{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,6]],"date-time":"2026-02-06T22:03:53Z","timestamp":1770415433341,"version":"3.49.0"},"reference-count":32,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2015,2,10]],"date-time":"2015-02-10T00:00:00Z","timestamp":1423526400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"name":"Institute for Advancing Medical Innovation"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Biomed Mater Res"],"published-print":{"date-parts":[[2016,1]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Spinal fusion surgeries have a high failure rate for difficult\u2010to\u2010fuse patients. A piezoelectric spinal fusion implant was developed to overcome the issues with other adjunct therapies. Stacked generators were used to improve power generation at low electrical load resistances. The effects of the number of layers on average maximum power and the optimal electrical load resistance were characterized. The effects of mechanical preload, load frequency, and amplitude on maximum power and optimal electrical load resistance were also characterized. Increasing the number of layers from one to nine was found to lower the optimal electrical load resistance from 1.00 G\u03a9 to 16.78 M\u03a9 while maintaining maximum power generation. Mechanical preload did not have a significant effect on power output or optimal electrical load resistance. Increases in mechanical loading frequency increased average maximum power, while decreasing the optimal electrical load resistance. Increases in mechanical loading amplitude increased average maximum power output without affecting the optimal electrical load resistance. \u00a9 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 158\u2013164, 2016.<\/jats:p>","DOI":"10.1002\/jbm.b.33365","type":"journal-article","created":{"date-parts":[[2015,2,12]],"date-time":"2015-02-12T18:08:02Z","timestamp":1423764482000},"page":"158-164","source":"Crossref","is-referenced-by-count":9,"title":["Composite piezoelectric spinal fusion implant: Effects of stacked generators"],"prefix":"10.1002","volume":"104","author":[{"given":"Nathan C.","family":"Goetzinger","sequence":"first","affiliation":[{"name":"Bioengineering Graduate Program University of Kansas Lawrence Kansas 66045"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eric J.","family":"Tobaben","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering University of Kansas Lawrence Kansas 66045"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John P.","family":"Domann","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering University of Kansas Lawrence Kansas 66045"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paul M.","family":"Arnold","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery Kansas University Medical Center Kansas City Kansas 66160"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elizabeth A.","family":"Friis","sequence":"additional","affiliation":[{"name":"Bioengineering Graduate Program University of Kansas Lawrence Kansas 66045"},{"name":"Department of Mechanical Engineering University of Kansas Lawrence Kansas 66045"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2015,2,10]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(99)01312-4"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-200010150-00007"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2003.11.005"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-198803000-00026"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-199903010-00012"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-199411000-00004"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.4103\/2152-7806.76147"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.4103\/2152-7806.83929"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2011.04.023"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-199007000-00016"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1529-9430(02)00177-8"},{"key":"e_1_2_7_13_1","first-page":"131","article-title":"Prospective comparison of autograft vs. allograft for adult posterolateral lumbar spine fusion: Differences among freeze\u2010dried, frozen, and mixed grafts","volume":"8","author":"An HS","year":"1995","journal-title":"J Spinal Disord Tech"},{"key":"e_1_2_7_14_1","first-page":"63","article-title":"Electricity: the history and science of bone growth stimulation for spinal fusion","volume":"4","author":"Glazer PA","year":"2002","journal-title":"Orthop J Harvard Med School Online"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.a.34750"},{"key":"e_1_2_7_16_1","unstructured":"Biomet. Implantable spinal fusion simulators physician's manual & full prescribing information SpF PLUS\u2010Mini SpF\u2010XL IIb. Available at:http:\/\/www.biomet.com\/spine\/products.cfm?pdid=3&majcid=61;2014."},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1109\/40.928763"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1109\/TMECH.2005.844704"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.brs.0000221984.12004.3b"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10856-006-0597-5"},{"key":"e_1_2_7_21_1","first-page":"202","volume-title":"Materials and Coatings for Medical Devices: Cardiovascular","author":"ASM International","year":"2009"},{"key":"e_1_2_7_22_1","unstructured":"ET Incorporated. EPO\u2010TEK 301 Technical Data Sheet.2012. Available at:http:\/\/oldwww.epotek.com\/SSCDocs\/datasheets\/301.PDF."},{"key":"e_1_2_7_23_1","unstructured":"QEP Products. Quadrant EPP Ketron 1000 PEEK Polyetheretherketone Unfilled Extruded (ASTM Product Data Sheet). Available at:http:\/\/www.matweb.com\/search\/datasheettext.aspx?matguid=53b9159c018544a599a06726922c9b8e."},{"key":"e_1_2_7_24_1","unstructured":"Smart Materials Corporation 5A1 5H2 Typical Material Properties;2014. Available at:http:\/\/www.smart-material.com\/PZTFiber-product-main.html."},{"key":"e_1_2_7_25_1","unstructured":"SM Corporation. Typical PZT Fiber Ordering and Availability Data.2014. Available at:http:\/\/www.smart-material.com\/PZTFiber-product-main.html"},{"key":"e_1_2_7_26_1","first-page":"36","article-title":"Frequency and velocity of people walking","volume":"83","author":"Pachi A","year":"2005","journal-title":"Struct Eng"},{"key":"e_1_2_7_27_1","doi-asserted-by":"publisher","DOI":"10.1109\/10.184706"},{"key":"e_1_2_7_28_1","doi-asserted-by":"publisher","DOI":"10.1088\/0960-1317\/19\/9\/094006"},{"key":"e_1_2_7_29_1","doi-asserted-by":"publisher","DOI":"10.1088\/0964-1726\/16\/5\/054"},{"key":"e_1_2_7_30_1","doi-asserted-by":"publisher","DOI":"10.1002\/jor.1100070309"},{"key":"e_1_2_7_31_1","first-page":"1435","article-title":"Biochemical compatibility of PZT piezoelectric ceramics covered with titanium thin film","volume":"8","author":"Sakai T","year":"2006","journal-title":"J Optoelectron Adv Mater"},{"key":"e_1_2_7_32_1","doi-asserted-by":"publisher","DOI":"10.1038\/nnano.2012.112"},{"key":"e_1_2_7_33_1","volume-title":"Test Methods For Intervertebral Body Fusion Devices","author":"ASTM F2077\u201011","year":"2011"}],"container-title":["Journal of Biomedical Materials Research Part B: Applied Biomaterials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fjbm.b.33365","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fjbm.b.33365","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jbm.b.33365","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,3]],"date-time":"2023-10-03T23:00:31Z","timestamp":1696374031000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jbm.b.33365"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,2,10]]},"references-count":32,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2016,1]]}},"alternative-id":["10.1002\/jbm.b.33365"],"URL":"https:\/\/doi.org\/10.1002\/jbm.b.33365","archive":["Portico"],"relation":{},"ISSN":["1552-4973","1552-4981"],"issn-type":[{"value":"1552-4973","type":"print"},{"value":"1552-4981","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,2,10]]}}}