{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,10,22]],"date-time":"2023-10-22T15:30:00Z","timestamp":1697988600152},"reference-count":32,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2004,9,13]],"date-time":"2004-09-13T00:00:00Z","timestamp":1095033600000},"content-version":"vor","delay-in-days":7987,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Biomed. Mater. Res."],"published-print":{"date-parts":[[1982,11]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>A comparative study of stress distributions in the component materials of a number of models of a prosthetically resurfaced tibia is presented. Although the geometry is idealized to be axisymmetric, the loadings for which the finite element analyses are performed are considered to be nonaxisymmetric, simulating more realistically the loading conditions <jats:italic>in vivo<\/jats:italic>. The different models are chosen with the view of determining the influence of changes in the prosthesis design on the induced stress distribution in the component materials. The changes considered are in the thickness of the cement and the cement\u2010bone composite layers, and in the shape of the prosthesis. Experimentally measured values of strains are compared with the analytically predicted values to check the validity of the assumptions used in the finite element modeling. The comparison of induced stresses in the different materials reveals the desirability, from a mechanical behavior point of view, of introducing a cement\u2010bone composite layer and using a prosthesis with domed subsurface in the fixation system. It is shown that for a model incorporating these features, considerable reduction of stresses in the cement, in its bulk and at its interface with the prosthesis plate, is achieved. The reduced stresses can be expected to have beneficial effects on the long\u2010term behavior of the cement and its interfaces in the fixation system.<\/jats:p>","DOI":"10.1002\/jbm.820160616","type":"journal-article","created":{"date-parts":[[2004,12,31]],"date-time":"2004-12-31T12:36:34Z","timestamp":1104496594000},"page":"929-949","source":"Crossref","is-referenced-by-count":11,"title":["Effect of a cement\u2010bone composite layer and prosthesis geometry on stresses in a prosthetically resurfaced tibia"],"prefix":"10.1002","volume":"16","author":[{"given":"S. C.","family":"Shrivastava","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A. M.","family":"Ahmed","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Shirazi\u2010Adl","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D. L.","family":"Burke","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2004,9,13]]},"reference":[{"key":"e_1_2_1_2_2","unstructured":"D. B.Kettelkamp \u201cKnee Implants \u201d inTotal Joint Replacement Proceedings of a Workshop held at Northwes University Chicago March 3 1977 C. L. Compere and J. L. Lewis Eds. Northwestern University Rehabilitation Engineering Program Chicago IL 1977 pp.62\u201375."},{"key":"e_1_2_1_3_2","unstructured":"W. H.Harris \u201cLoosening \u201d inThe Hip Proceedings of the Sixth Open Scientific Meeting of the Hip Society C.V. Mosby St. Louis 1978 pp.162\u2013175."},{"key":"e_1_2_1_4_2","unstructured":"J.Miller D. L.Burke J. W.Stachiewicz A. M.Ahmed andL. C.Kelebay \u201cPathophysiology of Loosening of Femoral Components in Total Hip Arthroplasty \u201d inThe Hip Proceedings of the Sixth Open Scientific Meeting of the Hip Society C.V. Mosby St. Louis 1978 pp.64\u201386."},{"key":"e_1_2_1_5_2","unstructured":"J.Miller D. L.Burke L. C.Kelebay andW.Krause \u201cImproved Fixation of Knee Arthroplasty Components to Prevent Loosening \u201d Scientific Exhibit 46th Annual Meeting of the American Academy of Orthopaedic Surgeons San Francisco Feb. 22\u201327 1979.J.Miller D. L.Burke L.Kelebay andW.Krause \u201cNew Techniques and Instrumentation for Improved Fixation of Hip and Knee Implants \u201d Scientific Exhibit 47th Annual Meeting of the American Academy of Orthopaedic Surgeons Atlanta Feb. 7\u201312 1980."},{"key":"e_1_2_1_6_2","first-page":"394","volume-title":"Biomechanics V\u2010A","author":"McNeice G. M.","year":"1976"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-197658050-00006"},{"key":"e_1_2_1_8_2","unstructured":"G. M.McNeice \u201cRequirements and Review of Existing Finite Element Models for Femoral Component Analysis in Total Hip Repment \u201d inProceedings of the International Conference on Finite Elements in Biomechanics Vol. 2 B. R. Simon Ed. University of Arizona College of Engineering Tucson 1980 pp.463\u2013486."},{"key":"e_1_2_1_9_2","unstructured":"I. G.Clarke T. A. W.Gruen R. R.Tarr andA.Sarmiento \u201cFinite Element Analysis studies of total hips Versus Clinical Reality \u201d inProceedings of the International Conference on Finite Elements in Biomechanics Vol. 2 B. R. Simon Ed. University of Arizona College of Engineering Tucson 1980 pp.487\u2013510."},{"key":"e_1_2_1_10_2","first-page":"55","article-title":"Stress Analysis of Some Features of Knee Prostheses by Finite Element","volume":"2","author":"Lewis J. L.","year":"1977","journal-title":"Trans. 23rd Ann. Meet., Orthop. Res. Soc."},{"key":"e_1_2_1_11_2","first-page":"205","volume-title":"Proceedings of the 1977 Biomechanics Symposium","author":"Chao E. Y.","year":"1977"},{"key":"e_1_2_1_12_2","first-page":"17","article-title":"Interface Stresses in a Prosthesis\u2010Tibia Structure with Varying Bone Properties","volume":"3","author":"Askew M. J.","year":"1978","journal-title":"Trans. 24th Ann. Meet. Orthop. Res. Soc."},{"key":"e_1_2_1_12_3","first-page":"97","article-title":"The Effect of Post Geometry, Material and Location on Interface Stress Levels in Tibial Components of Total Knee Prosthesis","volume":"4","author":"Askew M. J.","year":"1979","journal-title":"Trans. 25th Ann. Meet. Orthop. Res. Soc."},{"key":"e_1_2_1_13_2","first-page":"71","volume-title":"Proceedings of the 1979 Biomechanics Symposium","author":"Hayes W. C.","year":"1979"},{"key":"e_1_2_1_14_2","volume-title":"Mechanical Properties of Bone","author":"Evans F. G.","year":"1973"},{"key":"e_1_2_1_15_2","first-page":"41","article-title":"Young's Modulus of Living Human Bone","volume":"6","author":"Brown N.","year":"1981","journal-title":"Trans. 27th Ann. Meet. Orthop. Res. Soc."},{"key":"e_1_2_1_16_2","first-page":"44","article-title":"Cortical Bone Fatigue\u2014The Effect of Strain Range, Stress Range, and Elastic Modulus","volume":"6","author":"Carter D. R.","year":"1981","journal-title":"Trans. 27th Ann. Meet. Orthop. Res. Soc."},{"key":"e_1_2_1_17_2","volume-title":"Biomechanical Studies of the Musculoskeletal System","author":"Evans F. G.","year":"1961"},{"key":"e_1_2_1_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9290(73)90006-7"},{"key":"e_1_2_1_19_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-197557030-00017"},{"key":"e_1_2_1_20_2","first-page":"133","article-title":"Characterization of the Cement\u2010Bone Composite","volume":"6","author":"Krause W.","year":"1981","journal-title":"Trans. 27th Ann. Meet. Orthop. Res. Soc."},{"key":"e_1_2_1_21_2","first-page":"135","article-title":"Compressive Behavior of Bone\u2010Cement Composites","volume":"6","author":"Hayes W. C.","year":"1981","journal-title":"Trans. 27th Ann. Meet. Orthop. Res. Soc."},{"key":"e_1_2_1_22_2","volume-title":"Implants in Surgery","author":"Williams D. F.","year":"1973"},{"key":"e_1_2_1_23_2","first-page":"511","volume-title":"Proceedings of the International Conference on Finite Elements in Biomechanics","author":"Tarr R.","year":"1980"},{"key":"e_1_2_1_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9290(79)90032-0"},{"key":"e_1_2_1_25_2","first-page":"549","volume-title":"Proceedings of the International Conference on Finite Elements in Biomechanics","author":"Rohlmann A.","year":"1980"},{"key":"e_1_2_1_26_2","doi-asserted-by":"publisher","DOI":"10.1115\/1.3424663"},{"key":"e_1_2_1_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9290(70)90050-3"},{"key":"e_1_2_1_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9290(75)90089-5"},{"key":"e_1_2_1_29_2","volume-title":"Mechanical Design in Organisms","author":"Wainwright S. A.","year":"1976"},{"key":"e_1_2_1_30_2","first-page":"114","article-title":"Mechanical Properties of Poly(methyl Methacrylate) Bone Cement","volume":"6","author":"Robinson R. P.","year":"1981","journal-title":"Trans. 27th Ann. Meet. Orthop. Res. Soc."},{"key":"e_1_2_1_31_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.820140510"},{"key":"e_1_2_1_32_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.820150205"}],"container-title":["Journal of Biomedical Materials Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fjbm.820160616","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jbm.820160616","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,19]],"date-time":"2023-10-19T03:13:58Z","timestamp":1697685238000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jbm.820160616"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1982,11]]},"references-count":32,"journal-issue":{"issue":"6","published-print":{"date-parts":[[1982,11]]}},"alternative-id":["10.1002\/jbm.820160616"],"URL":"https:\/\/doi.org\/10.1002\/jbm.820160616","archive":["Portico"],"relation":{},"ISSN":["0021-9304","1097-4636"],"issn-type":[{"value":"0021-9304","type":"print"},{"value":"1097-4636","type":"electronic"}],"subject":[],"published":{"date-parts":[[1982,11]]}}}