{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,10,9]],"date-time":"2023-10-09T05:11:43Z","timestamp":1696828303486},"reference-count":42,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2011,5,11]],"date-time":"2011-05-11T00:00:00Z","timestamp":1305072000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Biomed Mater Res"],"published-print":{"date-parts":[[2011,7]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Inflammatory bowel diseases, cancer or trauma may require removal of all or part of the intestines, leaving the patient with a need to wear external stoma appliances for collection of bowel contents. By connecting the small bowel to a percutaneous port, equipped with a sealing lid, a fully continent and leak proof stoma can be created without a need for permanently wearing stoma appliance. The prerequisites for a connection between a permanent, transabdominal implant and a visceral organ are largely unexplored. Stoma ports made of titanium were implanted in the abdominal wall of domestic pigs and a branch of distal ileum was inserted through the ports. After being followed for 1\u20133 weeks, the ports were removed and subjected to histological evaluation to study the influence of their shape, structure, and position on the tissue response. Particular focus was attended to the attachment of the ileal serosal surface to the implants inner structure consisting of a titanium mesh. Macroscopic examination revealed fistulas and formation of abscesses in 4 of 11 the retrieved implants. Histological examination revealed regenerated and well\u2010vascularized collagenous tissue around the mesh structure inside the implant. The integration was complete or partial for 10 of 11 ports. Despite various degrees of inflammation and tissue ingrowth, it was demonstrated for the first time that the serosal surface of ileum was firmly attached to the internal structure of the implant. These experiments provide a basis for optimization of the implant and surgical procedure before long\u2010term functional animal experiments. \u00a9 2011 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2011.<\/jats:p>","DOI":"10.1002\/jbm.b.31838","type":"journal-article","created":{"date-parts":[[2011,5,11]],"date-time":"2011-05-11T16:31:48Z","timestamp":1305131508000},"page":"101-109","source":"Crossref","is-referenced-by-count":2,"title":["Integration between a percutaneous implant and the porcine small bowel"],"prefix":"10.1002","volume":"98B","author":[{"given":"Martin L.","family":"Johansson","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter","family":"Thomsen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Leif","family":"Hult\u00e9n","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Per Steinar","family":"Halvorsen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Erik","family":"Fosse","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bj\u00f8rn","family":"Edwin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2011,5,11]]},"reference":[{"key":"e_1_2_5_2_2","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e318187e186"},{"key":"e_1_2_5_3_2","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1177\/014556139407300210","article-title":"Long\u2010term follow\u2010up with the bone\u2010anchored hearing aid: A review of the first 100 patients between 1977 and 1985","volume":"73","author":"Tjellstrom A","year":"1994","journal-title":"Ear Nose Throat J"},{"key":"e_1_2_5_4_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.a.31074"},{"key":"e_1_2_5_5_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00270-004-6500-1"},{"key":"e_1_2_5_6_2","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1177\/089686080102100305","article-title":"A new titanium fiber mesh\u2010cuffed peritoneal dialysis catheter: Evaluation and comparison with a dacron\u2010cuffed tenckhoff catheter in goats","volume":"21","author":"Walboomers F","year":"2001","journal-title":"Perit Dial Int"},{"key":"e_1_2_5_7_2","doi-asserted-by":"publisher","DOI":"10.3109\/08941939609012462"},{"key":"e_1_2_5_8_2","doi-asserted-by":"publisher","DOI":"10.3109\/08941938909016501"},{"key":"e_1_2_5_9_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1464-5491.1991.tb01663.x"},{"key":"e_1_2_5_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvir.2008.11.029"},{"key":"e_1_2_5_11_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2516.2003.00724.x"},{"key":"e_1_2_5_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2007.03.085"},{"key":"e_1_2_5_13_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11255-004-1562-1"},{"key":"e_1_2_5_14_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.820180403"},{"key":"e_1_2_5_15_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.820180405"},{"key":"e_1_2_5_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0142-9612(02)00134-5"},{"key":"e_1_2_5_17_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1440-1843.2002.00404.x"},{"key":"e_1_2_5_18_2","first-page":"1","article-title":"Structure and function of mesothelial cells","volume":"134","author":"Mutsaers SE","year":"2007","journal-title":"Cancer Treat Res"},{"key":"e_1_2_5_19_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0714.1982.tb00172.x"},{"key":"e_1_2_5_20_2","first-page":"336","article-title":"Achieving ileostomy continence with an indwelling stomal device","volume":"90","author":"Pemberton JH","year":"1981","journal-title":"Surgery"},{"key":"e_1_2_5_21_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000658-198305000-00016"},{"key":"e_1_2_5_22_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF02586768"},{"key":"e_1_2_5_23_2","doi-asserted-by":"publisher","DOI":"10.1002\/bjs.1800640715"},{"key":"e_1_2_5_24_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF02603415"},{"key":"e_1_2_5_25_2","first-page":"194","article-title":"Animal studies on the construction of continent ileostomies and colostomies with the use of BioCarbon implants","author":"Bustamante I","year":"1977","journal-title":"Chir Forum Exp Klin Forsch"},{"key":"e_1_2_5_26_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1464-410X.1978.tb06196.x"},{"key":"e_1_2_5_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/0090-4295(89)90149-0"},{"key":"e_1_2_5_28_2","doi-asserted-by":"publisher","DOI":"10.3109\/00365599609182349"},{"key":"e_1_2_5_29_2","doi-asserted-by":"publisher","DOI":"10.1002\/jab.770040210"},{"key":"e_1_2_5_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/0267-6605(91)90061-J"},{"key":"e_1_2_5_31_2","doi-asserted-by":"publisher","DOI":"10.1016\/0142-9612(96)84946-5"},{"key":"e_1_2_5_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0039-6060(96)80196-6"},{"key":"e_1_2_5_33_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.surg.2006.01.020"},{"key":"e_1_2_5_34_2","first-page":"315","article-title":"Stable formation of the nipple valve in Kock pouch for diversion of the urinary tract","volume":"169","author":"Okada Y","year":"1989","journal-title":"Surg Gynecol Obstet"},{"key":"e_1_2_5_35_2","first-page":"63","article-title":"Continent ileostomy. The present technique and long term results","volume":"75","author":"Kock NG","year":"1986","journal-title":"Ann Chir Gynaecol"},{"key":"e_1_2_5_36_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1463-1318.2007.01264.x"},{"key":"e_1_2_5_37_2","doi-asserted-by":"publisher","DOI":"10.1097\/MAT.0b013e3181d034f6"},{"key":"e_1_2_5_38_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.820250310"},{"key":"e_1_2_5_39_2","doi-asserted-by":"publisher","DOI":"10.1016\/0142-9612(95)98267-I"},{"key":"e_1_2_5_40_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-4636(19990915)46:4<458::AID-JBM3>3.0.CO;2-I"},{"key":"e_1_2_5_41_2","doi-asserted-by":"publisher","DOI":"10.1002\/term.4"},{"key":"e_1_2_5_42_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.burns.2004.01.018"},{"key":"e_1_2_5_43_2","doi-asserted-by":"publisher","DOI":"10.1016\/0031-6865(94)00050-6"}],"container-title":["Journal of Biomedical Materials Research Part B: Applied Biomaterials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fjbm.b.31838","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jbm.b.31838","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,8]],"date-time":"2023-10-08T20:11:51Z","timestamp":1696795911000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jbm.b.31838"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,5,11]]},"references-count":42,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2011,7]]}},"alternative-id":["10.1002\/jbm.b.31838"],"URL":"https:\/\/doi.org\/10.1002\/jbm.b.31838","archive":["Portico"],"relation":{},"ISSN":["1552-4973","1552-4981"],"issn-type":[{"value":"1552-4973","type":"print"},{"value":"1552-4981","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,5,11]]}}}