{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T00:12:55Z","timestamp":1782951175199,"version":"3.54.5"},"reference-count":35,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2005,7,13]],"date-time":"2005-07-13T00:00:00Z","timestamp":1121212800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Biomed Mater Res"],"published-print":{"date-parts":[[2005,10]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Recently, a new degradable polymer has been developed on the basis of alkylene bis(dilactoyl)\u2010methacrylate as an alternative material for screw augmentation. The polymer has been investigated <jats:italic>in vitro<\/jats:italic> and in a short\u2010term experiment in rabbits exhibiting promising results. The aim of the present study was to investigate its long\u2010term biocompatibility and mechanical functionality in a large animal model. The polymer was used for screw augmentation in the cancellous bone of the femoral condyle and tibia epiphysis of 12 sheep and was compared to polymethylmethacrylate (PMMA) augmented and nonaugmented screws. After an implantation period of 6 months, bone, regional lymph nodes, and several organs were histologically evaluated. The mechanical efficacy was investigated by a biomechanical pullout test. A lot of mononuclear macrophages and multinuclear foreign body giant cells with incorporated polymer particles indicate strong inflammatory reactions. Large osteolysis zones with osteoclasts were found in the surrounding polymer. The polymer was fragmented but not substantially degraded. Polymer particles were also found in the regional lymph nodes. Lung, liver, kidney, and spleen did not show any pathological signs. The pullout force of screws augmented with the new polymer was significantly reduced in comparison to PMMA augmented and nonaugmented screws, respectively. It was concluded that the material has poor biocompatibility and cannot be recommended for clinical application as screw augmentation material. \u00a9 2005 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2005<\/jats:p>","DOI":"10.1002\/jbm.b.30274","type":"journal-article","created":{"date-parts":[[2005,7,13]],"date-time":"2005-07-13T22:46:31Z","timestamp":1121294791000},"page":"128-136","source":"Crossref","is-referenced-by-count":11,"title":["Biocompatibility and functionality of the degradable polymer alkylene bis(dilactoyl)\u2010methacrylate for screw augmentation <i>in vivo<\/i>"],"prefix":"10.1002","volume":"75B","author":[{"given":"Anita A.","family":"Ignatius","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Augat","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elke","family":"Hollstein","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sandra","family":"Schorlemmer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manfred","family":"Peraus","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Pokinskyj","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lutz","family":"Claes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2005,7,13]]},"reference":[{"key":"e_1_2_7_2_2","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1097\/00003086-199211000-00036","article-title":"Holding power and reinforcement of cancellous screws in human bone","volume":"284","author":"Kleeman BC","year":"1992","journal-title":"Clin Orthop"},{"key":"e_1_2_7_3_2","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-199708010-00003"},{"key":"e_1_2_7_4_2","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-199402000-00017"},{"key":"e_1_2_7_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0142-9612(97)00118-X"},{"key":"e_1_2_7_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/S8756-3282(99)00127-1"},{"key":"e_1_2_7_7_2","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1097\/00003086-199310000-00035","article-title":"Thermal aspects of the use of polymethylmethacrylate in large metaphyseal defects in bone. A clinical review and laboratory study","volume":"295","author":"Leeson MC","year":"1993","journal-title":"Clin Orthop"},{"key":"e_1_2_7_8_2","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1007\/s00068-001-1122-7","article-title":"Screw fixation in cancellous osteoporotic bone\u2014First in vitro results with a novel augmentation material","volume":"5","author":"Kock HJ","year":"2001","journal-title":"Eur J Trauma"},{"key":"e_1_2_7_9_2","doi-asserted-by":"publisher","DOI":"10.1002\/1097-4636(2001)58:3<329::AID-JBM1025>3.0.CO;2-9"},{"key":"e_1_2_7_10_2","doi-asserted-by":"publisher","DOI":"10.1243\/0954411981534196"},{"key":"e_1_2_7_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/S8756-3282(99)00142-8"},{"key":"e_1_2_7_12_2","first-page":"2","article-title":"Resorbable calcium phosphate cement augmentation of pedicle screw fixation in the human lumbar spine","volume":"4","author":"Shao JF","year":"2000","journal-title":"Hong Kong J Orthopaed Surg"},{"key":"e_1_2_7_13_2","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1097\/00003086-199203000-00017","article-title":"Ceramics in orthopedic surgery","volume":"276","author":"Cooke FW","year":"1992","journal-title":"Clin Orthop"},{"key":"e_1_2_7_14_2","doi-asserted-by":"publisher","DOI":"10.1002\/1097-4636(2001)58:3<254::AID-JBM1014>3.0.CO;2-A"},{"key":"e_1_2_7_15_2","first-page":"132","volume-title":"Biomaterials in surgery","author":"Wenz R","year":"1998"},{"key":"e_1_2_7_16_2","unstructured":"RitterW. Eur. Pat. Appl. 0086 401 (1989)."},{"key":"e_1_2_7_17_2","doi-asserted-by":"publisher","DOI":"10.1515\/BMT.2004.031"},{"key":"e_1_2_7_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2004.04.048"},{"key":"e_1_2_7_19_2","doi-asserted-by":"crossref","unstructured":"HeissC SchnettlerR.Bioresorbierbare Klebstoffe in der operativen Traumatologie und Orthop\u00e4die Biomater2003;4:298\u2013304.","DOI":"10.1515\/BIOMAT.2003.4.4.298"},{"key":"e_1_2_7_20_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.a.10601"},{"key":"e_1_2_7_21_2","doi-asserted-by":"publisher","DOI":"10.1359\/jbmr.2003.18.11.2010"},{"key":"e_1_2_7_22_2","first-page":"63","article-title":"Neue resorbierbare Polymere f\u00fcr die Schrauben\u2010Augmentation: Abbauverhalten und mechanische Eigenschaften","volume":"10","author":"Pokinskyj P","year":"2001","journal-title":"Osteologie"},{"key":"e_1_2_7_23_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-199274070-00008"},{"key":"e_1_2_7_24_2","doi-asserted-by":"publisher","DOI":"10.1023\/B:ABME.0000007802.59936.fc"},{"key":"e_1_2_7_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/0142-9612(96)81421-9"},{"key":"e_1_2_7_26_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.820271214"},{"key":"e_1_2_7_27_2","doi-asserted-by":"publisher","DOI":"10.1002\/jab.770040103"},{"key":"e_1_2_7_28_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.820290407"},{"key":"e_1_2_7_29_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.79B6.7832"},{"key":"e_1_2_7_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0142-9612(03)00317-X"},{"key":"e_1_2_7_31_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-4636(199607)31:3<319::AID-JBM5>3.0.CO;2-P"},{"key":"e_1_2_7_32_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00423-002-0306-x"},{"key":"e_1_2_7_33_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-4636(199722)38:2<155::AID-JBM10>3.0.CO;2-C"},{"key":"e_1_2_7_34_2","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1097\/00003086-199311000-00045","article-title":"Effect of screw diameter, insertion technique, and bone cement augmentation of pedicular screw fixation strength","volume":"296","author":"Wittenberg RH","year":"1993","journal-title":"Clin Orthop"},{"key":"e_1_2_7_35_2","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-199111000-00015"},{"key":"e_1_2_7_36_2","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1097\/00003086-198602000-00012","article-title":"A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine","volume":"203","author":"Zindrick MR","year":"1986","journal-title":"Clin Orthop"}],"container-title":["Journal of Biomedical Materials Research Part B: Applied Biomaterials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fjbm.b.30274","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jbm.b.30274","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,12]],"date-time":"2023-10-12T14:51:03Z","timestamp":1697122263000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jbm.b.30274"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,7,13]]},"references-count":35,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2005,10]]}},"alternative-id":["10.1002\/jbm.b.30274"],"URL":"https:\/\/doi.org\/10.1002\/jbm.b.30274","archive":["Portico"],"relation":{},"ISSN":["1552-4973","1552-4981"],"issn-type":[{"value":"1552-4973","type":"print"},{"value":"1552-4981","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,7,13]]}}}