{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,11,21]],"date-time":"2023-11-21T14:23:40Z","timestamp":1700576620028},"reference-count":21,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2004,8,30]],"date-time":"2004-08-30T00:00:00Z","timestamp":1093824000000},"content-version":"vor","delay-in-days":3560,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J of Applied Biomaterials"],"published-print":{"date-parts":[[1994,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Bone\u2013implant displacements can be caused by rigid body motion and by differences in material properties of the implant and bone. In the present study of the tibial component in total knee replacement, we tested a series of tibial component fixation designs to determine how certain design features influenced the magnitude of the tangential displacement between the component and supporting bone in a canine model. The transverse expansion of the proximal tibia under static axial loading was measured in the intact tibia and then in the same bone following implantation of tibial components with different interface characteristics: cementless flat smooth, cementless flat porous\u2010coated, cementless flat porous\u2010coated with screws, cementless pegged porous\u2010coated, cementless pegged porous\u2010coated with screws, cemented pegged, and cemented pegged with screws. In all cases, the magnitude of the transverse expansion increased with higher applied loads. When the statistical analysis was restricted to the cementless interfaces, the presence\/absence of the porous coating, the presence\/absence of pegs, and the use of screws had no significant influence on tibial expansion. However, in an analysis including the cemented and cementless pegged components, tibial expansion was reduced with the use of screws. The magnitude of the interface motion due to these displacement incompatibilities was approximately fivefold lower than the amount of interface motion related to rigid body motion found in a separate study with the canine model. The measured expansion was similar in the intact tibiae and the implanted tibiae, suggesting that the transverse constraint in the canine proximal tibia must be provided by the surrounding cortical ring rather than the subchondral bone. \u00a9 1994 John Wiley &amp; Sons, Inc.<\/jats:p>","DOI":"10.1002\/jab.770050410","type":"journal-article","created":{"date-parts":[[2005,5,29]],"date-time":"2005-05-29T12:18:43Z","timestamp":1117369123000},"page":"349-352","source":"Crossref","is-referenced-by-count":10,"title":["Effects of fixation technique on displacement incompatibilities at the bone\u2013implant interface in cementless total knee replacement in a canine model"],"prefix":"10.1002","volume":"5","author":[{"given":"Aivars","family":"Berzins","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dale R.","family":"Sumner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas M.","family":"Turner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Raghu","family":"Natarajan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2004,8,30]]},"reference":[{"key":"e_1_2_1_2_2","first-page":"151","volume-title":"Bone ingrowth. Evarts","author":"Sumner D. R.","year":"1990"},{"key":"e_1_2_1_3_2","first-page":"135","volume-title":"Mechanical factors influencing ingrowth into the tibial components of total knee replacement","author":"Andriacchi T. P.","year":"1988"},{"key":"e_1_2_1_4_2","first-page":"38","article-title":"The mechanical stability of various noncemented tibial components","volume":"226","author":"Volz R. G.","year":"1988","journal-title":"Clin. Orthop."},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1002\/jab.770020206"},{"key":"e_1_2_1_6_2","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1097\/00003086-198902000-00015","article-title":"The effect of collar and distal stem fixation on micromotion of the femoral stem in uncemented total hip arthroplasty","volume":"239","author":"Whiteside L. A.","year":"1989","journal-title":"Clin. Orthop."},{"key":"e_1_2_1_7_2","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1097\/00003086-198912000-00017","article-title":"Rationale, experience, and results of long\u2010stem femoral prosthesis","volume":"249","author":"Gustilo R. B.","year":"1989","journal-title":"Clin. Orthop."},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1002\/jor.1100090219"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9290(87)90035-2"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-199274060-00005"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9290(94)90265-8"},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(89)80049-X"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1002\/jor.1100080108"},{"key":"e_1_2_1_14_2","doi-asserted-by":"crossref","unstructured":"Dujovne A.;Wevers H. W.Experimental measurements of proximal tibial displacements under load: comparison with FE models. Proc. XII Int. Congr. Biomech. Los Angeles;1989.","DOI":"10.1016\/0021-9290(89)90190-5"},{"key":"e_1_2_1_15_2","unstructured":"Goethgen C. B.;Konrath G.;Sumner D. R.Initial boneimplant displacements in the proximal tibia under conditions of rigid fixation in canines and humans.Eur. Soc. Biomech. 1990."},{"key":"e_1_2_1_16_2","unstructured":"Strickland A. B.;Natarajan R. N.;Andriacchi T. P.Transverse motion at the interface between the tibial component and bone in total knee replacement: an analytical model.Proc. 3rd J. ASCE\/ASME Mech. Conf. San Diego 1989:285\u2013289."},{"key":"e_1_2_1_17_2","first-page":"471","article-title":"Experimental validation of a finite element method for the prediction of boneprosthesis interface relative displacement","volume":"15","author":"Tissakht M.","year":"1990","journal-title":"Trans. ORS"},{"key":"e_1_2_1_18_2","first-page":"233","article-title":"Direct measurement of micromotion at the bone\u2010implant interface: the tibial component in a canine model","volume":"15","author":"Yang A.","year":"1990","journal-title":"Trans. ORS"},{"key":"e_1_2_1_19_2","doi-asserted-by":"publisher","DOI":"10.1002\/jor.1100070616"},{"key":"e_1_2_1_20_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.820270205"},{"key":"e_1_2_1_21_2","doi-asserted-by":"publisher","DOI":"10.1520\/JTE10084J"},{"key":"e_1_2_1_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9290(94)90226-7"}],"container-title":["Journal of Applied Biomaterials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fjab.770050410","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jab.770050410","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,24]],"date-time":"2023-10-24T04:00:46Z","timestamp":1698120046000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jab.770050410"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1994,12]]},"references-count":21,"journal-issue":{"issue":"4","published-print":{"date-parts":[[1994,12]]}},"alternative-id":["10.1002\/jab.770050410"],"URL":"https:\/\/doi.org\/10.1002\/jab.770050410","archive":["Portico"],"relation":{},"ISSN":["1045-4861","1549-9316"],"issn-type":[{"value":"1045-4861","type":"print"},{"value":"1549-9316","type":"electronic"}],"subject":[],"published":{"date-parts":[[1994,12]]}}}