{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T23:20:32Z","timestamp":1785540032537,"version":"3.56.0"},"reference-count":36,"publisher":"Oxford University Press (OUP)","issue":"11","license":[{"start":{"date-parts":[[2011,11,1]],"date-time":"2011-11-01T00:00:00Z","timestamp":1320105600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"},{"start":{"date-parts":[[2011,9,20]],"date-time":"2011-09-20T00:00:00Z","timestamp":1316476800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["setac.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2011,11,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>We have used a novel gas chromatography\/mass spectrometry (GC\/MS)-based approach to quantify perchloroethylene (PCE) residues in dry-cleaned fabrics. Residual PCE was extracted from fabric samples with methanol and concentration was calculated by the gas chromatographic peak area, standardized using PCE calibration data. Extracts examined were from samples of 100% wool, polyester, cotton, or silk, which were dry cleaned from one to six times in seven different Northern Virginia dry-cleaning establishments. Additional experiments were conducted to investigate the kinetics of PCE release in the extraction solvent and to the open air. We found that polyester, cotton, and wool retained \u2265\u2009\u00b5M levels of PCE, that these levels increased in successive dry-cleaning cycles, and that PCE is slowly volatilized from these fabrics under ambient room air conditions. We found that silk does not retain appreciable PCE. Measured differences across dry-cleaning establishments and fabric type suggest more vigorous monitoring of PCE residues may be warranted. Environ. Toxicol. Chem. 2011;30:2481\u20132487. \u00a9 2011 SETAC<\/jats:p>","DOI":"10.1002\/etc.665","type":"journal-article","created":{"date-parts":[[2011,8,31]],"date-time":"2011-08-31T23:50:09Z","timestamp":1314834609000},"page":"2481-2487","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":25,"title":["Quantification of perchloroethylene residues in dry-cleaned fabrics"],"prefix":"10.1093","volume":"30","author":[{"given":"Katy S","family":"Sherlach","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander P","family":"Gorka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexa","family":"Dantzler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul D","family":"Roepe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2011,11,1]]},"reference":[{"key":"2026020510281708000_bib1","author":"U.S. Environmental Protection Agency","year":"1994"},{"key":"2026020510281708000_bib2","author":"Halogenated Solvents Industry Alliance","year":"2010"},{"key":"2026020510281708000_bib3","author":"European Chlorinated Solvents Association","year":"2007"},{"key":"2026020510281708000_bib4","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1080\/00039896.1994.9955005","article-title":"Occupational and environmental exposure to perchloroethylene (PCE) in dry cleaners and their family members","volume":"49","author":"Aggazzotti","year":"1994","journal-title":"Arch Environ Health"},{"key":"2026020510281708000_bib5","author":"National Research Council","year":"2010"},{"key":"2026020510281708000_bib6","author":"U.S. Agency for Toxic Substances and Disease Registry","year":"1997"},{"key":"2026020510281708000_bib7","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1007\/s004200050421","article-title":"Monitoring of occupational exposure to tetrachloroethyene in blood and urine in comparison with urinalysis for trichloroacetic acid","volume":"73","author":"Furuki","year":"2000","journal-title":"Int Arch Occup Environ Health"},{"key":"2026020510281708000_bib8","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1016\/j.coem.2004.03.005","article-title":"Chlorinated hydrocarbon solvents","volume":"4","author":"Armstrong","year":"2004","journal-title":"Clin Occup Environ Med"},{"key":"2026020510281708000_bib9","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/S0378-4274(00)00281-2","article-title":"Neoantigen formation and clastogenic action of HCFC-123 and perchloroethylene in human MCL-5cells","volume":"124","author":"White","year":"2001","journal-title":"Toxicol Lett"},{"key":"2026020510281708000_bib10","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1007\/s10549-004-8268-z","article-title":"An ecological study of the association of environmental chemicals on breast cancer incidence Texas","volume":"92","author":"Coyle","year":"2005","journal-title":"Breast Cancer Res Treat"},{"key":"2026020510281708000_bib11","first-page":"159","volume-title":"Dry Cleaning, Some Chlorinated Solvents, and Other Industrial Chemicals","author":"International Agency for Research on Cancer","year":"1995"},{"key":"2026020510281708000_bib12","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1080\/10473289.1999.10463787","article-title":"Residual perchloroethylene in dry-cleaned acetate: the effect of pressing and the extent of inter-dry cleaner variability","volume":"49","author":"Brand","year":"1999","journal-title":"J Air Waste Manag Assoc"},{"key":"2026020510281708000_bib13","doi-asserted-by":"crossref","first-page":"296","DOI":"10.1016\/S0013-9351(89)80042-8","article-title":"Residual tetrachloroethylene in dry-cleaned clothes","volume":"48","author":"Kawauchi","year":"1989","journal-title":"Environ Res"},{"key":"2026020510281708000_bib14","first-page":"573","article-title":"Method for determining chlorinated solvent residues in dry cleaning fabrics with gas chromatography-mass spectrometry (in Chinese)","volume":"20","author":"Chen","year":"2002","journal-title":"Se Pu"},{"key":"2026020510281708000_bib15","author":"State Coalition for Remediation of Drycleaners","year":"2002"},{"key":"2026020510281708000_bib16","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1016\/S0360-1323(98)00014-6","article-title":"Indoor perchloroethylene accumulation from dry cleaned clothing on residential premises","volume":"34","author":"Chao","year":"1998","journal-title":"Build Environ"},{"key":"2026020510281708000_bib17","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/S0013-9351(05)80155-0","article-title":"The temperature dependence of the emission of perchloroethylene from dry cleaned fabrics","volume":"52","author":"Guo","year":"1990","journal-title":"Environ Res"},{"key":"2026020510281708000_bib18","first-page":"475","article-title":"Effect of dry-cleaned clothes on tetrachloroethylene levels in indoor air, personal air, and breath for residents of several New Jersey homes","volume":"1","author":"Thomas","year":"1991","journal-title":"J Expo Anal Environ Epidemiol"},{"key":"2026020510281708000_bib19","doi-asserted-by":"crossref","first-page":"1219","DOI":"10.1016\/0960-1686(90)90087-4","article-title":"Emissions of perchloroethylene from dry cleaned fabrics","volume":"24","author":"Tichenor","year":"1990","journal-title":"Atmospher Environ"},{"key":"2026020510281708000_bib20","author":"Wallace","year":"1996"},{"key":"2026020510281708000_bib21","author":"U.S. Environmental Protection Agency","year":"2001"},{"key":"2026020510281708000_bib22","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1016\/S0013-9351(05)80132-X","article-title":"Tetrachloroethene air pollution originating from coin-operated dry cleaning establishments","volume":"53","author":"Gulyas","year":"1990","journal-title":"Environ Res"},{"key":"2026020510281708000_bib23","first-page":"65","article-title":"Measurement of air exchange rate of stationary vehicles and estimation of in-vehicle exposure","volume":"8","author":"Park","year":"1998","journal-title":"J Expo Anal Environ Epidemiol"},{"key":"2026020510281708000_bib24","doi-asserted-by":"crossref","first-page":"566","DOI":"10.1080\/15298669091370112","article-title":"Perchloroethylene exposure assessment among dry cleaning workers","volume":"51","author":"Solet","year":"1990","journal-title":"Am Ind Hyg Assoc J"},{"key":"2026020510281708000_bib25","doi-asserted-by":"crossref","first-page":"1200","DOI":"10.1021\/bm061017y","article-title":"Chemical and physical properties of sulfonated silk fabrics","volume":"8","author":"Taddei","year":"2007","journal-title":"Biomacromolecules"},{"key":"2026020510281708000_bib26","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1042\/bj0590062","article-title":"The amino acid composition of wool","volume":"59","author":"Corfield","year":"1955","journal-title":"Biochem J"},{"key":"2026020510281708000_bib27","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1289\/ehp.02110655","article-title":"Apartment residents' and day care workers' exposures to tetrachloroethylene and deficits in visual contrast sensitivity","volume":"110","author":"Schreiber","year":"2002","journal-title":"Environ Health Perspect"},{"key":"2026020510281708000_bib28","author":"U.S. Agency for Toxic Substances and Disease Registry","year":"1997"},{"key":"2026020510281708000_bib29","author":"U.S. Agency for Toxic Substances and Disease Registry","year":"1997"},{"key":"2026020510281708000_bib30","author":"National Toxicology Program","year":"2004"},{"key":"2026020510281708000_bib31","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1093\/mutage\/9.5.429","article-title":"Dichloroacetic acid and related compounds: induction of prophage in E.coli and mutagenicity and mutation spectra in Salmonella TA100","volume":"9","author":"DeMarini","year":"1994","journal-title":"Mutagenesis"},{"key":"2026020510281708000_bib32","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1002\/em.20350","article-title":"Difficulty of mode of action determination for trichloroethylene: An example of complex interactions of metabolites and other chemical exposures","volume":"49","author":"Caldwell","year":"2008","journal-title":"Environ Mol Mutagen"},{"key":"2026020510281708000_bib33","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1093\/toxsci\/67.1.17","article-title":"PBPK modeling of the percutaneous absorption of perchloroethylene from a soil matrix in rats and humans","volume":"67","author":"Poet","year":"2002","journal-title":"Toxicol Sci"},{"key":"2026020510281708000_bib34","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1016\/j.yrtph.2006.02.009","article-title":"A review of perchloroethylene and rat mononuclear cell leukemia","volume":"45","author":"Ishmael","year":"2006","journal-title":"Regul Toxicol Pharm"},{"key":"2026020510281708000_bib35","author":"National Toxicology Program","year":"1986"},{"key":"2026020510281708000_bib36","volume-title":"Advances in the Prevention of Occupational Respiratory Diseases: Proceedings","author":"Nagano","year":"1998"}],"container-title":["Environmental Toxicology and Chemistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fetc.665","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/academic.oup.com\/etc\/article\/30\/11\/2481\/7765429","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/etc\/article\/30\/11\/2481\/7765429","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,5]],"date-time":"2026-02-05T15:28:26Z","timestamp":1770305306000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/etc\/article\/30\/11\/2481\/7765429"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,11,1]]},"references-count":36,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2011,11,1]]},"published-print":{"date-parts":[[2011,11,1]]}},"URL":"https:\/\/doi.org\/10.1002\/etc.665","relation":{},"ISSN":["0730-7268","1552-8618"],"issn-type":[{"value":"0730-7268","type":"print"},{"value":"1552-8618","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2011,11,1]]},"published":{"date-parts":[[2011,11,1]]},"assertion":[{"value":"2011-05-26","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2011-08-04","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2011-09-20","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}