{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T07:34:55Z","timestamp":1784619295968,"version":"3.55.0"},"reference-count":32,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2007,12,7]],"date-time":"2007-12-07T00:00:00Z","timestamp":1196985600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Biomedical Materials Res"],"published-print":{"date-parts":[[2008,9,15]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Corroding metals made of magnesium alloys represent a new class of degradable implants for musculoskeletal surgery. These implants may be associated with skin sensitizing reactions because of the release of metal ions. This study was conducted to compare the sensitizing potential of four different magnesium alloys (AZ31, AZ91, WE43, and LAE442) to current implant materials such as titanium (TiAl6V4) and a degradable polymer (SR\u2010PLA96). Solutions and solid chips of these materials were prepared and tested in 156 guinea pigs according to the Magnusson\u2013Kligman test. A standard allergen (hydroxy\u2010cinnamon\u2010aldehyde) causing allergic erythema was used as positive control and a standard irritant (sodium\u2010lauryl\u2010sulfate) causing local skin irritation for less than 24 h was used as negative control. All erythema were graded immediately and 24 h after patch removal by three independent observers. Histomorphological analyses were performed on skin biopsies taken 24 h after patch removal. We found that initial erythema in animals treated with solid chips diminished within 24 h and were caused by local skin irritation. Local skin irritation was also determined in erythema remaining for 24 h after patch removal in animals treated with dissolved test materials. No allergenic reactions according to the histomorphological criteria were observed in skin biopsies. We conclude that no skin sensitizing potential were detected for standard materials as well as for all tested magnesium alloys by the used methods. \u00a9 2007 Wiley Periodicals, Inc. J Biomed Mater Res, 2008<\/jats:p>","DOI":"10.1002\/jbm.a.31713","type":"journal-article","created":{"date-parts":[[2007,12,7]],"date-time":"2007-12-07T21:46:51Z","timestamp":1197064011000},"page":"1041-1047","source":"Crossref","is-referenced-by-count":67,"title":["Evaluation of the skin sensitizing potential of biodegradable magnesium alloys"],"prefix":"10.1002","volume":"86A","author":[{"given":"Frank","family":"Witte","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Inken","family":"Abeln","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elinor","family":"Switzer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Volker","family":"Kaese","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrea","family":"Meyer\u2010Lindenberg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Henning","family":"Windhagen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2007,12,7]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(00)90055-0"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/0267-6605(92)90083-6"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-662-06077-3"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2004.09.049"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1001\/jama.1938.02790530018007"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200103000-00017"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199605000-00009"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1038\/jid.1969.42"},{"key":"e_1_2_6_10_2","first-page":"179","volume-title":"Richtlinie des Europ\u00e4ischen Parlaments und des Rates","author":"OECD","year":"1993"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.1995.tb00801.x"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1159\/000251252"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/0142-9612(88)90053-1"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1111\/1523-1747.ep12496465"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.1996.tb02173.x"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1111\/1523-1747.ep12876210"},{"key":"e_1_2_6_17_2","first-page":"1","article-title":"The effect of selected immunomodulating agents on experimental contact reactions","volume":"116","author":"Anderson C","year":"1985","journal-title":"Acta Derm Venereol Suppl (Stockh)"},{"key":"e_1_2_6_18_2","doi-asserted-by":"crossref","first-page":"129","DOI":"10.2340\/0001555559129134","article-title":"Measurement and differentiation of the cellular infiltrate in experimental allergic contact dermatitis","volume":"59","author":"Groth O","year":"1979","journal-title":"Acta Derm Venereol"},{"key":"e_1_2_6_19_2","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0536.2000.042004216.x"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2005.07.037"},{"key":"e_1_2_6_21_2","doi-asserted-by":"publisher","DOI":"10.1034\/j.1398-9995.2000.00619.x"},{"key":"e_1_2_6_22_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF00575233"},{"key":"e_1_2_6_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0300-483X(99)00145-6"},{"key":"e_1_2_6_24_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.1981.tb04058.x"},{"key":"e_1_2_6_25_2","first-page":"426","article-title":"Experimental studies on metal dermatitis in guinea pigs","volume":"44","author":"Turk JL","year":"1969","journal-title":"G Ital Dermatol Minerva Dermatol"},{"key":"e_1_2_6_26_2","first-page":"1","volume-title":"International Standard 10993\u201010:1995 (E), Biological evaluation of medical devices","author":"ISO","year":"1995"},{"key":"e_1_2_6_27_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.1986.tb01315.x"},{"key":"e_1_2_6_28_2","doi-asserted-by":"publisher","DOI":"10.1084\/jem.138.5.1144"},{"key":"e_1_2_6_29_2","doi-asserted-by":"crossref","first-page":"1543","DOI":"10.1001\/archderm.1977.01640110063009","article-title":"Cell populations in experimental contact dermatitis","volume":"113","author":"Hunziker N","year":"1977","journal-title":"Arch Dermatol"},{"key":"e_1_2_6_30_2","doi-asserted-by":"publisher","DOI":"10.1159\/000233920"},{"key":"e_1_2_6_31_2","doi-asserted-by":"publisher","DOI":"10.1084\/jem.132.3.558"},{"key":"e_1_2_6_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/0048-9697(91)90105-N"},{"key":"e_1_2_6_33_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-4632.2004.01983.x"}],"container-title":["Journal of Biomedical Materials Research Part A"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fjbm.a.31713","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jbm.a.31713","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,16]],"date-time":"2023-10-16T08:57:02Z","timestamp":1697446622000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jbm.a.31713"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,12,7]]},"references-count":32,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2008,9,15]]}},"alternative-id":["10.1002\/jbm.a.31713"],"URL":"https:\/\/doi.org\/10.1002\/jbm.a.31713","archive":["Portico"],"relation":{},"ISSN":["1549-3296","1552-4965"],"issn-type":[{"value":"1549-3296","type":"print"},{"value":"1552-4965","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,12,7]]}}}