{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,12]],"date-time":"2026-02-12T08:06:16Z","timestamp":1770883576180,"version":"3.50.1"},"reference-count":23,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2011,7,5]],"date-time":"2011-07-05T00:00:00Z","timestamp":1309824000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Biomed Mater Res"],"published-print":{"date-parts":[[2011,10]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Electrospinning using synthetic and natural polymers is a promising technique for the fabrication of scaffolds for tissue engineering. Numerous synthetic polymers are available to maximize durability and mechanical properties (polyurethane) versus degradability and cell adhesion (polycaprolactone). In this study, we explored the feasibility of creating scaffolds made of bicomponent nanofibers from both polymers using a coaxial electrospinning system. We used a core of poly(urethane) and a sheath of a mixture of poly(\u03b5\u2010caprolactone) and gelatin, all dissolved in 1,1,1,3,3,3\u2010hexafluror\u20102\u2010propanol. These nanofibrous scaffolds were then evaluated to confirm their core\u2013sheath nature and characterize their morphology and mechanical properties under static and dynamic conditions. Furthermore, the antigenicity of the scaffolds was studied to confirm that there is no significant foreign body response to the scaffold itself that would preclude its use <jats:italic>in vivo<\/jats:italic>. The results show the advantages of combining both natural and synethic polymers to create a coaxial scaffold capable of withstanding dynamic culture conditions and encourage cellular migration to the interior of the scaffold for tissue\u2010engineering applications. Also, the results show that there is no significant immunoreactivity <jats:italic>in vivo<\/jats:italic> to the components of the scaffolds. \u00a9 2011 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2011.<\/jats:p>","DOI":"10.1002\/jbm.b.31885","type":"journal-article","created":{"date-parts":[[2011,7,5]],"date-time":"2011-07-05T19:30:37Z","timestamp":1309894237000},"page":"180-190","source":"Crossref","is-referenced-by-count":32,"title":["Hybrid coaxial electrospun nanofibrous scaffolds with limited immunological response created for tissue engineering"],"prefix":"10.1002","volume":"99B","author":[{"given":"Jessica M.","family":"Gluck","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paymon","family":"Rahgozar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nilesh P.","family":"Ingle","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fironia","family":"Rofail","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Asdghig","family":"Petrosian","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael G.","family":"Cline","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maria C.","family":"Jordan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kenneth P.","family":"Roos","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"William Robb","family":"MacLellan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Richard J.","family":"Shemin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sepideh","family":"Heydarkhan\u2010Hagvall","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2011,7,5]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1126\/science.8493529"},{"issue":"1","key":"e_1_2_6_3_2","first-page":"S132","article-title":"Tissue engineering: The design and fabrication of living replacement devices for surgical reconstruction and transplantation","volume":"354","author":"Vacanti JP","year":"1999","journal-title":"Lancet"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1243\/0954411001535273"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1369-7021(04)00233-0"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0142-9612(02)00562-8"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-94-017-1217-0_10"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1007\/0-306-47583-9_4"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2004.10.018"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.b.30122"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.10167"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.2741\/1313"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.polymer.2004.01.024"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.addr.2007.04.021"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2008.03.034"},{"key":"e_1_2_6_16_2","unstructured":"1987 Wiley New York P Rose Encyclopedia of polymer science and engineering"},{"key":"e_1_2_6_17_2","volume-title":"The science and technology of gelatin","author":"Johns P","year":"1977"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.smim.2007.11.004"},{"key":"e_1_2_6_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0168-3659(01)00502-8"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1146\/annurev.matsci.31.1.81"},{"key":"e_1_2_6_21_2","doi-asserted-by":"publisher","DOI":"10.1163\/156856295X00698"},{"key":"e_1_2_6_22_2","doi-asserted-by":"publisher","DOI":"10.3109\/08941938909016503"},{"key":"e_1_2_6_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/0142-9612(92)90121-4"},{"key":"e_1_2_6_24_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.820060505"}],"container-title":["Journal of Biomedical Materials Research Part B: Applied Biomaterials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fjbm.b.31885","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jbm.b.31885","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,16]],"date-time":"2023-10-16T16:47:25Z","timestamp":1697474845000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jbm.b.31885"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,7,5]]},"references-count":23,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2011,10]]}},"alternative-id":["10.1002\/jbm.b.31885"],"URL":"https:\/\/doi.org\/10.1002\/jbm.b.31885","archive":["Portico"],"relation":{},"ISSN":["1552-4973","1552-4981"],"issn-type":[{"value":"1552-4973","type":"print"},{"value":"1552-4981","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,7,5]]}}}