","article-title":"Heart failure diagnostic sensor measurements change during atrial arrhythmias","volume":"14","author":"Hariharan","year":"2017","journal-title":"Heart Rhythm"},{"key":"2026012113204512300_ehf214469-bib-0029","doi-asserted-by":"crossref","DOI":"10.1016\/j.cardfail.2016.06.206","article-title":"AF in HF: the chicken or the egg? Role of Crt device based sensor data in identifying a causal relationship between AF and worsening HF","volume":"22","author":"Pubbi","year":"2016","journal-title":"J Card Fail"},{"key":"2026012113204512300_ehf214469-bib-0030","article-title":"Arrhythmia burden increases prior to worsening heart failure events","volume":"14","author":"Capucci","year":"2017","journal-title":"Heart Rhythm"},{"key":"2026012113204512300_ehf214469-bib-0031","doi-asserted-by":"crossref","first-page":"1300","DOI":"10.1002\/ejhf.2285","article-title":"Vericiguat in patients with atrial fibrillation and heart failure with reduced ejection fraction: insights from the VICTORIA trial","volume":"23","author":"Ponikowski","year":"2021","journal-title":"Eur J Heart Fail"},{"key":"2026012113204512300_ehf214469-bib-0032","doi-asserted-by":"crossref","first-page":"1009","DOI":"10.1056\/NEJMoa071098","article-title":"Prognostic importance of defibrillator shocks in patients with heart failure","volume":"359","author":"Poole","year":"2008","journal-title":"N Engl J Med"},{"key":"2026012113204512300_ehf214469-bib-0033","doi-asserted-by":"crossref","first-page":"3599","DOI":"10.1093\/eurheartj\/ehab368","article-title":"2021 ESC guidelines for the diagnosis and treatment of acute and chronic heart failure","volume":"42","author":"McDonagh","year":"2021","journal-title":"Eur Heart J"},{"key":"2026012113204512300_ehf214469-bib-0034","doi-asserted-by":"crossref","first-page":"1338","DOI":"10.1002\/ejhf.1492","article-title":"Acute heart failure congestion and perfusion status \u2013 impact of the clinical classification on in-hospital and long-term outcomes; insights from the ESC-EORP-HFA heart failure long-term registry","volume":"21","author":"Chioncel","year":"2019","journal-title":"Eur J Heart Fail"},{"key":"2026012113204512300_ehf214469-bib-0035","doi-asserted-by":"crossref","first-page":"298","DOI":"10.1016\/j.jchf.2014.02.007","article-title":"Understanding the heterogeneity in volume overload and fluid distribution in decompensated heart failure is key to optimal volume management: role for blood volume quantitation","volume":"2","author":"Miller","year":"2014","journal-title":"JACC Heart Fail"},{"key":"2026012113204512300_ehf214469-bib-0036","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/j.ejim.2021.11.010","article-title":"Phenotyping congestion in patients with acutely decompensated heart failure with preserved and reduced ejection fraction: the Decongestion duRing therapY for acute decOmpensated heart failure in HFpEF vs HFrEF- DRY-OFF study","volume":"97","author":"Cogliati","year":"2022","journal-title":"Eur J Intern Med"},{"key":"2026012113204512300_ehf214469-bib-0037","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1161\/CIRCULATIONAHA.114.010637","article-title":"Phenomapping for novel classification of heart failure with preserved ejection fraction","volume":"131","author":"Shah","year":"2015","journal-title":"Circulation"},{"key":"2026012113204512300_ehf214469-bib-0038","doi-asserted-by":"crossref","DOI":"10.1001\/jama.294.15.1944","article-title":"Does this dyspneic patient in the emergency department have congestive heart failure?","volume":"294","author":"Wang","year":"2005","journal-title":"JAMA"},{"key":"2026012113204512300_ehf214469-bib-0039","article-title":"Novel findings of respiratory rate increases using the multisensor HeartLogic heart failure monitoring algorithm in COVID-19-positive patients: a case series","volume":"5","author":"Yapejian","year":"2021","journal-title":"Eur Heart J Case Rep"},{"key":"2026012113204512300_ehf214469-bib-0040","doi-asserted-by":"crossref","first-page":"1053","DOI":"10.1016\/j.jchf.2020.09.009","article-title":"Insights from HeartLogic multisensor monitoring during the COVID-19 pandemic in new York City","volume":"8","author":"Mitter","year":"2020","journal-title":"JACC Heart Fail"},{"key":"2026012113204512300_ehf214469-bib-0041","doi-asserted-by":"crossref","first-page":"2265","DOI":"10.1016\/j.jaccas.2020.09.035","article-title":"Applications of the multisensor HeartLogic heart failure monitoring algorithm during the COVID-19 global pandemic","volume":"2","author":"Egolum","year":"2020","journal-title":"JACC Case Rep"},{"key":"2026012113204512300_ehf214469-bib-0042","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1093\/eurheartj\/ehab724.0712","article-title":"HeartLogic algorithm for heart failure monitoring in the era of CoViD-19 pandemic and remote monitoring\/telemedicine","volume":"42","author":"Ebrille","year":"2021","journal-title":"Eur Heart J"},{"key":"2026012113204512300_ehf214469-bib-0043","article-title":"A steep increase in the HeartLogic index predicts COVID-19 disease in an advanced heart failure patient","volume":"2020","author":"Heggermont","year":"2020","journal-title":"Case Rep Cardiol"},{"key":"2026012113204512300_ehf214469-bib-0044","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1016\/j.cardfail.2020.12.019","article-title":"Case reports of implantable cardiac device physiologic sensor changes in subjects with coronavirus disease-2019 infection","volume":"27","author":"Shumway","year":"2021","journal-title":"J Card Fail"},{"key":"2026012113204512300_ehf214469-bib-0045","doi-asserted-by":"crossref","first-page":"4026","DOI":"10.1002\/ehf2.13500","article-title":"Multiparameter diagnostic sensor measurements in heart failure patients presenting with SARS-CoV-2 infection","volume":"8","author":"Gardner","year":"2021","journal-title":"ESC Heart Fail"}],"container-title":["ESC Heart Failure"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/eschf\/article-pdf\/10\/6\/3690\/64699327\/eschf_10_6_3690.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/eschf\/article-pdf\/10\/6\/3690\/64699327\/eschf_10_6_3690.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,21]],"date-time":"2026-01-21T18:25:14Z","timestamp":1769019914000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/eschf\/article\/10\/6\/3690\/8284355"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9,22]]},"references-count":45,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2023,9,22]]},"published-print":{"date-parts":[[2023,12,1]]}},"URL":"https:\/\/doi.org\/10.1002\/ehf2.14469","relation":{},"ISSN":["2055-5822"],"issn-type":[{"value":"2055-5822","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2023,12]]},"published":{"date-parts":[[2023,9,22]]},"assertion":[{"value":"2023-04-17","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-06-21","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-09-22","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}