{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T07:02:28Z","timestamp":1790838148605,"version":"4.1.0"},"reference-count":50,"publisher":"Wiley","license":[{"start":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T00:00:00Z","timestamp":1790726400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T00:00:00Z","timestamp":1790726400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["beva.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Equine Veterinary Journal"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Force plates (FP) are considered the gold standard for quantitative equine gait evaluation but are limited to experimental use. An instrumented hoof boot (IHB) with pressure sensors and an inertial measurement unit would allow clinicians to objectively assess kinetic parameters and gait symmetry.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>To validate the IHB by comparing kinetic parameters with obtained FP data.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Study Design<\/jats:title>\n                    <jats:p>In vivo experiments.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Twenty\u2010seven horses were measured with IHBs on FPs at walk and trot. Mean value kinetic parameters recorded were: (1) peak vertical force (PVF) [N\/kg]\/peak vertical pressure (PVP) [N\/kg]; (2) vertical impulse (AUC) [Nms\/kg]; (3) peak loading rate (PLR) [N\/ms]; (4) stance duration (StD) [ms] and (5) time of peak vertical force (TPVF) [%stance]\/time of peak vertical pressure (TPVP) [%stance]. Agreement and correlation were assessed using Bland\u2013Altman analysis and Kendall's correlation coefficient\n                      <jats:italic>\u03c4<\/jats:italic>\n                      . Significance level was set at\n                      <jats:italic>\u03b1<\/jats:italic>\n                      \u2009=\u20095%.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Bland\u2013Altman plots showed an overall moderate to good agreement with following mean difference (bias) and 95% limits of agreement (95%LoA) for IHB and FP: PVF\/PVP [N\/kg] walk: bias \u22120.197 (95%LoA: \u22120.786 to 0.392), trot: bias 0.0516 (95%LoA: \u22121.01 to 1.11), AUC [Nms\/kg] walk: bias \u221280 (95%LoA: \u2212420 to 260), trot: bias \u221244.4 (95%LoA: \u2212291 to 202), PLR [N\/ms] walk: bias 0.467 (95%LoA: \u22120.582 to 1.52), trot: bias 6.24 (95%LoA: \u22120.675 to 13.2), StD [ms] walk: bias 60.4 (95%LoA: \u22126.36 to 127), trot: bias 28.7 (95%LoA: \u22121.47 to 58.8), TPVF\/TPVP [%stance] walk: bias \u22121.72 (95%LoA: \u22128.28 to 4.83), trot: bias \u22122.8 (95%LoA: \u22126.43 to 0.832). Correlations were very strong to fair positive.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Main Limitations<\/jats:title>\n                    <jats:p>Small, mixed\u2010breed population, pending repeatability study, ex vivo calibration on manufacturers' behalf.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The IHB is a portable, quick method for kinetic gait analysis that approximates the gold standard FP, offering a promising tool for future clinical use.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/evj.70332","type":"journal-article","created":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T06:53:16Z","timestamp":1790837596000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Validation of a novel instrumented hoof boot with pressure sensors using force plate gait kinetics in horses at walk and trot"],"prefix":"10.1002","author":[{"ORCID":"https:\/\/orcid.org\/0009-0001-3129-6727","authenticated-orcid":false,"given":"Jasmin","family":"Keller","sequence":"first","affiliation":[{"name":"Clinic for Horses University of Veterinary Medicine Hannover  Hannover Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5977-388X","authenticated-orcid":false,"given":"Max J.","family":"Hassenstein","sequence":"additional","affiliation":[{"name":"Institute of Animal Genomics University of Veterinary Medicine Hannover  Hannover Germany"},{"name":"Unit for Research Data Management University of Veterinary Medicine Hannover  Hannover Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9955-748X","authenticated-orcid":false,"given":"Klaus","family":"Jung","sequence":"additional","affiliation":[{"name":"Institute of Animal Genomics University of Veterinary Medicine Hannover  Hannover Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3161-9055","authenticated-orcid":false,"given":"Florian","family":"Geburek","sequence":"additional","affiliation":[{"name":"Clinic for Horses University of Veterinary Medicine Hannover  Hannover Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,9,30]]},"reference":[{"issue":"6","key":"e_1_2_14_2_1","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1111\/j.2042-3306.1988.tb04655.x","article-title":"Evaluation of equine locomotion during different degrees of experimentally induced lameness I: lameness model and quantification of ground reaction force patterns of the limbs","volume":"20","author":"Merkens HW","year":"1988","journal-title":"Equine Vet J"},{"key":"e_1_2_14_3_1","first-page":"31","volume-title":"Equine locomotion","author":"Clayton HM","year":"2013"},{"issue":"1","key":"e_1_2_14_4_1","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/j.tvjl.2004.10.003","article-title":"The force plate: established technology, new applications","volume":"169","author":"Clayton HM","year":"2005","journal-title":"Vet J"},{"issue":"4","key":"e_1_2_14_5_1","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1111\/j.2042-3306.1991.tb03715.x","article-title":"Identification of subclinical tendon injury from ground reaction force analysis","volume":"23","author":"Dow SM","year":"1991","journal-title":"Equine Vet J"},{"issue":"5","key":"e_1_2_14_6_1","doi-asserted-by":"crossref","first-page":"549","DOI":"10.2460\/ajvr.1999.60.05.549","article-title":"Disease\u2010specific changes in equine ground reaction force data documented by use of principal component analysis","volume":"60","author":"Williams GE","year":"1999","journal-title":"Am J Vet Res"},{"issue":"3","key":"e_1_2_14_7_1","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1016\/j.jevs.2007.01.007","article-title":"Vertical frontlimb ground reaction forces of sound and lame warmbloods differ from those in quarter horses","volume":"27","author":"Back W","year":"2007","journal-title":"J Equine Vet Sci"},{"key":"e_1_2_14_8_1","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.tvjl.2018.01.006","article-title":"On the brink of daily clinical application of objective gait analysis: what evidence do we have so far from studies using an induced lameness model?","volume":"234","author":"Serra Bragan\u00e7a FM","year":"2018","journal-title":"Vet J"},{"issue":"3","key":"e_1_2_14_9_1","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1016\/j.tvjl.2008.12.012","article-title":"Use of a stand\u2010alone pressure plate for the objective evaluation of forelimb symmetry in sound ponies at walk and trot","volume":"183","author":"Oosterlinck M","year":"2010","journal-title":"Vet J"},{"issue":"3","key":"e_1_2_14_10_1","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1016\/j.tvjl.2009.08.024","article-title":"Comparison of pressure plate and force plate gait kinetics in sound warmbloods at walk and trot","volume":"186","author":"Oosterlinck M","year":"2010","journal-title":"Vet J"},{"issue":"2","key":"e_1_2_14_11_1","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1111\/j.2042-3306.1993.tb02923.x","article-title":"Ground reaction force patterns of Dutch warmblood horses at normal trot","volume":"25","author":"Merkens HW","year":"1993","journal-title":"Equine Vet J"},{"key":"e_1_2_14_12_1","first-page":"233","article-title":"A force and motion study of the foreleg of a standardbred trotter","volume":"2","author":"Quddus M","year":"1978","journal-title":"J Equine Med Surg"},{"issue":"3","key":"e_1_2_14_13_1","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1111\/j.2042-3306.1986.tb03600.x","article-title":"Ground reaction force patterns of Dutch warmblood horses at normal walk","volume":"18","author":"Merkens HW","year":"1986","journal-title":"Equine Vet J"},{"issue":"12","key":"e_1_2_14_14_1","doi-asserted-by":"crossref","first-page":"2279","DOI":"10.2460\/ajvr.1970.31.12.2279","article-title":"Impact force measurement using preloaded transducers","volume":"31","author":"Frederick F","year":"1970","journal-title":"Am J Vet Res"},{"issue":"1","key":"e_1_2_14_15_1","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1016\/S0737-0806(06)80079-1","article-title":"Measurement of vertical forces and temporal components of the strides of horses using instrumented shoes","volume":"10","author":"Ratzlaff MH","year":"1990","journal-title":"J Equine Vet Sci"},{"issue":"8","key":"e_1_2_14_16_1","doi-asserted-by":"crossref","first-page":"979","DOI":"10.2460\/ajvr.2000.61.979","article-title":"Use of an instrument sandwiched between the hoof and shoe to measure vertical ground reaction forces and three\u2010dimensional acceleration at the walk, trot, and canter in horses","volume":"61","author":"Kai M","year":"2000","journal-title":"Am J Vet Res"},{"issue":"2","key":"e_1_2_14_17_1","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1159\/000147431","article-title":"Concept of a force\u2010measuring horseshoe","volume":"146","author":"Roepstorff L","year":"1993","journal-title":"Cells Tissues Organs"},{"issue":"8","key":"e_1_2_14_18_1","doi-asserted-by":"crossref","first-page":"997","DOI":"10.1016\/0021-9290(94)90216-X","article-title":"Semi\u2010quantitative analysis of hoof\u2010strike in the horse","volume":"27","author":"Hjert\u00e9n G","year":"1994","journal-title":"J Biomech"},{"key":"e_1_2_14_19_1","first-page":"587","article-title":"A method to analyse forces and moments in the extremities of the horse during the stance phase at the trot","volume":"2","author":"Hjert\u00e9n G","year":"1987","journal-title":"Equine Exerc Physiol Suppl"},{"issue":"4","key":"e_1_2_14_20_1","first-page":"1","article-title":"Studies on the draught force of horses. Development of a method using strain gauges for measuring forces between hoof and ground","volume":"8","author":"Bj\u00f6rck G","year":"1958","journal-title":"Acta Agric Scand"},{"key":"e_1_2_14_21_1","doi-asserted-by":"crossref","first-page":"336","DOI":"10.1016\/j.jbiomech.2008.11.017","article-title":"Design and validation of a dynamometric horseshoe for the measurement of 3D ground reaction force on a moving horse","volume":"42","author":"Chateau H","year":"2009","journal-title":"J Biomech"},{"issue":"10","key":"e_1_2_14_22_1","doi-asserted-by":"crossref","first-page":"2102","DOI":"10.1016\/j.jbiomech.2004.08.024","article-title":"Design and demonstration of a dynamometric horseshoe for measuring ground reaction loads of horses during racing conditions","volume":"38","author":"Roland ES","year":"2005","journal-title":"J Biomech"},{"key":"e_1_2_14_23_1","volume-title":"Biokinetische Untersuchungen am Huf des Pferdes mittels eines Kraftmessschuhes [Biokinetic investigations of the equine hoof using a force\u2010measuring hoofboot] [dissertation]","author":"Dohne W","year":"1991"},{"issue":"9","key":"e_1_2_14_24_1","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1111\/j.2042-3306.1990.tb04731.x","article-title":"Investigation of the vertical hoof force distribution in the equine forelimb with an instrumented horseboot","volume":"22","author":"Barrey E","year":"1990","journal-title":"Equine Vet J"},{"key":"e_1_2_14_25_1","first-page":"1","volume-title":"2023 IEEE biomedical circuits and systems conference (BioCAS)","author":"Devolin A"},{"key":"e_1_2_14_26_1","volume-title":"La machine animale: locomotion terrestre et a\u00e9rienne","author":"Marey EJ","year":"1878"},{"issue":"4","key":"e_1_2_14_27_1","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/j.jevs.2007.02.006","article-title":"The accuracy and precision of an equine in\u2010shoe pressure measurement system as a tool for gait analysis","volume":"27","author":"Perino VV","year":"2007","journal-title":"J Equine Vet Sci"},{"issue":"1","key":"e_1_2_14_28_1","doi-asserted-by":"crossref","first-page":"23","DOI":"10.2460\/ajvr.2001.62.23","article-title":"Evaluation of an in\u2010shoe pressure measurement system in horses","volume":"62","author":"Judy CE","year":"2001","journal-title":"Am J Vet Res"},{"issue":"18","key":"e_1_2_14_29_1","doi-asserted-by":"crossref","first-page":"2485","DOI":"10.3390\/ani12182485","article-title":"Bilateral change in vertical hoof force distribution in horses with unilateral forelimb lameness before and after successful diagnostic anaesthesia","volume":"12","author":"Hoffmann JR","year":"2022","journal-title":"Animals"},{"issue":"12","key":"e_1_2_14_30_1","first-page":"614","article-title":"Biostatistics 104: correlational analysis","volume":"44","author":"Chan YH","year":"2003","journal-title":"Singapore Med J"},{"key":"e_1_2_14_31_1","doi-asserted-by":"crossref","first-page":"530","DOI":"10.1111\/j.2042-3306.2010.00190.x","article-title":"Velocity\u2010dependent changes of time, force and spatial parameters in warmblood horses walking and trotting on a treadmill","volume":"38","author":"Weishaupt MA","year":"2010","journal-title":"Equine Vet J Suppl"},{"issue":"3","key":"e_1_2_14_32_1","doi-asserted-by":"crossref","first-page":"600","DOI":"10.1111\/evj.13344","article-title":"Adaptation strategies of horses with induced forelimb lameness walking on a treadmill","volume":"53","author":"Braganca F","year":"2020","journal-title":"Equine Vet J"},{"issue":"1","key":"e_1_2_14_33_1","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1016\/j.tvjl.2010.08.016","article-title":"A pressure plate study on fore and hindlimb loading and the association with hoof contact area in sound ponies at the walk and trot","volume":"190","author":"Oosterlinck M","year":"2011","journal-title":"Vet J"},{"issue":"4","key":"e_1_2_14_34_1","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1106\/8BFB-GC8P-XQ47-YCQ0","article-title":"Fundamental understanding of piezoelectric strain sensors","volume":"11","author":"Sirohi J","year":"2000","journal-title":"J Intell Mater Syst Struct"},{"key":"e_1_2_14_35_1","volume-title":"Modellbildung der Messunsicherheit resistiver Sensorsysteme [Modeling the Measurement Uncertainty of Resistive Sensor Systems] [dissertation]","author":"Lotichius J","year":"2017"},{"issue":"12","key":"e_1_2_14_36_1","doi-asserted-by":"crossref","first-page":"1597","DOI":"10.1088\/0960-1317\/14\/12\/001","article-title":"Design optimization of a piezoresistive pressure sensor considering the output signal\u2010to\u2010noise ratio","volume":"14","author":"Bae B","year":"2004","journal-title":"J Micromech Microeng"},{"issue":"10","key":"e_1_2_14_37_1","doi-asserted-by":"crossref","first-page":"1805","DOI":"10.2460\/ajvr.2005.66.1805","article-title":"Association between subjective lameness grade and kinetic gait parameters in horses with experimentally induced forelimb lameness","volume":"66","author":"Ishihara A","year":"2005","journal-title":"Am J Vet Res"},{"key":"e_1_2_14_38_1","doi-asserted-by":"crossref","DOI":"10.1016\/j.jevs.2021.103862","article-title":"Evaluation of within\u2010 and between\u2010session reliability of the TekscanTM hoof system with a glue\u2010on shoe","volume":"110","author":"Logan AA","year":"2022","journal-title":"J Equine Vet Sci"},{"key":"e_1_2_14_39_1","doi-asserted-by":"crossref","DOI":"10.1016\/j.jevs.2020.103314","article-title":"Riding soundness\u2014comparison of subjective with objective lameness assessments of owner\u2010sound horses at trot on a treadmill","volume":"95","author":"M\u00fcller\u2010Quirin J","year":"2020","journal-title":"J Equine Vet Sci"},{"issue":"33","key":"e_1_2_14_40_1","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1111\/j.2042-3306.2001.tb05376.x","article-title":"Assessment of gait irregularities in the horse: eye vs. gait analysis","volume":"33","author":"Weishaupt MA","year":"2001","journal-title":"Equine Vet J"},{"issue":"48","key":"e_1_2_14_41_1","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1111\/evj.12486_22","article-title":"Head and pelvic movement asymmetries at trot in riding horses perceived as sound by their owner","volume":"47","author":"Rhodin M","year":"2015","journal-title":"Equine Vet J"},{"issue":"8","key":"e_1_2_14_42_1","doi-asserted-by":"crossref","first-page":"727","DOI":"10.2746\/0425164044848244","article-title":"Compensatory load redistribution of horses with induced weightbearing hindlimb lameness trotting on a treadmill","volume":"36","author":"Weishaupt MA","year":"2004","journal-title":"Equine Vet J"},{"issue":"1","key":"e_1_2_14_43_1","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1016\/j.tvjl.2004.09.004","article-title":"Compensatory load redistribution of horses with induced weight\u2010bearing forelimb lameness trotting on a treadmill","volume":"171","author":"Weishaupt MA","year":"2006","journal-title":"Vet J"},{"key":"e_1_2_14_44_1","doi-asserted-by":"crossref","DOI":"10.1016\/j.jevs.2020.103208","article-title":"Correlational characteristics of hoof conformation and midstance kinetics at walk","volume":"94","author":"Faramarzi B","year":"2020","journal-title":"J Equine Vet Sci"},{"issue":"4","key":"e_1_2_14_45_1","doi-asserted-by":"crossref","DOI":"10.1002\/vetr.450","article-title":"Influence of trimming, hoof angle and shoeing on breakover duration in sound horses examined with hoof\u2010mounted inertial sensors","volume":"189","author":"Hagen J","year":"2021","journal-title":"Vet Rec"},{"key":"e_1_2_14_46_1","doi-asserted-by":"crossref","DOI":"10.1016\/j.tvjl.2020.105593","article-title":"Dynamic evaluation of toe\u2013heel and medio\u2010lateral load distribution and hoof landing patterns in sound, unshod standardbred horses with toed\u2010in, toed\u2010out and normal hoof conformation","volume":"268","author":"Mokry A","year":"2021","journal-title":"Vet J"},{"issue":"5","key":"e_1_2_14_47_1","doi-asserted-by":"crossref","first-page":"527","DOI":"10.2460\/ajvr.77.5.527","article-title":"Effect of hoof boots and toe\u2010extension shoes on the forelimb kinetics of horses during walking","volume":"77","author":"Amitrano FN","year":"2016","journal-title":"Am J Vet Res"},{"issue":"38","key":"e_1_2_14_48_1","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1111\/j.2042-3306.2010.00231.x","article-title":"Influence of shoes with different weights on the motion of the limbs in Icelandic horses during toelt at different speeds","volume":"42","author":"Rumpler B","year":"2010","journal-title":"Equine Vet J"},{"issue":"3","key":"e_1_2_14_49_1","doi-asserted-by":"crossref","first-page":"390","DOI":"10.3390\/ani13030390","article-title":"Is markerless more or less? Comparing a smartphone computer vision method for equine lameness assessment to multi\u2010camera motion capture","volume":"13","author":"Lawin FJ","year":"2023","journal-title":"Animals"},{"issue":"1","key":"e_1_2_14_50_1","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1111\/evj.14089","article-title":"Objective movement asymmetry in horses is comparable between markerless technology and sensor\u2010based systems","volume":"57","author":"Kallerud AS","year":"2025","journal-title":"Equine Vet J"},{"issue":"7","key":"e_1_2_14_51_1","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0254813","article-title":"Automatic methods of hoof\u2010on and \u2010off detection in horses using wearable inertial sensors during walk and trot on asphalt, sand and grass","volume":"16","author":"Briggs EV","year":"2021","journal-title":"PLoS One"}],"container-title":["Equine Veterinary Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/beva.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/evj.70332","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/beva.onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/evj.70332","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/beva.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/evj.70332","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T06:53:22Z","timestamp":1790837602000},"score":1,"resource":{"primary":{"URL":"https:\/\/beva.onlinelibrary.wiley.com\/doi\/10.1002\/evj.70332"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,30]]},"references-count":50,"alternative-id":["10.1002\/evj.70332"],"URL":"https:\/\/doi.org\/10.1002\/evj.70332","archive":["Portico"],"relation":{},"ISSN":["0425-1644","2042-3306"],"issn-type":[{"value":"0425-1644","type":"print"},{"value":"2042-3306","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,30]]},"assertion":[{"value":"2025-08-28","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-08-16","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-09-30","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"evj.70332"}}