{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,3]],"date-time":"2026-10-03T18:00:05Z","timestamp":1791050405421,"version":"4.1.0"},"reference-count":77,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2005,4,19]],"date-time":"2005-04-19T00:00:00Z","timestamp":1113868800000},"content-version":"vor","delay-in-days":7840,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Biomed. Mater. Res."],"published-print":{"date-parts":[[1983,11]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Using canine models, a representative selection of polyester or Dacron vascular prostheses, including woven, knitted, and velour types, were evaluated for their relative healing characteristics and for their structural changes during implantation. Following residence periods ranging from 4 h to 6 months at the site of the thoracic aorta, the dogs were sacrified, and the grafts were excized for measurement of the thrombogenicity of the flow surface and for pathological examination by light microscopy and SEM. The kidneys were also removed and examined for infarcts caused by any trapped circulating emboli. The extent of healing, the presence of embolizing nuclei, and the thrombogenicity and morphology of the lumen surface were also assessed. The healing characteristics of each type of device proved similar. Velour fabrics exhibited more extensive encapsulation, but frequently their internal capsules failed to incorporate all the fibers. In all cases, cellular development on the lumen was limited to areas contiguous to the anastomoses. The initial porosity of the devices as measured by water permeability did not appear to influence the healing sequence to a significant extent. The grafts did exhibit differences in structural stability depending on whether they were of a knitted or woven construction. We suggest that users consider these different mechanical and structural properties when making their choice of a graft. Despite these differences, we believe that the healing process is far more host dependent than graft dependent.<\/jats:p>","DOI":"10.1002\/jbm.820170614","type":"journal-article","created":{"date-parts":[[2005,5,27]],"date-time":"2005-05-27T19:13:05Z","timestamp":1117221185000},"page":"1049-1077","source":"Crossref","is-referenced-by-count":42,"title":["Polyester prostheses as substitutes in the thoracic aorta of dogs. I. Evaluation of commercial prostheses"],"prefix":"10.1002","volume":"17","author":[{"given":"R.","family":"Guidoin","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C.","family":"Gosselin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L.","family":"Martin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Marois","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"F.","family":"Laroche","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"King","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K.","family":"Gunasekera","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D.","family":"Domurado","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M. F.","family":"Sigot\u2010Luizard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.","family":"Blais","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2005,4,19]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9610(79)90083-7"},{"key":"e_1_2_1_3_2","first-page":"71","article-title":"An evaluation of synthetic materials and fabrics suitable for blood vessel replacement","volume":"38","author":"Deterling R. A.","year":"1955","journal-title":"Surgery"},{"key":"e_1_2_1_4_2","first-page":"30","article-title":"The current status of femoropopliteal bypass for arterio\u2010sclerotic occlusive disease. A panel discussion","volume":"79","author":"Barker W. P.","year":"1976","journal-title":"Surgery"},{"key":"e_1_2_1_5_2","first-page":"365","article-title":"The great saphenous vein used in situ as an arterial shunt after vein valve extirpation. The method and immediate results","volume":"128","author":"Hall K. V.","year":"1964","journal-title":"Acta Chir. Scand."},{"key":"e_1_2_1_6_2","first-page":"171","article-title":"La technique de la greffe veineuse in situ dans la chirurgie art\u00e9rielle restauratrice des membres inf\u00e9rieurs","volume":"115","author":"Langeron P.","year":"1978","journal-title":"J. Chir. (Paris)"},{"key":"e_1_2_1_7_2","volume-title":"A statistical summary of the results of femoropopliteal bypass surgery published during 1965 to 1979","author":"Mehta S.","year":"1979"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM198002283020904"},{"key":"e_1_2_1_9_2","first-page":"485","article-title":"The use of expanded microporous polytetrafluoroethylene for limb salvage. A preliminary report","volume":"79","author":"Campbell C. D.","year":"1976","journal-title":"Surgery"},{"key":"e_1_2_1_10_2","first-page":"177","volume-title":"Biocompatibility of Clinical Implant Materials","author":"King M.","year":"1981"},{"key":"e_1_2_1_11_2","first-page":"5","volume-title":"Vascular grafts","author":"Callow A. D.","year":"1978"},{"key":"e_1_2_1_12_2","first-page":"331","article-title":"Performance of materials as prosthetic blood vessels","volume":"48","author":"Wesolowski S. A.","year":"1972","journal-title":"Bull. N.Y. Acad. Med."},{"key":"e_1_2_1_13_2","first-page":"91","article-title":"Porosity: primary determinant of ultimate fate of synthetic vascular grafts","volume":"50","author":"Wesolowski S. A.","year":"1961","journal-title":"Surgery"},{"key":"e_1_2_1_14_2","first-page":"544","article-title":"Factors contributing to long\u2010term failures in human vascular prosthetic grafts","volume":"5","author":"Wesolowski S. A.","year":"1964","journal-title":"J. Cardiovasc. Surg."},{"key":"e_1_2_1_15_2","first-page":"40","article-title":"Evaluation of a new vascular prosthesis with optimal specifications","volume":"59","author":"Wesolowski S. A.","year":"1966","journal-title":"Surgery"},{"key":"e_1_2_1_16_2","first-page":"78","article-title":"A very thin, porous, knitted arterial prosthesis. Experimental data and early clinical assessment","volume":"65","author":"Sauvage L. F.","year":"1969","journal-title":"Surgery"},{"key":"e_1_2_1_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9610(75)90342-6"},{"key":"e_1_2_1_18_2","first-page":"945","article-title":"A transmission and scanning electron microscopic study of luminal surfaces in Dacron and autogenous vein bypasses in man and dog","volume":"74","author":"Reichle F. S.","year":"1973","journal-title":"Surgery"},{"key":"e_1_2_1_19_2","first-page":"208","article-title":"A scanning and transmission electron microscope study of the luminal coating on Dacron prostheses in the canine thoracic aorta","volume":"85","author":"Stewart G. J.","year":"1975","journal-title":"J. Lab. Clin. Med."},{"key":"e_1_2_1_20_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1749-6632.1977.tb41765.x"},{"key":"e_1_2_1_21_2","first-page":"314","article-title":"Velour vascular prosthesis","volume":"20","author":"Lindenauer S. M.","year":"1974","journal-title":"Trans. Am. Soc. Artif. Intern. Organs"},{"key":"e_1_2_1_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/0090-4295(75)90067-9"},{"key":"e_1_2_1_23_2","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1016\/S0039-6109(16)40245-8","article-title":"Future directions in the development of arterial prosthesis for small and medium caliber arteries","volume":"54","author":"Sauvage L. R.","year":"1974","journal-title":"Surg. Clin. North Am."},{"key":"e_1_2_1_24_2","first-page":"197","volume-title":"Vascular grafts","author":"Cooley D. A.","year":"1978"},{"key":"e_1_2_1_25_2","first-page":"177","volume-title":"Vascular grafts","author":"Noon G. P.","year":"1978"},{"key":"e_1_2_1_26_2","doi-asserted-by":"publisher","DOI":"10.1177\/153857448001400307"},{"key":"e_1_2_1_27_2","first-page":"223","article-title":"Regeneration of endothelium in knitted and velour Dacron vascular grafts in dogs","volume":"22","author":"Hertzer N. R.","year":"1981","journal-title":"J. Cardiovasc. Surg."},{"key":"e_1_2_1_28_2","first-page":"168","article-title":"Comparative studies on healing of crimped and flat arterial prostheses","volume":"11","author":"Lucer C.","year":"1972","journal-title":"Pol. Med. J."},{"key":"e_1_2_1_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/0022-4804(75)90082-7"},{"key":"e_1_2_1_30_2","first-page":"596","article-title":"The effects of crimping on the healing of prosthetic arterial grafts","volume":"21","author":"Herring M.","year":"1980","journal-title":"J. Cardiovasc. Surg."},{"key":"e_1_2_1_31_2","first-page":"215","article-title":"Evaluation of chemical compacting techniques on the performance thrombosis rate, histology and healing of experimental similarly fabricated Dacron prostheses","volume":"24","author":"Sawyer P. N.","year":"1978","journal-title":"Trans. Am. Soc. Artif. Intern. Organs"},{"key":"e_1_2_1_32_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.820130611"},{"key":"e_1_2_1_33_2","doi-asserted-by":"publisher","DOI":"10.1002\/bjs.1800660414"},{"key":"e_1_2_1_34_2","first-page":"H568","article-title":"Dynamic compliance of arterial grafts","volume":"233","author":"Baird R. N.","year":"1977","journal-title":"Am. J. Physiol."},{"key":"e_1_2_1_35_2","doi-asserted-by":"crossref","first-page":"894","DOI":"10.1016\/S0022-5223(19)39605-9","article-title":"Pattern of arrangement of smooth muscle cells in neo\u2010intima of synthetic vascular prostheses","volume":"75","author":"Noishiki Y.","year":"1978","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"e_1_2_1_36_2","first-page":"301","volume-title":"Biomechanics of Medical Devices","author":"Gozna E. R.","year":"1981"},{"key":"e_1_2_1_37_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000658-197811000-00005"},{"key":"e_1_2_1_38_2","first-page":"597","article-title":"Surface characteristics of Dacron vascular prostheses implanted in humans. A scanning electron microscope study","volume":"2","author":"Guidoin R.","year":"1978","journal-title":"Scanning Electron Microsc."},{"key":"e_1_2_1_39_2","first-page":"12","article-title":"Surface thrombogenicity of arterial prostheses","volume":"136","author":"Yates S. G.","year":"1973","journal-title":"Surg. Gynecol. Obstet."},{"key":"e_1_2_1_40_2","doi-asserted-by":"publisher","DOI":"10.1016\/0022-4804(77)90130-5"},{"key":"e_1_2_1_41_2","unstructured":"J. M.Hartigan personal communication 1977."},{"key":"e_1_2_1_42_2","unstructured":"M.King unpublished data."},{"key":"e_1_2_1_43_2","doi-asserted-by":"publisher","DOI":"10.1001\/archsurg.1974.01360050092020"},{"key":"e_1_2_1_44_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1749-6632.1977.tb41795.x"},{"key":"e_1_2_1_45_2","first-page":"3","article-title":"Les proth\u00e8ses en poly\u00e9thyl\u00e8ne t\u00e9r\u00e9phtalate (Dacron) comme substituts art\u00e9riels. Evaluation des greffes commerciales comme substituts de l'aorte abdominale de chiens","volume":"5","author":"Guidoin R.","year":"1980","journal-title":"J. Mal. Vasc. (Paris)"},{"key":"e_1_2_1_46_2","doi-asserted-by":"publisher","DOI":"10.3109\/10731197709118667"},{"key":"e_1_2_1_47_2","doi-asserted-by":"publisher","DOI":"10.1016\/0026-0495(79)90044-1"},{"key":"e_1_2_1_48_2","doi-asserted-by":"publisher","DOI":"10.1177\/000331977802900706"},{"key":"e_1_2_1_49_2","first-page":"715","article-title":"Analyse des facteurs de risque de l'art\u00e9riopathie oblit\u00e9rante des membres inf\u00e9rieurs. R\u00e9sultats pr\u00e9liminaires","volume":"110","author":"Forest J. C.","year":"1981","journal-title":"Union Med. Can."},{"key":"e_1_2_1_50_2","doi-asserted-by":"publisher","DOI":"10.1001\/archsurg.1979.01370300041005"},{"key":"e_1_2_1_51_2","first-page":"169","volume-title":"Grafts materials in vascular surgery","author":"Edwards W. S.","year":"1978"},{"key":"e_1_2_1_52_2","doi-asserted-by":"publisher","DOI":"10.1520\/STP35938S"},{"key":"e_1_2_1_53_2","doi-asserted-by":"crossref","first-page":"769","DOI":"10.1097\/00000658-195110000-00021","article-title":"The viability of long blood vessel grafts","volume":"134","author":"McCune W. S.","year":"1954","journal-title":"Ann. Surg."},{"key":"e_1_2_1_54_2","doi-asserted-by":"publisher","DOI":"10.1001\/archsurg.1961.01300070012002"},{"key":"e_1_2_1_55_2","first-page":"403","article-title":"La pr\u00e9coagulation des proth\u00e8ses vasculaires en Dacron tiss\u00e9","volume":"117","author":"Topping C.","year":"1980","journal-title":"J. Chir. (Paris"},{"issue":"1","key":"e_1_2_1_56_2","first-page":"42","article-title":"Biochemical studies on Dacron arterial prostheses","volume":"24","author":"Robert A. M.","year":"1976","journal-title":"Pathol. Biol."},{"key":"e_1_2_1_57_2","first-page":"63","article-title":"M\u00e9canisme de la synth\u00e8se des glycoconjugu\u00e9s au niveau des parois art\u00e9rielles apr\u00e8s contact avec des mat\u00e9riaux alloplastiques","volume":"36","author":"Guidollet J.","year":"1978","journal-title":"Ann. Biol. Clin. (Paris)"},{"key":"e_1_2_1_58_2","first-page":"1013","article-title":"The organization of isolated mural thrombi in aortic grafts","volume":"51","author":"Still W. J. S.","year":"1967","journal-title":"Am. J. Pathol."},{"key":"e_1_2_1_59_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(78)92618-1"},{"key":"e_1_2_1_60_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF01968247"},{"key":"e_1_2_1_61_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000658-197711000-00009"},{"key":"e_1_2_1_62_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1749-6632.1977.tb41778.x"},{"key":"e_1_2_1_63_2","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9150(73)90103-2"},{"key":"e_1_2_1_64_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000658-197409000-00013"},{"key":"e_1_2_1_65_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.RES.36.1.58"},{"key":"e_1_2_1_66_2","first-page":"15","article-title":"The aortic intima. II. Repair of the aortic lining after mechanical denudation","volume":"81","author":"Schwartz S. M.","year":"1975","journal-title":"Am. J. Pathol."},{"key":"e_1_2_1_67_2","doi-asserted-by":"publisher","DOI":"10.1001\/archsurg.1979.01370360073009"},{"key":"e_1_2_1_68_2","doi-asserted-by":"publisher","DOI":"10.1177\/153857448101500207"},{"key":"e_1_2_1_69_2","doi-asserted-by":"publisher","DOI":"10.1001\/archsurg.1979.01370350098011"},{"key":"e_1_2_1_70_2","doi-asserted-by":"publisher","DOI":"10.1177\/004051755602600408"},{"key":"e_1_2_1_71_2","first-page":"167","article-title":"Formation an\u00e9vrismale sur proth\u00e8se synth\u00e9tique: analyse pathologique, structurale et chimique d'une greffe en polyester apr\u00e8s 84 mois d'implantation","volume":"6","author":"Godard F.","year":"1981","journal-title":"J. Mal. Vasc. (Paris)"},{"key":"e_1_2_1_72_2","first-page":"31","article-title":"Synthetic fibre degradation in living organism","volume":"16","author":"Dvorak J.","year":"1965","journal-title":"Text. Sci. Res."},{"key":"e_1_2_1_73_2","first-page":"29","volume-title":"Implant retrieval: material and biological analysis","author":"Guidoin R.","year":"1981"},{"key":"e_1_2_1_74_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.59.1.8"},{"key":"e_1_2_1_75_2","doi-asserted-by":"publisher","DOI":"10.1177\/000331977802901004"},{"key":"e_1_2_1_76_2","first-page":"357","article-title":"Les facteurs aggravants de l'art\u00e9riopathie des membres inf\u00e9rieurs chez le diab\u00e9tique","volume":"32","author":"Cirette B.","year":"1980","journal-title":"Ang\u00e9iologie (Paris)"},{"key":"e_1_2_1_77_2","doi-asserted-by":"publisher","DOI":"10.1002\/bjs.1800650415"},{"key":"e_1_2_1_78_2","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/S0022-5223(19)40386-3","article-title":"The effect of continued cigarette smoking on the patency of synthetic vascular grafts in Leriche syndrome","volume":"70","author":"Robicsek F.","year":"1975","journal-title":"J. Thorac. Cardiovasc. Surg."}],"container-title":["Journal of Biomedical Materials Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fjbm.820170614","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jbm.820170614","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,19]],"date-time":"2023-10-19T17:07:19Z","timestamp":1697735239000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jbm.820170614"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1983,11]]},"references-count":77,"journal-issue":{"issue":"6","published-print":{"date-parts":[[1983,11]]}},"alternative-id":["10.1002\/jbm.820170614"],"URL":"https:\/\/doi.org\/10.1002\/jbm.820170614","archive":["Portico"],"relation":{},"ISSN":["0021-9304","1097-4636"],"issn-type":[{"value":"0021-9304","type":"print"},{"value":"1097-4636","type":"electronic"}],"subject":[],"published":{"date-parts":[[1983,11]]}}}