{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T14:45:18Z","timestamp":1786977918794,"version":"build-2736575974"},"reference-count":73,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2017,9,23]],"date-time":"2017-09-23T00:00:00Z","timestamp":1506124800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"name":"Australian Federal Government through an Australian Government Research Training Program Scholarship"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Biomed Mater Res"],"published-print":{"date-parts":[[2018,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    This paper studied the influence of two common sterilization techniques, ethylene oxide (EO) and gamma irradiation (GI), on the corrosion rate of four Mg\u2010based materials in CO\n                    <jats:sub>2<\/jats:sub>\n                    \u2010bicarbonate buffered Hanks\u2019 solution. The four materials were: high\u2010purity (HP)\u2010Mg, ZE41, ultra\u2010high purity (XHP)\u2010Mg, and XHP\u2010ZX00. The corrosion rate was measured through mass loss (\n                    <jats:italic>P<\/jats:italic>\n                    <jats:sub>m<\/jats:sub>\n                    ) and hydrogen evolution (\n                    <jats:italic>P<\/jats:italic>\n                    <jats:sub>H<\/jats:sub>\n                    ). Two\u2010way analysis of variance (ANOVA) was conducted to assess the effect of the sterilization techniques on the corrosion rates across the four materials. The ANOVA analyzed the variables of (1) material, (2) sterilization condition (EO, GI, and an unsterilized control group), and (3) the interaction between these two independent variables. Neither sterilization technique (EO and GI) significantly influenced the corrosion rate as measured by\n                    <jats:italic>P<\/jats:italic>\n                    <jats:sub>m<\/jats:sub>\n                    (\n                    <jats:italic>p<\/jats:italic>\n                    \u2009&lt;\u20090.84) nor\n                    <jats:italic>P<\/jats:italic>\n                    <jats:sub>H<\/jats:sub>\n                    (\n                    <jats:italic>p<\/jats:italic>\n                    \u2009&lt;\u20090.08). This result was consistent across the four materials tested, as there was no interaction between the test variables of material and sterilization condition for\n                    <jats:italic>P<\/jats:italic>\n                    <jats:sub>m<\/jats:sub>\n                    (\n                    <jats:italic>p<\/jats:italic>\n                    \u2009&lt;\u20090.49) or\n                    <jats:italic>P<\/jats:italic>\n                    <jats:sub>H<\/jats:sub>\n                    (\n                    <jats:italic>p<\/jats:italic>\n                    \u2009&lt;\u20090.27). As neither EO nor GI influenced the corrosion rates, either of these techniques warrants consideration for use on Mg\u2010based medical implants and devices. \u00a9 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1907\u20131917, 2018.\n                  <\/jats:p>","DOI":"10.1002\/jbm.b.34004","type":"journal-article","created":{"date-parts":[[2017,9,23]],"date-time":"2017-09-23T11:16:47Z","timestamp":1506165407000},"page":"1907-1917","source":"Crossref","is-referenced-by-count":24,"title":["The influence of two common sterilization techniques on the corrosion of Mg and its alloys for biomedical applications"],"prefix":"10.1002","volume":"106","author":[{"given":"Sean","family":"Johnston","sequence":"first","affiliation":[{"name":"Materials Engineering, School of Mechanical and Mining Engineering The University of Queensland Brisbane QLD 4072 Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhiming","family":"Shi","sequence":"additional","affiliation":[{"name":"Materials Engineering, School of Mechanical and Mining Engineering The University of Queensland Brisbane QLD 4072 Australia"},{"name":"Centre for Advanced Materials Processing and Manufacturing (AMPAM), The University of Queensland Brisbane QLD 4072 Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cherilyn","family":"Hoe","sequence":"additional","affiliation":[{"name":"Materials Engineering, School of Mechanical and Mining Engineering The University of Queensland Brisbane QLD 4072 Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter J.","family":"Uggowitzer","sequence":"additional","affiliation":[{"name":"Laboratory of Metal Physics and Technology, Department of Materials ETH Zurich 8093 Zurich Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martina","family":"Cihova","sequence":"additional","affiliation":[{"name":"Laboratory of Metal Physics and Technology, Department of Materials ETH Zurich 8093 Zurich Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J\u00f6rg F.","family":"L\u00f6ffler","sequence":"additional","affiliation":[{"name":"Laboratory of Metal Physics and Technology, Department of Materials ETH Zurich 8093 Zurich Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew S.","family":"Dargusch","sequence":"additional","affiliation":[{"name":"Centre for Advanced Materials Processing and Manufacturing (AMPAM), The University of Queensland Brisbane QLD 4072 Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrej","family":"Atrens","sequence":"additional","affiliation":[{"name":"Materials Engineering, School of Mechanical and Mining Engineering The University of Queensland Brisbane QLD 4072 Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2017,9,23]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1128\/9781555816445"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0195-6701(99)90065-8"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajic.2008.12.010"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2011.11.026"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2013.08.035"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mser.2014.01.001"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.b.32680"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.a.34741"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.a.31170"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11837-015-1773-1"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehw196"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1002\/adem.201400434"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.msec.2013.06.004"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1002\/adem.201100074"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1515\/bnm-2015-0005"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2012.02.018"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2007.12.021"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.b.31982"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2004.09.049"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mseb.2011.02.010"},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2009.10.012"},{"issue":"4","key":"e_1_2_7_23_1","doi-asserted-by":"crossref","first-page":"1609","DOI":"10.1002\/jbm.a.32639","article-title":"Influence of a magnesium\u2010fluoride coating of magnesium\u2010based implants (MgCa0.8) on degradation in a rabbit model","volume":"93","author":"Thomann M","year":"2010","journal-title":"J Biomed Mater Res Part A"},{"key":"e_1_2_7_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2010.10.031"},{"key":"e_1_2_7_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2009.06.028"},{"key":"e_1_2_7_26_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.a.31293"},{"key":"e_1_2_7_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2015.02.010"},{"key":"e_1_2_7_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2009.11.111"},{"key":"e_1_2_7_29_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.a.31273"},{"key":"e_1_2_7_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2008.12.001"},{"key":"e_1_2_7_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.msec.2012.04.032"},{"key":"e_1_2_7_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2005.07.037"},{"issue":"1","key":"e_1_2_7_33_1","first-page":"2):82","article-title":"Comparison of the resorbable magnesium. alloys LAE442 und MgCa0.8 concerning their mechanical properties, their progress of degradation and the bone\u2010implant\u2010contact after 12 months implantation duration in a rabbit model","volume":"40","author":"Thomann M","year":"2009","journal-title":"Materialwiss Werkstofftech"},{"key":"e_1_2_7_34_1","doi-asserted-by":"publisher","DOI":"10.1002\/mawe.200800378"},{"key":"e_1_2_7_35_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2010.08.020"},{"key":"e_1_2_7_36_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mseb.2011.07.011"},{"key":"e_1_2_7_37_1","doi-asserted-by":"publisher","DOI":"10.1136\/heart.89.6.651"},{"key":"e_1_2_7_38_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8183.2004.04081.x"},{"key":"e_1_2_7_39_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.20727"},{"key":"e_1_2_7_40_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2012.04.028"},{"key":"e_1_2_7_41_1","volume-title":"Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008","author":"Rutala W","year":"2008"},{"key":"e_1_2_7_42_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajic.2006.10.014"},{"key":"e_1_2_7_43_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jchas.2008.09.010"},{"issue":"11","key":"e_1_2_7_44_1","first-page":"757","article-title":"Physical and mechanical behavior of electron\u2010beam irradiated and ethylene oxide sterilized multiblock polyester","volume":"11","author":"El Fray M","year":"2000","journal-title":"J Mater Sci"},{"key":"e_1_2_7_45_1","unstructured":"Association for the Advancement of Medical Instrumentation. Process Control Guidelines for Gamma Radiation Sterilization of Medical Devices. Arlington VA (USA): Association for the Advancement of Medical Instrumentation;1984."},{"key":"e_1_2_7_46_1","first-page":"1","article-title":"The use of the ionizing radiation technique for tissue sterilization: The International Atomic Energy Agency Experience","author":"Morales Pedraza J.","year":"2012","journal-title":"Nova Sci"},{"key":"e_1_2_7_47_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.corsci.2013.06.019"},{"key":"e_1_2_7_48_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.corsci.2015.09.018"},{"key":"e_1_2_7_49_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.corsci.2014.09.008"},{"key":"e_1_2_7_50_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2016.06.025"},{"key":"e_1_2_7_51_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11837-014-0875-5"},{"key":"e_1_2_7_52_1","doi-asserted-by":"publisher","DOI":"10.1038\/nmat2542"},{"key":"e_1_2_7_53_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.a.31887"},{"key":"e_1_2_7_54_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.corsci.2016.03.007"},{"key":"e_1_2_7_55_1","article-title":"Process and apparatus for vacuum distillation of high\u2010purity magnesium","author":"Wegmann C","year":"2013","journal-title":"Google Patents"},{"key":"e_1_2_7_56_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.corsci.2010.10.008"},{"key":"e_1_2_7_57_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.corsci.2011.06.030"},{"key":"e_1_2_7_58_1","doi-asserted-by":"publisher","DOI":"10.2355\/isijinternational.38.913"},{"key":"e_1_2_7_59_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2011.11.014"},{"key":"e_1_2_7_60_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.corsci.2010.09.016"},{"key":"e_1_2_7_61_1","first-page":"254","article-title":"An hydrogen evolution method for the estimation of the corrosion rate of magnesium alloys","volume":"2001","author":"Song G","year":"2001","journal-title":"Magnesium Technol"},{"key":"e_1_2_7_62_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.corsci.2013.06.032"},{"key":"e_1_2_7_63_1","first-page":"8862","article-title":"Thermodynamics: an engineering approach","volume":"1000","author":"Cengel YA","year":"2002","journal-title":"Sea"},{"key":"e_1_2_7_64_1","doi-asserted-by":"publisher","DOI":"10.1016\/0277-5379(82)90114-6"},{"key":"e_1_2_7_65_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jma.2013.09.003"},{"key":"e_1_2_7_66_1","doi-asserted-by":"publisher","DOI":"10.1063\/1.1722570"},{"key":"e_1_2_7_67_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.corsci.2010.07.019"},{"key":"e_1_2_7_68_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.cossms.2009.04.001"},{"key":"e_1_2_7_69_1","doi-asserted-by":"publisher","DOI":"10.1002\/adem.200310405"},{"key":"e_1_2_7_70_1","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1527-2648(199909)1:1<11::AID-ADEM11>3.0.CO;2-N"},{"key":"e_1_2_7_71_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.corsci.2008.12.015"},{"key":"e_1_2_7_72_1","doi-asserted-by":"publisher","DOI":"10.1002\/adem.200800046"},{"key":"e_1_2_7_73_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11706-015-0299-3"},{"key":"e_1_2_7_74_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.msec.2008.12.015"}],"container-title":["Journal of Biomedical Materials Research Part B: Applied Biomaterials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fjbm.b.34004","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jbm.b.34004","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,6,27]],"date-time":"2024-06-27T02:02:22Z","timestamp":1719453742000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jbm.b.34004"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,9,23]]},"references-count":73,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2018,7]]}},"alternative-id":["10.1002\/jbm.b.34004"],"URL":"https:\/\/doi.org\/10.1002\/jbm.b.34004","archive":["Portico"],"relation":{},"ISSN":["1552-4973","1552-4981"],"issn-type":[{"value":"1552-4973","type":"print"},{"value":"1552-4981","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,9,23]]}}}