{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T23:02:12Z","timestamp":1790982132384,"version":"4.1.0"},"reference-count":50,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2012,3,27]],"date-time":"2012-03-27T00:00:00Z","timestamp":1332806400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Biomed Mater Res"],"published-print":{"date-parts":[[2012,8]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Total hip replacement has been a successful surgical intervention for over 50 years, with the majority of bearings using a polyethylene cup. Long\u2010term failure due to osteolysis and loosening has been widely documented and alternative bearings have been sought. A novel carbon fiber\u2010reinforced poly\u2010ether ether ketone (CFR\u2010PEEK) cup was investigated through experimental friction and wear studies. Friction studies demonstrated the bearings operated in a boundary lubrication condition, with friction factors higher than those for other hip replacement bearings. The wear study was conducted with 36 mm diameter bearings tested against Biolox Delta heads for a period of 10 million cycles. The mean volumetric wear rate was 0.3 mm<jats:sup>3<\/jats:sup>\/Mc, indicating the ceramic\u2010on\u2010CFR\u2010PEEK bearing to be a very low wearing option for total hip replacement. \u00a9 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 100B: 1459\u20131465, 2012.<\/jats:p>","DOI":"10.1002\/jbm.b.32664","type":"journal-article","created":{"date-parts":[[2012,3,27]],"date-time":"2012-03-27T19:03:53Z","timestamp":1332875033000},"page":"1459-1465","source":"Crossref","is-referenced-by-count":71,"title":["Wear of ceramic\u2010on\u2010carbon fiber\u2010reinforced poly\u2010ether ether ketone hip replacements"],"prefix":"10.1002","volume":"100B","author":[{"given":"Claire L.","family":"Brockett","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gemma","family":"John","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sophie","family":"Williams","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhongmin","family":"Jin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Graham H.","family":"Isaac","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Fisher","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2012,3,27]]},"reference":[{"key":"e_1_2_7_2_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200200002-00002"},{"key":"e_1_2_7_3_2","first-page":"230","article-title":"Problems with wear in artificial orthopaedic joint replacements: A review","author":"Bolton JD","year":"2002","journal-title":"Key Eng Mater"},{"key":"e_1_2_7_4_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200012000-00004"},{"key":"e_1_2_7_5_2","doi-asserted-by":"publisher","DOI":"10.1243\/0954411001535219"},{"key":"e_1_2_7_6_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.G.00043"},{"key":"e_1_2_7_7_2","first-page":"578","article-title":"Metal\u2010on\u2010metal bearing in hip prosthesis generates 100\u2010fold less wear debris than metal\u2010on\u2010polyethylene","volume":"1999","author":"Anissian HL","journal-title":"Acta Orthop Scand"},{"key":"e_1_2_7_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0142-9612(00)00361-6"},{"key":"e_1_2_7_9_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.91B9.22306"},{"key":"e_1_2_7_10_2","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1097\/BLO.0b013e31814da946","article-title":"The 2007 Otto Aufranc Award: Ceramic\u2010on\u2010metal hip arthroplasties: A comparative in vitro and in vivo study","volume":"465","author":"Williams S","year":"2007","journal-title":"Clin Orthop Relat Res"},{"key":"e_1_2_7_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2004.07.070"},{"key":"e_1_2_7_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.wear.2005.02.035"},{"key":"e_1_2_7_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2006.12.117"},{"key":"e_1_2_7_14_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-010-1556-5"},{"key":"e_1_2_7_15_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.F.00758"},{"key":"e_1_2_7_16_2","doi-asserted-by":"publisher","DOI":"10.1243\/0954411001535228"},{"key":"e_1_2_7_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2004.04.035"},{"key":"e_1_2_7_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.esas.2009.11.006"},{"key":"e_1_2_7_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2009.11.007"},{"key":"e_1_2_7_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.matdes.2005.05.018"},{"key":"e_1_2_7_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2009.11.019"},{"key":"e_1_2_7_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0021-9290(08)70006-X"},{"key":"e_1_2_7_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2008.08.015"},{"issue":"1168","key":"e_1_2_7_24_2","first-page":"e1","article-title":"A painful metal\u2010on\u2010metal total hip arthroplasty: A diagnostic dilemma","volume":"25","author":"Blumenfeld TJ","year":"2010","journal-title":"J Arthroplasty"},{"key":"e_1_2_7_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2010.05.030"},{"key":"e_1_2_7_26_2","unstructured":"CurrierJH ReinitzSD CurrierBH Van CittersDW. Ceramic squeaking: Retrieved hips and never implanted components show ceramic components alone emit the squeaking documented in vivo. In: Proceedings of the Orthopaedic Research Society Las Vegas USA 2010. Paper 161."},{"key":"e_1_2_7_27_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-008-0177-8"},{"key":"e_1_2_7_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2006.06.018"},{"key":"e_1_2_7_29_2","doi-asserted-by":"publisher","DOI":"10.4028\/www.scientific.net\/KEM.240-242.849"},{"key":"e_1_2_7_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2007.07.013"},{"key":"e_1_2_7_31_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0301-679X(98)00088-7"},{"key":"e_1_2_7_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.wear.2009.08.023"},{"key":"e_1_2_7_33_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10856-008-3558-3"},{"key":"e_1_2_7_34_2","doi-asserted-by":"publisher","DOI":"10.1243\/09544119JEIM334"},{"key":"e_1_2_7_35_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2010.04.003"},{"key":"e_1_2_7_36_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.esas.2009.11.004"},{"key":"e_1_2_7_37_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.b.30691"},{"key":"e_1_2_7_38_2","doi-asserted-by":"publisher","DOI":"10.1243\/0954411991535068"},{"key":"e_1_2_7_39_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0043-1648(00)00377-X"},{"key":"e_1_2_7_40_2","doi-asserted-by":"publisher","DOI":"10.1243\/09544119JEIM733"},{"key":"e_1_2_7_41_2","doi-asserted-by":"publisher","DOI":"10.1243\/09544119JEIM21"},{"key":"e_1_2_7_42_2","doi-asserted-by":"publisher","DOI":"10.1243\/0954411011535939"},{"key":"e_1_2_7_43_2","unstructured":"BrockettCL WilliamsS IsaacGH FisherJ. Effect of third body particles on the tribology and surface finish of COM MOM and COC bearings. 55th Annual Meeting of the Orthopaedic Research Society Las Vegas;2009."},{"key":"e_1_2_7_44_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0043-1648(01)00741-4"},{"key":"e_1_2_7_45_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0021-9290(00)00188-3"},{"key":"e_1_2_7_46_2","doi-asserted-by":"publisher","DOI":"10.1615\/JLongTermEffMedImplants.v21.i1.40"},{"key":"e_1_2_7_47_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-199604000-00004"},{"key":"e_1_2_7_48_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0043-1648(03)00167-4"},{"key":"e_1_2_7_49_2","doi-asserted-by":"publisher","DOI":"10.1016\/0142-9612(85)90007-9"},{"key":"e_1_2_7_50_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.b.10068"},{"key":"e_1_2_7_51_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2010.06.002"}],"container-title":["Journal of Biomedical Materials Research Part B: Applied Biomaterials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fjbm.b.32664","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jbm.b.32664","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,10]],"date-time":"2023-10-10T04:25:57Z","timestamp":1696911957000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jbm.b.32664"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,3,27]]},"references-count":50,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2012,8]]}},"alternative-id":["10.1002\/jbm.b.32664"],"URL":"https:\/\/doi.org\/10.1002\/jbm.b.32664","archive":["Portico"],"relation":{},"ISSN":["1552-4973","1552-4981"],"issn-type":[{"value":"1552-4973","type":"print"},{"value":"1552-4981","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,3,27]]}}}