{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T16:41:23Z","timestamp":1791304883002,"version":"4.3.1"},"reference-count":106,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2008,5,28]],"date-time":"2008-05-28T00:00:00Z","timestamp":1211932800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Biomedical Materials Res"],"published-print":{"date-parts":[[2009,8]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Total joint replacement is one of the most clinically successful, cost\u2010effective surgical procedures. These operations have been shown to improve pain, function and mobility in patients with end\u2010stage arthritis. However, joint replacements that will allow full, unrestricted, high impact activities and last the patient's lifetime have not yet been devised. This is due to biocompatibility issues related to material science, biomechanics, and host responses. In this review, three issues that are highly pertinent to biocompatibility of joint replacements are examined. These topics include how implants initially osseointegrate within bone, potential adverse effects of byproducts of wear that can lead to aseptic loosening and perprosthetic osteolysis, and the potential for new bearing surfaces to extend the lifetime of implants. A clear understanding of these important issues will facilitate the development of novel strategies to improve the longevity and function of implants for joint replacement in the future. \u00a9 2008 Wiley Periodicals, Inc. J Biomed Mater Res, 2009<\/jats:p>","DOI":"10.1002\/jbm.a.32063","type":"journal-article","created":{"date-parts":[[2008,5,28]],"date-time":"2008-05-28T21:18:23Z","timestamp":1212009503000},"page":"603-618","source":"Crossref","is-referenced-by-count":74,"title":["Biocompatibility of total joint replacements: A review"],"prefix":"10.1002","volume":"90A","author":[{"given":"Stuart B.","family":"Goodman","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Enrique","family":"G\u00f3mez Barrena","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michiaki","family":"Takagi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yrjo T.","family":"Konttinen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2008,5,28]]},"reference":[{"key":"e_1_2_8_2_2","volume-title":"Implant Wear in Total Joint Replacement","author":"Wright T","year":"2001"},{"key":"e_1_2_8_3_2","first-page":"113","article-title":"Osseointegration of cemented and noncemented implants in artificial hip replacement: Long\u2010term findings in man","volume":"9","author":"Willert HG","year":"1999","journal-title":"J Long Term Eff Med Implants"},{"key":"e_1_2_8_4_2","first-page":"77","article-title":"Osseointegration of total hip arthroplasties: Studies in humans and adults","volume":"9","author":"Song Y","year":"1999","journal-title":"J Long\u2010Term Eff Med Implants"},{"key":"e_1_2_8_5_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.76B6.7983118"},{"key":"e_1_2_8_6_2","first-page":"56","article-title":"Roentgen stereophotogrammetric analysis of prosthetic fixation in the hip and knee joint","volume":"276","author":"Ryd L","year":"1992","journal-title":"Clin Orthop"},{"key":"e_1_2_8_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ocl.2004.06.012"},{"key":"e_1_2_8_8_2","doi-asserted-by":"publisher","DOI":"10.3109\/02844316909036699"},{"key":"e_1_2_8_9_2","doi-asserted-by":"publisher","DOI":"10.3109\/17453678709146401"},{"key":"e_1_2_8_10_2","first-page":"167","volume-title":"Clinical Applications of Biomaterials. Advances in Biomaterials","author":"Albrektsson T","year":"1982"},{"key":"e_1_2_8_11_2","first-page":"119","article-title":"The nature of the bone\u2014Implant interface. The lessons learned from implant retrieval and analysis in man and experimental animal","volume":"20","author":"Boss JH","year":"1994","journal-title":"Med Prog Through Technol"},{"key":"e_1_2_8_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199810001-00006"},{"key":"e_1_2_8_13_2","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1097\/00003086-198607000-00023","article-title":"Observation on the effect of movement on bone ingrowth into porous surfaced implants","volume":"208","author":"Pilliar RM","year":"1986","journal-title":"Clin Orthop"},{"key":"e_1_2_8_14_2","first-page":"31","article-title":"Biomaterials and biocompatibility","volume":"4","author":"Williams DF","year":"1976","journal-title":"Med Prog Technol"},{"key":"e_1_2_8_15_2","first-page":"10","article-title":"Revisiting the definition of biocompatibility","volume":"14","author":"Williams D","year":"2003","journal-title":"Med Device Technol"},{"key":"e_1_2_8_16_2","first-page":"296","volume-title":"Biomaterials Science","author":"Anderson JM","year":"2004"},{"key":"e_1_2_8_17_2","first-page":"401","volume-title":"Orthopaedic Basic Science","author":"Jacobs JJ","year":"2000"},{"key":"e_1_2_8_18_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199612000-00003"},{"key":"e_1_2_8_19_2","doi-asserted-by":"publisher","DOI":"10.1002\/jor.1100120508"},{"key":"e_1_2_8_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ocl.2004.08.001"},{"key":"e_1_2_8_21_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-197509000-00032"},{"key":"e_1_2_8_22_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-198365050-00001"},{"key":"e_1_2_8_23_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-198007000-00045"},{"key":"e_1_2_8_24_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.820291213"},{"key":"e_1_2_8_25_2","doi-asserted-by":"publisher","DOI":"10.1177\/08959374990130011301"},{"key":"e_1_2_8_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2007.02.024"},{"key":"e_1_2_8_27_2","doi-asserted-by":"publisher","DOI":"10.1177\/039139880402700806"},{"key":"e_1_2_8_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.gene.2005.10.028"},{"key":"e_1_2_8_29_2","doi-asserted-by":"publisher","DOI":"10.1023\/B:ABME.0000017536.10767.0f"},{"key":"e_1_2_8_30_2","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1177\/039139880402700802","article-title":"Biomedical coatings to improve the tissue\u2010biomaterial interface","volume":"7","author":"Rizzi G","year":"2004","journal-title":"Int J Artif Organs"},{"key":"e_1_2_8_31_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.820260803"},{"key":"e_1_2_8_32_2","doi-asserted-by":"publisher","DOI":"10.1243\/0954411981533917"},{"key":"e_1_2_8_33_2","doi-asserted-by":"publisher","DOI":"10.1517\/14712598.4.7.1015"},{"key":"e_1_2_8_34_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.E.00846"},{"key":"e_1_2_8_35_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-642-67013-8"},{"key":"e_1_2_8_36_2","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1097\/00003086-198912000-00015","article-title":"Biomechanical and histological investigation of cemented total hip arthroplasties: A study of autopsy retrieved femurs after in vivo cycling","volume":"249","author":"Maloney WJ","year":"1989","journal-title":"Clin Orthop"},{"key":"e_1_2_8_37_2","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1097\/00003086-199009000-00014","article-title":"Osteolysis in alloarthroplasty of the hip. The role of bone cement fragmentation","volume":"258","author":"Willert HG","year":"1990","journal-title":"Clin Orthop Relat Res"},{"key":"e_1_2_8_38_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-199072020-00014"},{"key":"e_1_2_8_39_2","doi-asserted-by":"publisher","DOI":"10.1038\/41131"},{"key":"e_1_2_8_40_2","doi-asserted-by":"publisher","DOI":"10.1002\/jor.1100170603"},{"key":"e_1_2_8_41_2","doi-asserted-by":"publisher","DOI":"10.1177\/039139889301601103"},{"key":"e_1_2_8_42_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.blo.0000175715.68624.3d"},{"key":"e_1_2_8_43_2","first-page":"8","article-title":"Forces transmitted by joints in the human body","volume":"181","author":"Paul JP","year":"1967","journal-title":"Proc Inst Mech Eng"},{"key":"e_1_2_8_44_2","first-page":"3","article-title":"Neutral proteinases and their inhibitors in the loosening of total hip prostheses","volume":"271","author":"Takagi M","year":"1996","journal-title":"Acta Orthop Scand Suppl"},{"key":"e_1_2_8_45_2","doi-asserted-by":"publisher","DOI":"10.1359\/jbmr.2001.16.10.1780"},{"key":"e_1_2_8_46_2","doi-asserted-by":"publisher","DOI":"10.1002\/art.22064"},{"key":"e_1_2_8_47_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-199306000-00007"},{"key":"e_1_2_8_48_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.81B1.8884"},{"key":"e_1_2_8_49_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(05)80080-4"},{"key":"e_1_2_8_50_2","doi-asserted-by":"crossref","first-page":"1081","DOI":"10.2106\/00004623-200705000-00022","article-title":"Assessing osteolysis with use of high\u2010throughput protein chips","volume":"89","author":"Shanbhag AS","year":"2007","journal-title":"J Bone Joint Surg Am"},{"key":"e_1_2_8_51_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199807000-00004"},{"key":"e_1_2_8_52_2","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.95.7.3597"},{"key":"e_1_2_8_53_2","doi-asserted-by":"publisher","DOI":"10.1515\/CCLM.2006.117"},{"key":"e_1_2_8_54_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.ATV.0000229218.97976.43"},{"key":"e_1_2_8_55_2","doi-asserted-by":"crossref","first-page":"758","DOI":"10.1302\/0301-620X.85B5.13729","article-title":"Immunological changes in patients with primary osteoarthritis of the hip after total joint replacement","volume":"85","author":"Granchi D","year":"2003","journal-title":"J Bone Joint Surg Br"},{"key":"e_1_2_8_56_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.A.02039pp"},{"key":"e_1_2_8_57_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00018-003-3020-0"},{"key":"e_1_2_8_58_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0142-9612(97)00160-9"},{"key":"e_1_2_8_59_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.D.02111"},{"key":"e_1_2_8_60_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2005.07.019"},{"key":"e_1_2_8_61_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200404000-00025"},{"key":"e_1_2_8_62_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.D.01915"},{"key":"e_1_2_8_63_2","doi-asserted-by":"publisher","DOI":"10.1080\/17453670610012890"},{"key":"e_1_2_8_64_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.b.30454"},{"key":"e_1_2_8_65_2","unstructured":"YauSS WangA EssnerA ManleyM DumbletonJ.Sequential irradiation and annealing of highly crosslinked polyethylenes: Resist oxidation without sacrificing physical\/mechanical properties In Transactions of the 51st Annual Meeting of the Orthopaedic Research Society Washington DC 2005. p1670."},{"key":"e_1_2_8_66_2","first-page":"151","volume-title":"Crosslinked and Thermally Treated Ultra\u2010High Molecular Weight Polyethylene for Joint Replacements, ASTM STP1445","author":"Wang A","year":"2003"},{"key":"e_1_2_8_67_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2007.08.025"},{"key":"e_1_2_8_68_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2005.04.026"},{"key":"e_1_2_8_69_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.a.10133"},{"key":"e_1_2_8_70_2","first-page":"944","article-title":"Surface grafting of artificial joints with a biocompatible polymer for preventing periprosthetic osteolysis","volume":"18","author":"Moro T","year":"2004","journal-title":"Nat Mater"},{"key":"e_1_2_8_71_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.a.31134"},{"key":"e_1_2_8_72_2","first-page":"229","article-title":"Arthroplastie totale de la hanche par proth\u00e8se en alumine frit\u00e9e","volume":"58","author":"Boutin PM","year":"1972","journal-title":"Rev Chir Orthop"},{"key":"e_1_2_8_73_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200201000-00011"},{"key":"e_1_2_8_74_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.81B3.8737"},{"key":"e_1_2_8_75_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.79B1.6621"},{"key":"e_1_2_8_76_2","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1097\/00003086-199209000-00005","article-title":"On the material and the tribology of alumina\u2010alumina couplings for hip joint prostheses","volume":"282","author":"Walter A","year":"1992","journal-title":"Clin Orthop Relat Res"},{"key":"e_1_2_8_77_2","doi-asserted-by":"publisher","DOI":"10.1016\/0142-9612(96)00042-7"},{"key":"e_1_2_8_78_2","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1097\/01.blo.0000096806.78689.50","article-title":"Fractures of ceramic bearings: History and present status","volume":"417","author":"Hannouche D","year":"2003","journal-title":"Clin Orthop Relat Res"},{"key":"e_1_2_8_79_2","first-page":"263","article-title":"Wear properties of alumina\/zirconia composite ceramics for joint prostheses measured with an end\u2010face apparatus","volume":"14","author":"Morita Y","year":"2004","journal-title":"Biomed Mater Eng"},{"key":"e_1_2_8_80_2","first-page":"1","volume-title":"Biomaterials. Principles and Applications","author":"Park JB","year":"2003"},{"key":"e_1_2_8_81_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.blo.0000150451.50452.da"},{"key":"e_1_2_8_82_2","volume-title":"Pitting corrosion of metals","author":"Zskalaska\u2010Smialowska Z","year":"1986"},{"key":"e_1_2_8_83_2","doi-asserted-by":"publisher","DOI":"10.1002\/jab.770060104"},{"key":"e_1_2_8_84_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0142-9612(98)00229-4"},{"key":"e_1_2_8_85_2","doi-asserted-by":"crossref","first-page":"2168","DOI":"10.2106\/00004623-200311000-00017","article-title":"Serum cobalt levels after metal on metal total hip arthroplasty","volume":"85","author":"Brodner W","year":"2003","journal-title":"J Bone Joint Surg A"},{"key":"e_1_2_8_86_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0736-0266(02)00152-3"},{"key":"e_1_2_8_87_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2003.12.076"},{"key":"e_1_2_8_88_2","doi-asserted-by":"publisher","DOI":"10.1055\/s-2008-1039623"},{"key":"e_1_2_8_89_2","doi-asserted-by":"crossref","first-page":"512","DOI":"10.2106\/00004623-199072040-00007","article-title":"In vivo wear of titanium alloy hip prostheses","volume":"72","author":"McKellop HA","year":"1990","journal-title":"J Bone Joint Surg A"},{"key":"e_1_2_8_90_2","first-page":"7376","article-title":"In vivo tribological performance of 231metal\u2010on\u2010metal hip articulation bearings","volume":"12","author":"Riecker CB","year":"2002","journal-title":"Hip Int"},{"key":"e_1_2_8_91_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(04)00516-9"},{"key":"e_1_2_8_92_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.D.02641"},{"key":"e_1_2_8_93_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.orthres.2004.12.007"},{"key":"e_1_2_8_94_2","first-page":"143","article-title":"Quantitative analysis of wear and wear debris from metal\u2010on\u2010metal hip prosthesis tested in a physiological hip joint stimulator","volume":"11","author":"Firkins PJ","year":"2001","journal-title":"Biomed Mater Eng"},{"key":"e_1_2_8_95_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.b.10053"},{"key":"e_1_2_8_96_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.blo.0000150309.48474.8b"},{"key":"e_1_2_8_97_2","first-page":"16","article-title":"Legenstein","volume":"5","author":"B\u00f6sch P","year":"2004","journal-title":"Plus and minus der metal\u2010metall\u2010paarung Orthop\u00e4die"},{"key":"e_1_2_8_98_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.89B3.18520"},{"key":"e_1_2_8_99_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200103000-00017"},{"key":"e_1_2_8_100_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.E.00604"},{"key":"e_1_2_8_101_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.a.10540"},{"key":"e_1_2_8_102_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200200002-00002"},{"key":"e_1_2_8_103_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.84B3.12261"},{"key":"e_1_2_8_104_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.89B7.18981"},{"key":"e_1_2_8_105_2","doi-asserted-by":"publisher","DOI":"10.1054\/arth.2002.30292"},{"key":"e_1_2_8_106_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199807000-00014"},{"key":"e_1_2_8_107_2","first-page":"67","article-title":"Studies on host response to orthopaedic implants and biomaterials","volume":"9","author":"Santavirta S","year":"1999","journal-title":"J Long\u2010Term Eff Med Implants"}],"container-title":["Journal of Biomedical Materials Research Part A"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fjbm.a.32063","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jbm.a.32063","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,13]],"date-time":"2023-10-13T01:13:54Z","timestamp":1697159634000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jbm.a.32063"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,5,28]]},"references-count":106,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2009,8]]}},"alternative-id":["10.1002\/jbm.a.32063"],"URL":"https:\/\/doi.org\/10.1002\/jbm.a.32063","archive":["Portico"],"relation":{},"ISSN":["1549-3296","1552-4965"],"issn-type":[{"value":"1549-3296","type":"print"},{"value":"1552-4965","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,5,28]]}}}