{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T02:45:38Z","timestamp":1773542738325,"version":"3.50.1"},"reference-count":17,"publisher":"Wiley","issue":"11","license":[{"start":{"date-parts":[[2008,7,18]],"date-time":"2008-07-18T00:00:00Z","timestamp":1216339200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Head &amp; Neck"],"published-print":{"date-parts":[[2008,11]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background.<\/jats:title><jats:p>In a previous study at our institution, it was determined that resorbable screws with untapped drill holes resulted in the highest resistance forces to linear load when compared with titanium screws. The 1.1\u2010mm drill diameter\/2.0\u2010mm screw diameter and 1.5\/2.0 drill\/screw combinations were superior to the 1.1\/1.5 combinations; however, there was no conclusion as to the best screw size to drill bit diameter. The aim of this prospective study was to compare the pullout strength of resorbable screws in fresh frozen cadaveric laryngeal cartilage. The importance of drill hole diameter will also be determined.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods.<\/jats:title><jats:p>After debridement of connective tissue and perichondrium, 12 cartilage specimens were tested. Linear pullout strength of screws was measured using a load cell. Resorbable screws of size 2.0 mm were tested using drill hole diameters of 0.0 mm, 0.8 mm, and 1.5 mm. All tested screws were 6 mm in length or greater.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results.<\/jats:title><jats:p>We found no strong evidence that the means for the 0.8\/2.0 and 1.5\/2.0 differ or that the 0.0\/2.0 and 0.8\/2.0 means differ. There is evidence that the 0.0\/2.0 and 1.5\/2.0 means differ (adjusted <jats:italic>p<\/jats:italic> value .0108), with the 0.0\/2.0 combination having a smaller mean.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions.<\/jats:title><jats:p>Resorbable screws without predrilled holes result in less resistance to linear loads than either the resorbable screws with the 0.8\/2.0 or the 1.5\/2.0 drill\/screw combinations. The 1.5\/2.0 drill\/screw combination had the strongest pullout force, though this was not statistically significant. \u00a9 2008 Wiley Periodicals, Inc. Head Neck, 2008<\/jats:p><\/jats:sec>","DOI":"10.1002\/hed.20890","type":"journal-article","created":{"date-parts":[[2008,7,18]],"date-time":"2008-07-18T15:50:59Z","timestamp":1216396259000},"page":"1464-1468","source":"Crossref","is-referenced-by-count":2,"title":["Comparison of pullout strength of resorbable screws in human cadaveric laryngeal cartilage using different drill diameters"],"prefix":"10.1002","volume":"30","author":[{"given":"Andrea F.","family":"Lewis","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J. Randall","family":"Jordan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Doug E.","family":"Parsell","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mark","family":"Kosko","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2008,7,18]]},"reference":[{"key":"e_1_2_7_2_2","doi-asserted-by":"publisher","DOI":"10.1001\/archotol.125.8.877"},{"key":"e_1_2_7_3_2","doi-asserted-by":"publisher","DOI":"10.1177\/000348948209100416"},{"key":"e_1_2_7_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0196-0709(98)90081-3"},{"key":"e_1_2_7_5_2","doi-asserted-by":"publisher","DOI":"10.1097\/00005537-199901000-00023"},{"key":"e_1_2_7_6_2","doi-asserted-by":"publisher","DOI":"10.1097\/00005537-200012000-00032"},{"key":"e_1_2_7_7_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-0347(199812)20:8<707::AID-HED8>3.0.CO;2-Y"},{"key":"e_1_2_7_8_2","doi-asserted-by":"publisher","DOI":"10.1097\/00005537-200205000-00021"},{"key":"e_1_2_7_9_2","doi-asserted-by":"publisher","DOI":"10.1177\/000348940311200901"},{"key":"e_1_2_7_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/0142-9612(96)81421-9"},{"key":"e_1_2_7_11_2","doi-asserted-by":"publisher","DOI":"10.1097\/00001665-199405000-00012"},{"key":"e_1_2_7_12_2","doi-asserted-by":"publisher","DOI":"10.1001\/archotol.127.5.570"},{"key":"e_1_2_7_13_2","doi-asserted-by":"publisher","DOI":"10.1097\/MLG.0b013e31813437c6"},{"key":"e_1_2_7_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0196-0709(98)90080-1"},{"key":"e_1_2_7_15_2","first-page":"196","article-title":"Ossification of laryngeal cartilages on lateral cephalometric radiographs","volume":"75","author":"Mupparapu M","journal-title":"Angle Orthod"},{"key":"e_1_2_7_16_2","doi-asserted-by":"publisher","DOI":"10.1177\/019459989310900309"},{"key":"e_1_2_7_17_2","doi-asserted-by":"publisher","DOI":"10.1097\/00005131-199004020-00012"},{"key":"e_1_2_7_18_2","doi-asserted-by":"publisher","DOI":"10.1115\/1.2796022"}],"container-title":["Head &amp; Neck"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fhed.20890","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/hed.20890","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,13]],"date-time":"2023-10-13T23:08:33Z","timestamp":1697238513000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/hed.20890"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,7,18]]},"references-count":17,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2008,11]]}},"alternative-id":["10.1002\/hed.20890"],"URL":"https:\/\/doi.org\/10.1002\/hed.20890","archive":["Portico"],"relation":{},"ISSN":["1043-3074","1097-0347"],"issn-type":[{"value":"1043-3074","type":"print"},{"value":"1097-0347","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,7,18]]}}}