{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,8,10]],"date-time":"2024-08-10T17:51:29Z","timestamp":1723312289633},"reference-count":42,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2017,6,21]],"date-time":"2017-06-21T00:00:00Z","timestamp":1498003200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Biomed Mater Res"],"published-print":{"date-parts":[[2018,4]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The articulating components of artificial joints consist mainly of metals, ceramics, or polymers. Resulting abrasive wear particles can promote osteolysis and aseptic loosening of the endo\u2010prosthetic implants. Ultra\u2010high\u2010molecular\u2010weight\u2010polyethylene is the material used most for bearing couples in total hip replacement. In the present study, three types of polyethylene (PE) liners varying in material composition, i.e., (1) conventional PE (C\u2010PE), (2) sequentially cross\u2010linked PE (SX\u2010PE), (3) cross\u2010linked PE blended with vitamin E (EX\u2010PE) articulating with two types of femoral heads were used. After ultrasound treatment of each simulator lubricant, different concentrations (0.1\/0.25\/0.5\/1.0 mL) were taken and dissolved in hydrochloric acid (37%) in a similar manner. The aim was to analyze the characteristics of wear particles generated in a hip simulator, with respect to different volumes of the lubricant. Within the scope of particle analysis, distinct alterations for particle characteristics were determined in the lubricant volumes and types of PE material used. A significant decrease in particle number for SX\u2010PE liners, compared to the C\u2010PE inserts and even more for EX\u2010PE inserts, was detected at each lubricant volume. Particle morphologies varied depending on PE material. Alterations in particle size and other morphologic parameters between the four tested volumes, could be proven for each PE type. In general, particle sizes and parameters (e.g., length and width) increased with increasing serum volumes. In conclusion, the chosen volume of the simulator lubricant used for particle analysis has a crucial influence on detected particle number, size distribution, and morphologic parameters. \u00a9 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1299\u20131306, 2018.<\/jats:p>","DOI":"10.1002\/jbm.b.33944","type":"journal-article","created":{"date-parts":[[2017,6,21]],"date-time":"2017-06-21T14:33:47Z","timestamp":1498055627000},"page":"1299-1306","source":"Crossref","is-referenced-by-count":2,"title":["Influence of analyzed lubricant volumes on the amount and characteristics of generated wear particles from three different types of polyethylene liner materials"],"prefix":"10.1002","volume":"106","author":[{"given":"Jana","family":"Markhoff","sequence":"first","affiliation":[{"name":"Department of Orthopaedics, University Medicine Rostock, Biomechanics and Implant Technology Laboratory Rostock 18057 Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carmen","family":"Zietz","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, University Medicine Rostock, Biomechanics and Implant Technology Laboratory Rostock 18057 Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christian","family":"Fabry","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, University Medicine Rostock, Biomechanics and Implant Technology Laboratory Rostock 18057 Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gerhard","family":"Fulda","sequence":"additional","affiliation":[{"name":"Centre for Electron Microscopy, University Medicine Rostock 18057 Rostock Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rainer","family":"Bader","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, University Medicine Rostock, Biomechanics and Implant Technology Laboratory Rostock 18057 Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2017,6,21]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.5312\/wjo.v2.i10.93"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-010-1161-y"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10856-007-3104-8"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00018-003-3020-0"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2015.08.026"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2014.09.011"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1080\/17453670610045902"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10856-013-4936-z"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1243\/09544119JEIM741"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.b.31416"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.1243\/0954411991534870"},{"key":"e_1_2_8_13_1","doi-asserted-by":"publisher","DOI":"10.1002\/1097-4636(200108)56:2<245::AID-JBM1091>3.0.CO;2-T"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-010-1556-5"},{"key":"e_1_2_8_15_1","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1002\/jbm.b.31257","article-title":"Evaluation of sequentially crosslinked ultra\u2010high molecular weight polyethylene","volume":"90","author":"Morrison ML","year":"2009","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2007.05.007"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2007.06.006"},{"key":"e_1_2_8_18_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10856-006-7309-z"},{"key":"e_1_2_8_19_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-010-1717-6"},{"key":"e_1_2_8_20_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.a.33297"},{"key":"e_1_2_8_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2005.07.009"},{"key":"e_1_2_8_22_1","doi-asserted-by":"publisher","DOI":"10.1243\/0954411021536333"},{"key":"e_1_2_8_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2007.05.043"},{"key":"e_1_2_8_24_1","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200100022-00009"},{"key":"e_1_2_8_25_1","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1002\/jbm.b.31638","article-title":"The relationship of polyethylene wear to particle size, distribution, and number: A possible factor explaining the risk of osteolysis after hip arthroplasty","volume":"94","author":"Gallo J","year":"2010","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"e_1_2_8_26_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-011-2058-9"},{"key":"e_1_2_8_27_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00281-011-0242-3"},{"key":"e_1_2_8_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0142-9612(98)00140-9"},{"key":"e_1_2_8_29_1","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-199509000-00002"},{"key":"e_1_2_8_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0142-9612(00)00195-2"},{"key":"e_1_2_8_31_1","doi-asserted-by":"publisher","DOI":"10.1243\/0954411001535543"},{"key":"e_1_2_8_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/0142-9612(96)83281-9"},{"key":"e_1_2_8_33_1","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.80B2.8234"},{"key":"e_1_2_8_34_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.820290118"},{"key":"e_1_2_8_35_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2013.07.039"},{"key":"e_1_2_8_36_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-011-1334-3"},{"key":"e_1_2_8_37_1","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.L.00432"},{"key":"e_1_2_8_38_1","doi-asserted-by":"publisher","DOI":"10.1186\/1749-799X-8-20"},{"key":"e_1_2_8_39_1","doi-asserted-by":"publisher","DOI":"10.4028\/www.scientific.net\/JBBTE.7.7"},{"key":"e_1_2_8_40_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0142-9612(00)00306-9"},{"key":"e_1_2_8_41_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.cuor.2008.05.003"},{"key":"e_1_2_8_42_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2009.07.007"},{"key":"e_1_2_8_43_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2014.03.044"}],"container-title":["Journal of Biomedical Materials Research Part B: Applied Biomaterials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fjbm.b.33944","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jbm.b.33944","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/jbm.b.33944","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jbm.b.33944","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,6,24]],"date-time":"2024-06-24T22:18:58Z","timestamp":1719267538000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jbm.b.33944"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,6,21]]},"references-count":42,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2018,4]]}},"alternative-id":["10.1002\/jbm.b.33944"],"URL":"https:\/\/doi.org\/10.1002\/jbm.b.33944","archive":["Portico"],"relation":{},"ISSN":["1552-4973","1552-4981"],"issn-type":[{"value":"1552-4973","type":"print"},{"value":"1552-4981","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,6,21]]}}}