{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T07:38:25Z","timestamp":1792654705966,"version":"4.5.0"},"reference-count":24,"publisher":"Wiley","issue":"8","license":[{"start":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T00:00:00Z","timestamp":1785369600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T00:00:00Z","timestamp":1785369600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"funder":[{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["23K24750"],"award-info":[{"award-number":["23K24750"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100012002","name":"Descente and Ishimoto Memorial Foundation for the Promotion of Sports Science","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100012002","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["European Journal of Sport Science"],"published-print":{"date-parts":[[2026,8]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:p>\n                    This study evaluated the validity and sensitivity of an extended field\u2010of\u2010view (EFOV) wireless palm\u2010sized ultrasound device for assessing quadriceps femoris cross\u2010sectional area (CSA), using magnetic resonance imaging (MRI) as the reference. Although previous studies have examined EFOV ultrasound, data validating EFOV wireless palm\u2010sized devices against MRI using large cohorts and training interventions have not been reported. In Experiment 1, midthigh CSA was measured in 100 young adults (75 males, 25 females) using ultrasound and MRI. Intra\u2010rater reliability was assessed via intraclass correlation coefficients (ICC), standard error of measurement (SEM), coefficient of variation (CV), and smallest detectable change (SDC). In Experiment 2, 11 males underwent an 8\u2010week resistance training program. Pre\u2010to\u2010post changes in CSA (\u0394CSA) were compared between the two imaging modalities. In Experiment 1, the device demonstrated excellent reliability for males (ICC\u00a0=\u00a00.996; SEM\u00a0=\u00a00.85\u00a0cm\n                    <jats:sup>2<\/jats:sup>\n                    ; CV\u00a0=\u00a01.19%; SDC\u00a0=\u00a02.35\u00a0cm\n                    <jats:sup>2<\/jats:sup>\n                    ) and females (ICC\u00a0=\u00a00.993; SEM\u00a0=\u00a00.95\u00a0cm\n                    <jats:sup>2<\/jats:sup>\n                    ; CV\u00a0=\u00a01.73%; SDC\u00a0=\u00a02.63\u00a0cm\n                    <jats:sup>2<\/jats:sup>\n                    ). A strong correlation (\n                    <jats:italic>r<\/jats:italic>\n                    \u00a0=\u00a00.98,\n                    <jats:italic>p<\/jats:italic>\n                    \u00a0&lt;\u00a00.001) was observed between ultrasound and MRI, with a mean bias of \u22121.23\u00a0\u00b1\u00a02.70\u00a0cm\n                    <jats:sup>2<\/jats:sup>\n                    . In Experiment 2, both modalities detected significant hypertrophy (\n                    <jats:italic>p<\/jats:italic>\n                    \u00a0&lt;\u00a00.001). The mean \u0394CSA measured by ultrasound (3.77\u00a0cm\n                    <jats:sup>2<\/jats:sup>\n                    , 5.98%) exceeded the SDC (2.35\u00a0cm\n                    <jats:sup>2<\/jats:sup>\n                    ). \u0394CSA correlated strongly between modalities (\n                    <jats:italic>r<\/jats:italic>\n                    \u00a0=\u00a00.92,\n                    <jats:italic>p<\/jats:italic>\n                    \u00a0&lt;\u00a00.001). The EFOV wireless palm\u2010sized ultrasound device is a valid and sensitive tool for quantifying quadriceps femoris CSA and monitoring muscle adaptations, suitable for athletic performance and clinical settings.\n                  <\/jats:p>","DOI":"10.1002\/ejsc.70234","type":"journal-article","created":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T03:41:21Z","timestamp":1785469281000},"source":"Crossref","is-referenced-by-count":0,"title":["Validity and Sensitivity of Extended Field\u2010of\u2010View Wireless Palm\u2010Sized Ultrasonography for Assessing Muscle Hypertrophy"],"prefix":"10.1002","volume":"26","author":[{"given":"Tatsuki","family":"Fukumitsu","sequence":"first","affiliation":[{"name":"Graduate School of Informatics and Engineering The University of Electro\u2010Communications  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2705-1601","authenticated-orcid":false,"given":"Yuto","family":"Hashimoto","sequence":"additional","affiliation":[{"name":"Faculty of Sport Science Nippon Sports\u00a0Science University  Tokyo Japan"},{"name":"Meiji Yasuda Health Promotion Center Meiji Yasuda Health Development Foundation  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sari","family":"Kanbayashi","sequence":"additional","affiliation":[{"name":"Graduate School of Informatics and Engineering The University of Electro\u2010Communications  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Madoka","family":"Ogawa","sequence":"additional","affiliation":[{"name":"Institute\u00a0for Liberal Arts Institute of Science Tokyo  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mizuki","family":"Sudo","sequence":"additional","affiliation":[{"name":"Physical Fitness Research Institute Meiji Yasuda Life Foundation of Health and\u00a0Welfare  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1978-2455","authenticated-orcid":false,"given":"Takanobu","family":"Okamoto","sequence":"additional","affiliation":[{"name":"Faculty of Sport Science Nippon Sports\u00a0Science University  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0896-7008","authenticated-orcid":false,"given":"Soichi","family":"Ando","sequence":"additional","affiliation":[{"name":"Graduate School of Informatics and Engineering The University of Electro\u2010Communications  Tokyo Japan"},{"name":"Physical Fitness Research Institute Meiji Yasuda Life Foundation of Health and\u00a0Welfare  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,7,30]]},"reference":[{"key":"e_1_2_13_2_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00421\u2010009\u20101211\u20106"},{"key":"e_1_2_13_3_1","volume-title":"Acsm's Guidelines for Exercise Testing and Prescription","author":"American College of Sports Medicine","year":"2021"},{"key":"e_1_2_13_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1748\u20101716.1993.tb09573.x"},{"key":"e_1_2_13_5_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41598\u2010020\u201071123\u20106"},{"key":"e_1_2_13_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ultrasmedbio.2018.07.010"},{"key":"e_1_2_13_7_1","doi-asserted-by":"publisher","DOI":"10.1152\/physrev.00017.2022"},{"key":"e_1_2_13_8_1","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.2000.89.1.104"},{"key":"e_1_2_13_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.physbeh.2022.113737"},{"key":"e_1_2_13_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcm.2016.02.012"},{"key":"e_1_2_13_11_1","doi-asserted-by":"publisher","DOI":"10.1002\/ejsc.70145"},{"key":"e_1_2_13_12_1","doi-asserted-by":"publisher","DOI":"10.1519\/JSC.0000000000000532"},{"key":"e_1_2_13_13_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0311043"},{"key":"e_1_2_13_14_1","doi-asserted-by":"publisher","DOI":"10.1123\/ijspp.2021\u20100451"},{"key":"e_1_2_13_15_1","doi-asserted-by":"publisher","DOI":"10.1519\/JSC.0000000000004196"},{"key":"e_1_2_13_16_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0276154"},{"key":"e_1_2_13_17_1","doi-asserted-by":"publisher","DOI":"10.1002\/jcsm.12210"},{"key":"e_1_2_13_18_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00421\u2010010\u20101402\u20101"},{"key":"e_1_2_13_19_1","doi-asserted-by":"publisher","DOI":"10.1113\/EP090655"},{"key":"e_1_2_13_20_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0207847"},{"key":"e_1_2_13_21_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00421\u2010003\u20100961\u20109"},{"key":"e_1_2_13_22_1","doi-asserted-by":"publisher","DOI":"10.1002\/jcsm.12172"},{"key":"e_1_2_13_23_1","doi-asserted-by":"publisher","DOI":"10.14814\/phy2.14683"},{"key":"e_1_2_13_24_1","doi-asserted-by":"publisher","DOI":"10.1152\/japplphysiol.00170.2020"},{"key":"e_1_2_13_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ultrasmedbio.2023.02.018"}],"container-title":["European Journal of Sport Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ejsc.70234","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/ejsc.70234","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ejsc.70234","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T06:50:28Z","timestamp":1792651828000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ejsc.70234"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,30]]},"references-count":24,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2026,8]]}},"alternative-id":["10.1002\/ejsc.70234"],"URL":"https:\/\/doi.org\/10.1002\/ejsc.70234","archive":["Portico"],"relation":{},"ISSN":["1746-1391","1536-7290"],"issn-type":[{"value":"1746-1391","type":"print"},{"value":"1536-7290","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,30]]},"article-number":"e70234"}}