{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,28]],"date-time":"2026-07-28T03:25:14Z","timestamp":1785209114962,"version":"3.55.0"},"reference-count":47,"publisher":"Oxford University Press (OUP)","issue":"4","license":[{"start":{"date-parts":[[2017,12,28]],"date-time":"2017-12-28T00:00:00Z","timestamp":1514419200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"funder":[{"DOI":"10.13039\/501100002803","name":"Fondazione Cariplo","doi-asserted-by":"publisher","award":["2011\u20132241"],"award-info":[{"award-number":["2011\u20132241"]}],"id":[{"id":"10.13039\/501100002803","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100002803","name":"Fondazione Cariplo","doi-asserted-by":"publisher","award":["2015\u20131044"],"award-info":[{"award-number":["2015\u20131044"]}],"id":[{"id":"10.13039\/501100002803","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Fondazione Cariplo e Regione Lombarida","award":["2016-0901"],"award-info":[{"award-number":["2016-0901"]}]},{"name":"National Institute of Health-National Institute of Biomedical Imaging and Bioengineering Quantum","award":["5U01EB012487-05"],"award-info":[{"award-number":["5U01EB012487-05"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,4,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Aims<\/jats:title>\n                    <jats:p>To correlate the dynamics of platelet activation with the development of thromboembolic events in patients with continuous-flow left ventricular assist device (cf-LVAD).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods and results<\/jats:title>\n                    <jats:p>The platelet activity state (PAS) assay was utilized to evaluate platelet activation in 68 cf-LVAD patients implanted with the HeartMate II (n = 15, 22%), HeartMate 3 (n = 15, 22%), or HeartWare HVAD (n = 38, 56%). PAS was measured preoperatively, early post-implant, and at long-term follow-up (1, 3, 6, 12, 18, and 24 months post-implant). PAS was also measured at the occurrence of adverse events in patients who developed thrombotic complications. Data on patient demographics, medical history, antithrombotic therapy, and coagulation parameters were also analysed. Over a median follow-up of 602 (234\u2013942) days, PAS values did not increase over time in the overall population (P = 0.15). However, PAS measured at event was 15-fold higher in the six patients (9%) who suffered pump thrombosis (n = 2) or ischaemic stroke (n = 4) vs. the rest of the population [6.67% (5.59%\u201311.98%) vs. 0.45% (0.33%\u20130.75%); P = 0.012], despite comparable coagulation profile. Pre-implant PAS values were 4.5-fold higher in these patients [1.90% (1.24%\u20133.17%) vs. 0.42% (0.32%\u20130.72%); P = 0.006]. Neither preoperative variables nor the type of the pump or the antiplatelet strategy were associated with a higher risk of complications.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Thrombotic events are associated with altered PAS values. Moreover, baseline elevated PAS values in patients who developed thrombotic events suggest patient-specific tendency to post-implant thromboembolic complications. Prospectively, systematic monitoring of PAS might guide the development of refined patient-tailored antithrombotic strategies and the technological improvement of LVAD design.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/ejhf.1113","type":"journal-article","created":{"date-parts":[[2017,12,28]],"date-time":"2017-12-28T04:26:46Z","timestamp":1514435206000},"page":"792-800","source":"Crossref","is-referenced-by-count":42,"title":["Platelet Activation is a Preoperative Risk Factor for the Development of Thromboembolic Complications in Patients with Continuous-Flow Left Ventricular Assist Device"],"prefix":"10.1093","volume":"20","author":[{"given":"Filippo","family":"Consolo","sequence":"first","affiliation":[{"name":"Universit\u00e0 Vita Salute San Raffaele , Milan ,","place":["Italy"]},{"name":"Department of Electronics, Information and Bioengineering, Politecnico di Milano , Milan ,","place":["Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giulia","family":"Sferrazza","sequence":"additional","affiliation":[{"name":"Department of Electronics, Information and Bioengineering, Politecnico di Milano , Milan ,","place":["Italy"]},{"name":"Anesthesia and Cardiothoracic Intensive Care, San Raffaele Scientific Institute , Milan ,","place":["Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giulia","family":"Motolone","sequence":"additional","affiliation":[{"name":"Department of Electronics, Information and Bioengineering, Politecnico di Milano , Milan ,","place":["Italy"]},{"name":"Anesthesia and Cardiothoracic Intensive Care, San Raffaele Scientific Institute , Milan ,","place":["Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rachele","family":"Contri","sequence":"additional","affiliation":[{"name":"Anesthesia and Cardiothoracic Intensive Care, San Raffaele Scientific Institute , Milan ,","place":["Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lorenzo","family":"Valerio","sequence":"additional","affiliation":[{"name":"Department of Electronics, Information and Bioengineering, Politecnico di Milano , Milan ,","place":["Italy"]},{"name":"Anesthesia and Cardiothoracic Intensive Care, San Raffaele Scientific Institute , Milan ,","place":["Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rosalba","family":"Lembo","sequence":"additional","affiliation":[{"name":"Anesthesia and Cardiothoracic Intensive Care, San Raffaele Scientific Institute , Milan ,","place":["Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Loris","family":"Pozzi","sequence":"additional","affiliation":[{"name":"Coagulation Service and Thrombosis Research Unit, San Raffaele Scientific Institute , Milan ,","place":["Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrizia","family":"Della Valle","sequence":"additional","affiliation":[{"name":"Coagulation Service and Thrombosis Research Unit, San Raffaele Scientific Institute , Milan ,","place":["Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michele","family":"De Bonis","sequence":"additional","affiliation":[{"name":"Cardiac Surgery, San Raffaele Scientific Institute , Milan ,","place":["Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alberto","family":"Zangrillo","sequence":"additional","affiliation":[{"name":"Universit\u00e0 Vita Salute San Raffaele , Milan ,","place":["Italy"]},{"name":"Anesthesia and Cardiothoracic Intensive Care, San Raffaele Scientific Institute , Milan ,","place":["Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gianfranco B.","family":"Fiore","sequence":"additional","affiliation":[{"name":"Department of Electronics, Information and Bioengineering, Politecnico di Milano , Milan ,","place":["Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alberto","family":"Redaelli","sequence":"additional","affiliation":[{"name":"Department of Electronics, Information and Bioengineering, Politecnico di Milano , Milan ,","place":["Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marvin J.","family":"Slepian","sequence":"additional","affiliation":[{"name":"Department of Medicine and Biomedical Engineering, Sarver Heart Center, The University of Arizona , Tucson, AZ ,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Federico","family":"Pappalardo","sequence":"additional","affiliation":[{"name":"Universit\u00e0 Vita Salute San Raffaele , Milan ,","place":["Italy"]},{"name":"Anesthesia and Cardiothoracic Intensive Care, San Raffaele Scientific Institute , Milan ,","place":["Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2017,12,28]]},"reference":[{"key":"2026011721233145000_ejhf1113-bib-0001","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1002\/ejhf.779","article-title":"Left ventricular assist device therapy in advanced heart failure: patient selection and outcomes","volume":"19","author":"Gustafsson","year":"2017","journal-title":"Eur J Heart Fail"},{"key":"2026011721233145000_ejhf1113-bib-0002","doi-asserted-by":"crossref","first-page":"1003","DOI":"10.1161\/CIRCHEARTFAILURE.114.001391","article-title":"Clinical outcomes after continuous-flow left ventricular assist device: a systematic review","volume":"7","author":"McIlvennan","year":"2014","journal-title":"Circ Heart Fail"},{"key":"2026011721233145000_ejhf1113-bib-0003","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1016\/j.jacc.2009.03.055","article-title":"Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device","volume":"54","author":"Pagani","year":"2009","journal-title":"J Am Coll Cardiol"},{"key":"2026011721233145000_ejhf1113-bib-0004","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1161\/CIRCHEARTFAILURE.111.963991","article-title":"Outcomes in advanced heart failure patients with left ventricular assist devices for destination therapy","volume":"5","author":"Park","year":"2012","journal-title":"Circ Heart Fail"},{"key":"2026011721233145000_ejhf1113-bib-0005","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1007\/s12265-009-9092-y","article-title":"Physiologic and pathologic changes in patients with continuous-flow ventricular assist devices","volume":"2","author":"John","year":"2009","journal-title":"J Cardiovasc Transl Res"},{"key":"2026011721233145000_ejhf1113-bib-0006","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1016\/j.healun.2013.12.001","article-title":"An analysis of pump thrombus events in patients in the HeartWare ADVANCE bridge to transplant and continued access protocol trial","volume":"33","author":"Najjar","year":"2014","journal-title":"J Heart Lung Transplant"},{"key":"2026011721233145000_ejhf1113-bib-0007","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1056\/NEJMoa1313385","article-title":"Unexpected abrupt increase in left ventricular assist device thrombosis","volume":"370","author":"Starling","year":"2014","journal-title":"N Engl J Med"},{"key":"2026011721233145000_ejhf1113-bib-0008","doi-asserted-by":"crossref","first-page":"1578","DOI":"10.1016\/j.healun.2015.08.017","article-title":"Adverse neurologic events in patients bridged with long-term mechanical circulatory support: a device-specific comparative analysis","volume":"34","author":"Coffin","year":"2015","journal-title":"J Heart Lung Transplant"},{"key":"2026011721233145000_ejhf1113-bib-0009","first-page":"582","article-title":"Hemorrhage and thrombosis with different LVAD technologies: a matter of flow?","volume":"3","author":"Tarzia","year":"2014","journal-title":"Ann Cardiothorac Surg"},{"key":"2026011721233145000_ejhf1113-bib-0010","doi-asserted-by":"crossref","first-page":"3038","DOI":"10.1161\/CIRCULATIONAHA.111.040246","article-title":"Bleeding and thrombosis in patients with continuous-flow ventricular assist devices","volume":"125","author":"Eckman","year":"2012","journal-title":"Circulation"},{"key":"2026011721233145000_ejhf1113-bib-0011","doi-asserted-by":"crossref","first-page":"1525","DOI":"10.1182\/blood.V88.5.1525.1525","article-title":"Platelets and shear stress","volume":"88","author":"Kroll","year":"1996","journal-title":"Blood"},{"key":"2026011721233145000_ejhf1113-bib-0012","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1111\/aor.12542","article-title":"Numerical analysis of blood damage potential of the HeartMate II and HeartWare HVAD rotary blood pumps","volume":"39","author":"Thamsen","year":"2015","journal-title":"Artif Organs"},{"key":"2026011721233145000_ejhf1113-bib-0013","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1097\/MAT.0000000000000034","article-title":"Thrombus formation patterns in the HeartMate II ventricular assist device: clinical observations can be predicted by numerical simulations","volume":"60","author":"Chiu","year":"2014","journal-title":"ASAIO J"},{"key":"2026011721233145000_ejhf1113-bib-0014","doi-asserted-by":"crossref","first-page":"1259","DOI":"10.1016\/j.athoracsur.2013.05.081","article-title":"Surgical technique influences HeartMate II left ventricular assist device thrombosis","volume":"96","author":"Taghavi","year":"2013","journal-title":"Ann Thorac Surg"},{"key":"2026011721233145000_ejhf1113-bib-0015","first-page":"513","article-title":"Mechanical circulatory support devices as destination therapy\u2014current evidence","volume":"3","author":"Puehler","year":"2014","journal-title":"Ann Cardiothorac Surg"},{"key":"2026011721233145000_ejhf1113-bib-0016","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1016\/j.jbiomech.2016.11.016","article-title":"Shear-mediated platelet activation in the free flow: perspectives on the emerging spectrum of cell mechanobiological mechanisms mediating cardiovascular implant thrombosis","volume":"50","author":"Slepian","year":"2017","journal-title":"J Biomech"},{"key":"2026011721233145000_ejhf1113-bib-0017","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1016\/j.healun.2012.09.013","article-title":"International Society for Heart and Lung Transplantation. The 2013 International Society for Heart and Lung Transplantation Guidelines for mechanical circulatory support: executive summary","volume":"32","author":"Feldman","year":"2013","journal-title":"J Heart Lung Transplant"},{"key":"2026011721233145000_ejhf1113-bib-0018","first-page":"501","article-title":"Flow-induced platelet activation in mechanical heart valves","volume":"13","author":"Bluestein","year":"2004","journal-title":"J Heart Valve Dis"},{"key":"2026011721233145000_ejhf1113-bib-0019","doi-asserted-by":"crossref","first-page":"4994","DOI":"10.1038\/s41598-017-05130-5","article-title":"High frequency components of hemodynamic shear stress profiles are a major determinant of shear-mediated platelet activation in therapeutic blood recirculating devices","volume":"7","author":"Consolo","year":"2017","journal-title":"Sci Rep"},{"key":"2026011721233145000_ejhf1113-bib-0020","doi-asserted-by":"crossref","first-page":"971","DOI":"10.1111\/aor.12672","article-title":"On the use of the platelet activity state assay for the in vitro quantification of platelet activation in blood recirculating devices for extracorporeal circulation","volume":"40","author":"Consolo","year":"2016","journal-title":"Artif Organs"},{"key":"2026011721233145000_ejhf1113-bib-0021","doi-asserted-by":"crossref","DOI":"10.1115\/1.4026254","article-title":"Thromboresistance comparison of the HeartMate II ventricular assist device with the device thrombogenicity emulation-optimized HeartAssist 5 VAD","volume":"136","author":"Chiu","year":"2014","journal-title":"J Biomech Eng"},{"key":"2026011721233145000_ejhf1113-bib-0022","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1007\/s11239-013-0997-6","article-title":"Comparative efficacy of in vitro and in vivo metabolized aspirin in the DeBakey ventricular assist device","volume":"37","author":"Sheriff","year":"2014","journal-title":"J Thromb Thrombolysis"},{"key":"2026011721233145000_ejhf1113-bib-0023","doi-asserted-by":"crossref","first-page":"788","DOI":"10.1007\/s12265-014-9596-y","article-title":"Numerical model of full-cardiac cycle hemodynamics in a total artificial heart and the effect of its size on platelet activation","volume":"7","author":"Marom","year":"2014","journal-title":"J Cardiovasc Transl Res"},{"key":"2026011721233145000_ejhf1113-bib-0024","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1016\/j.jbiomech.2012.11.032","article-title":"The Syncardia\u2122 total artificial heart: in vivo, in vitro, and computational modeling studies","volume":"46","author":"Slepian","year":"2013","journal-title":"J Biomech"},{"key":"2026011721233145000_ejhf1113-bib-0025","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1006\/abio.1999.4148","article-title":"Acetylated prothrombin as a substrate in the measurement of the procoagulant activity of platelets: elimination of the feedback activation of platelets by thrombin","volume":"272","author":"Jesty","year":"1999","journal-title":"Anal Biochem"},{"key":"2026011721233145000_ejhf1113-bib-0026","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1097\/MAT.0b013e3181fcbd86","article-title":"Thrombogenic potential of Innovia polymer valves versus Carpentier-Edwards Perimount Magna aortic bioprosthetic valves","volume":"57","author":"Claiborne","year":"2011","journal-title":"ASAIO J"},{"issue":"Suppl. 1","key":"2026011721233145000_ejhf1113-bib-0027","first-page":"1283","article-title":"Shear-mediated platelet activation (SMPA) yields a differing \u201cactivation signature\u201d than that of biochemical agonists","volume":"1","author":"Roka-Moiia","year":"2017","journal-title":"Res Pract Thromb Haemost"},{"key":"2026011721233145000_ejhf1113-bib-0028","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1080\/0953710031000092839","article-title":"Platelet activation in a circulating flow loop: combined effects of shear stress and exposure time","volume":"14","author":"Jesty","year":"2003","journal-title":"Platelets"},{"key":"2026011721233145000_ejhf1113-bib-0029","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.medengphy.2017.08.005","article-title":"Microfludic platforms for the evaluation of anti-platelet agent efficacy under hyper-shear conditions associated with ventricular assist devices","volume":"48","author":"Dimasi","year":"2017","journal-title":"Med Eng Phys"},{"key":"2026011721233145000_ejhf1113-bib-0030"},{"key":"2026011721233145000_ejhf1113-bib-0031","first-page":"1255","article-title":"Shear-mediated platelet activation in patients implanted with continuous flow LVADs: a preliminary study utilizing the platelet activity state (PAS) assay","volume":"2015","author":"Valerio","year":"2015","journal-title":"Conf Proc IEEE Eng Med Biol Soc"},{"key":"2026011721233145000_ejhf1113-bib-0032","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1016\/j.healun.2013.07.013","article-title":"Diagnosis of hemolysis and device thrombosis with lactate dehydrogenase during left ventricular assist device support","volume":"33","author":"Shah","year":"2014","journal-title":"J Heart Lung Transplant"},{"key":"2026011721233145000_ejhf1113-bib-0033","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1097\/MAT.0000000000000488","article-title":"Ventricular assist device implantation configurations impact overall mechanical circulatory support system thrombogenic potential","volume":"63","author":"Chiu","year":"2017","journal-title":"ASAIO J"},{"key":"2026011721233145000_ejhf1113-bib-0034","doi-asserted-by":"crossref","first-page":"889","DOI":"10.1016\/j.jacc.2013.11.018","article-title":"Late bleeding and neurological sequelae after HeartMate II left ventricular assist device: risk factors from the prequel","volume":"63","author":"Najjar","year":"2014","journal-title":"J Am Coll Cardiol"},{"key":"2026011721233145000_ejhf1113-bib-0035","doi-asserted-by":"crossref","first-page":"880","DOI":"10.1016\/j.jacc.2013.08.1656","article-title":"Pre-operative risk factors of bleeding and stroke during left ventricular assist device support: an analysis of more than 900 HeartMate II outpatients","volume":"63","author":"Boyle","year":"2014","journal-title":"J Am Coll Cardiol"},{"key":"2026011721233145000_ejhf1113-bib-0036","doi-asserted-by":"crossref","first-page":"1542","DOI":"10.1016\/j.healun.2015.06.018","article-title":"Safety of reduced anti-thrombotic strategies in HeartMate II patients: a one-year analysis of the US-TRACE Study","volume":"34","author":"Katz","year":"2015","journal-title":"J Heart Lung Transplant"},{"key":"2026011721233145000_ejhf1113-bib-0037","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.healun.2013.10.005","article-title":"Device thrombosis in HeartMate II continuous-flow left ventricular assist devices: a multifactorial phenomenon","volume":"33","author":"Uriel","year":"2014","journal-title":"J Heart Lung Transplant"},{"key":"2026011721233145000_ejhf1113-bib-0038","doi-asserted-by":"crossref","first-page":"939","DOI":"10.1111\/aor.12471","article-title":"Incidence and risk factor analysis for gastrointestinal bleeding and pump thrombosis in left ventricular assist device recipients","volume":"39","author":"Lopilato","year":"2015","journal-title":"Artif Organs"},{"key":"2026011721233145000_ejhf1113-bib-0039","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/j.athoracsur.2008.10.027","article-title":"Platelet dysfunction in outpatients with left ventricular assist devices","volume":"87","author":"Steinlechner","year":"2009","journal-title":"Ann Thorac Surg"},{"key":"2026011721233145000_ejhf1113-bib-0040","doi-asserted-by":"crossref","first-page":"2003","DOI":"10.1161\/CIRCULATIONAHA.117.028303","article-title":"Hemocompatibility-related outcomes in the MOMENTUM 3 trial at 6 months: a randomized controlled study of a fully magnetically levitated pump in advanced heart failure","volume":"135","author":"Uriel","year":"2017","journal-title":"Circulation"},{"key":"2026011721233145000_ejhf1113-bib-0041","doi-asserted-by":"crossref","first-page":"946","DOI":"10.1111\/jth.12948","article-title":"Antithrombotic therapy for left ventricular assist devices in adults: a systematic review","volume":"13","author":"Baumann Kreuziger","year":"2015","journal-title":"J Thromb Haemost"},{"key":"2026011721233145000_ejhf1113-bib-0042","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCHEARTFAILURE.115.002296","article-title":"Antiplatelet therapy and adverse hematologic events during Heart Mate II support","volume":"9","author":"Saeed","year":"2016","journal-title":"Circ Heart Fail"},{"key":"2026011721233145000_ejhf1113-bib-0043","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1016\/j.thromres.2016.01.026","article-title":"Aspirin has limited ability to modulate shear-mediated platelet activation associated with elevated shear stress of ventricular assist devices","volume":"140","author":"Valerio","year":"2016","journal-title":"Thromb Res"},{"key":"2026011721233145000_ejhf1113-bib-0044","doi-asserted-by":"crossref","first-page":"1262","DOI":"10.1016\/j.athoracsur.2016.07.072","article-title":"Outcomes in HeartMate II patients with no antiplatelet therapy: 2-year results from the European TRACE study","volume":"103","author":"Netuka","year":"2017","journal-title":"Ann Thorac Surg"},{"key":"2026011721233145000_ejhf1113-bib-0045","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1161\/01.RES.41.1.2","article-title":"Flow-induced trauma to blood cells","volume":"41","author":"Sutera","year":"1977","journal-title":"Circ Res"},{"key":"2026011721233145000_ejhf1113-bib-0046","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1007\/s10544-015-0015-1","article-title":"Microfluidic emulation of mechanical circulatory support device shear-mediated platelet activation","volume":"17","author":"Dimasi","year":"2015","journal-title":"Biomed Microdevices"},{"key":"2026011721233145000_ejhf1113-bib-0047","doi-asserted-by":"crossref","first-page":"184","DOI":"10.5301\/ijao.5000485","article-title":"Microfluidic approaches for the assessment of blood cell trauma: a focus on thrombotic risk in mechanical circulatory support devices","volume":"39","author":"Consolo","year":"2016","journal-title":"Int J Artif Organs"}],"container-title":["European Journal of Heart Failure"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fejhf.1113","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/academic.oup.com\/eurjhf\/article-pdf\/20\/4\/792\/66269992\/eurjhf_20_4_792.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/eurjhf\/article-pdf\/20\/4\/792\/66269992\/eurjhf_20_4_792.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,18]],"date-time":"2026-01-18T02:26:05Z","timestamp":1768703165000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/eurjhf\/article\/20\/4\/792\/8414824"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,12,28]]},"references-count":47,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2017,12,28]]},"published-print":{"date-parts":[[2018,4,1]]}},"URL":"https:\/\/doi.org\/10.1002\/ejhf.1113","relation":{},"ISSN":["1388-9842","1879-0844"],"issn-type":[{"value":"1388-9842","type":"print"},{"value":"1879-0844","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2018,4]]},"published":{"date-parts":[[2017,12,28]]}}}