{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,5]],"date-time":"2026-03-05T14:49:28Z","timestamp":1772722168028,"version":"3.50.1"},"reference-count":45,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2022,1,28]],"date-time":"2022-01-28T00:00:00Z","timestamp":1643328000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100012331","name":"Agentschap Innoveren en Ondernemen","doi-asserted-by":"publisher","award":["HBC.2018.0093"],"award-info":[{"award-number":["HBC.2018.0093"]}],"id":[{"id":"10.13039\/100012331","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100004040","name":"KU Leuven","doi-asserted-by":"publisher","award":["STG\/17\/024"],"award-info":[{"award-number":["STG\/17\/024"]}],"id":[{"id":"10.13039\/501100004040","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Biomed Mater Res"],"published-print":{"date-parts":[[2022,6]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The wear of a novel temporomandibular joint (TMJ) prosthesis was evaluated in an animal model. The prosthesis consisted of an additively manufactured titanium alloy (Ti<jats:sub>6<\/jats:sub>Al<jats:sub>4<\/jats:sub>V) mandibular condyle and glenoid fossa created through selective laser melting, with a machined vitamin E\u2010enriched ultra\u2010high molecular weight polyethylene (UHMWPE) surface attached to the fossa. Thirteen TMJ prosthesis were implanted in sheep, six of which had condylar heads coated with HadSat\u00ae diamond\u2010like carbon (H\u2010DLC). Euthanasia took place after 288\u2009days, equaling 22\u2009years of human mastication. Linear and volumetric wear analysis of the fossa was performed by optical scanning. The condylar head surfaces were assessed by scanning electron and confocal laser microscopy. The average linear UHMWPE wear, when combined with the coated condyle, was 0.67\u2009\u00b1\u20090.28\u2009mm (range: 0.34\u20131.15\u2009mm), not significantly differing (<jats:italic>p<\/jats:italic>\u00a0=\u00a0.3765, <jats:italic>t<\/jats:italic>\u2010test) from the non\u2010coated combination average (0.88\u2009\u00b1\u20090.41\u2009mm; range: 0.28\u20131.48\u2009mm). The respective mean volumetric wear volumes were 25.29\u2009\u00b1\u200911.43\u2009mm<jats:sup>3<\/jats:sup> and 45.85\u2009\u00b1\u200922.01\u2009mm<jats:sup>3<\/jats:sup>, not significantly differing (<jats:italic>p<\/jats:italic>\u00a0=\u00a0.1448, <jats:italic>t<\/jats:italic>\u2010test). Analysis of the coated condylar surface produced a mean Ra of 0.12\u2009\u00b1\u20090.04\u2009\u03bcm and Sa of 0.69\u2009\u00b1\u20090.07\u2009\u03bcm. The non\u2010coated condylar surface measured a mean Ra of 0.28\u2009\u00b1\u20090.17\u2009\u03bcm and Sa of 2.40\u2009\u00b1\u20092.08\u2009\u03bcm. Both Sa (<jats:italic>p<\/jats:italic>\u00a0=\u00a0.0083, Mann\u2013Whitney <jats:italic>U<\/jats:italic> test) and Ra (<jats:italic>p<\/jats:italic>\u00a0=\u00a0.0182, Mann\u2013Whitney <jats:italic>U<\/jats:italic> test), differed significantly. The prosthesis exhibits acceptable wear resistance and addition of the H\u2010DLC\u2010coating significantly improved long\u2010term condylar surface smoothness.<\/jats:p>","DOI":"10.1002\/jbm.b.35010","type":"journal-article","created":{"date-parts":[[2022,1,28]],"date-time":"2022-01-28T11:46:12Z","timestamp":1643370372000},"page":"1425-1438","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Surface wear in a custom manufactured temporomandibular joint prosthesis"],"prefix":"10.1002","volume":"110","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2996-5431","authenticated-orcid":false,"given":"Nikolas","family":"De Meurechy","sequence":"first","affiliation":[{"name":"European Face Centre Universitair Ziekenhuis Brussel  Brussels Belgium"},{"name":"Doctoral School of Life Sciences and Medicine Vrije Universiteit Brussel  Brussels Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Merve K\u00fcbra","family":"Aktan","sequence":"additional","affiliation":[{"name":"Department of Materials Engineering KU Leuven  Heverlee Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bart","family":"Boeckmans","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering KU Leuven  Heverlee Belgium"},{"name":"Flanders Make  Heverlee Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stijn","family":"Huys","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering KU Leuven  Heverlee Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Denis R.","family":"Verwilghen","sequence":"additional","affiliation":[{"name":"Sydney School of Veterinary Sciences, Faculty of Science University of Sydney  Sydney Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4890-0177","authenticated-orcid":false,"given":"Annabel","family":"Braem","sequence":"additional","affiliation":[{"name":"Department of Materials Engineering KU Leuven  Heverlee Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maurice Y.","family":"Mommaerts","sequence":"additional","affiliation":[{"name":"European Face Centre Universitair Ziekenhuis Brussel  Brussels Belgium"},{"name":"Doctoral School of Life Sciences and Medicine Vrije Universiteit Brussel  Brussels Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2022,1,28]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.joms.2016.04.011"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijom.2017.10.001"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.pmatsci.2008.06.004"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(18)32531-5"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1054\/ijom.2001.0175"},{"key":"e_1_2_9_7_1","first-page":"63","article-title":"Engineering alloplastic temporomandibular joint replacements","volume":"13","author":"Sinno H","year":"2010","journal-title":"McGill J Med"},{"key":"e_1_2_9_8_1","first-page":"131","article-title":"Measurement of wear in orthopedic prosthesis","volume":"121","author":"Sagbas B","year":"2012","journal-title":"Proc Int Cong Adv Appl Phys Mater Sci"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200112000-00008"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.joms.2008.09.010"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijom.2018.01.014"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.bjoms.2019.08.009"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1034\/j.1399-0020.2000.290501.x"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0142-9612(99)00042-3"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2016.01.001"},{"key":"e_1_2_9_16_1","first-page":"984","article-title":"Evaluation of temporomandibular joint prostheses. Review of the literature from 1946 to 1994 and implications for future prosthesis designs","volume":"53","author":"Loon JP","year":"1995","journal-title":"J Oral Maxillofac Surg"},{"key":"e_1_2_9_17_1","first-page":"159","volume-title":"Human Musculoskeletal Biomechanics","author":"Ingawal\u00e9 SM","year":"2012"},{"key":"e_1_2_9_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.morpho.2016.06.002"},{"key":"e_1_2_9_19_1","doi-asserted-by":"publisher","DOI":"10.1089\/ten.teb.2017.0341"},{"key":"e_1_2_9_20_1","doi-asserted-by":"publisher","DOI":"10.1079\/BJN19910096"},{"key":"e_1_2_9_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcms.2019.11.018"},{"key":"e_1_2_9_22_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10856-006-0016-y"},{"key":"e_1_2_9_23_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-010-1717-6"},{"key":"e_1_2_9_24_1","doi-asserted-by":"publisher","DOI":"10.1023\/A:1015750112343"},{"key":"e_1_2_9_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcms.2021.01.029"},{"key":"e_1_2_9_26_1","first-page":"360","article-title":"Dental implants, what should be known before starting an in vitro study","volume":"2","author":"Verplancke K","year":"2011","journal-title":"Conf Sustainable Constr Des"},{"key":"e_1_2_9_27_1","doi-asserted-by":"publisher","DOI":"10.1177\/028418519003100201"},{"key":"e_1_2_9_28_1","doi-asserted-by":"publisher","DOI":"10.1054\/arth.2002.33664"},{"key":"e_1_2_9_29_1","doi-asserted-by":"publisher","DOI":"10.1080\/000164701753606644"},{"key":"e_1_2_9_30_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200111000-00016"},{"key":"e_1_2_9_31_1","doi-asserted-by":"publisher","DOI":"10.1155\/2008\/628120"},{"key":"e_1_2_9_32_1","first-page":"357","article-title":"Influence of implant design and bone quality on stress\/strain distribution in bone around implants: a 3\u2010dimensional finite element analysis","volume":"18","author":"Tada S","year":"2003","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"15","key":"e_1_2_9_33_1","first-page":"195","article-title":"Experimental pullout testing and comparison of variables in transpedicular screw fixation. A biomechanical study","volume":"1990","author":"Skinner R","year":"1976","journal-title":"Spine"},{"key":"e_1_2_9_34_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(98)80002-8"},{"key":"e_1_2_9_35_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.a.32161"},{"key":"e_1_2_9_36_1","unstructured":"TubbCC LongarayJA HerreraL EssnerAP MolloyRM.The effect of femoral component roughness on the wear of total knee implants.Orthop Res Soc.2011;36."},{"key":"e_1_2_9_37_1","doi-asserted-by":"publisher","DOI":"10.1243\/0954411001535390"},{"key":"e_1_2_9_38_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.apsusc.2004.04.032"},{"key":"e_1_2_9_39_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0928-4931(02)00106-6"},{"key":"e_1_2_9_40_1","doi-asserted-by":"publisher","DOI":"10.1023\/A:1008917727604"},{"key":"e_1_2_9_41_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.b.30768"},{"key":"e_1_2_9_42_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mser.2004.11.001"},{"issue":"1","key":"e_1_2_9_43_1","first-page":"1","article-title":"Effects of surface coating on reducing friction and wear of orthopaedic implants","volume":"15","author":"Ching HA","year":"2014","journal-title":"Sience Technol Adv Mater"},{"key":"e_1_2_9_44_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.surfcoat.2010.06.048"},{"key":"e_1_2_9_45_1","doi-asserted-by":"publisher","DOI":"10.1155\/2015\/485975"},{"key":"e_1_2_9_46_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mser.2014.04.002"}],"container-title":["Journal of Biomedical Materials Research Part B: Applied Biomaterials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jbm.b.35010","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/jbm.b.35010","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jbm.b.35010","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,25]],"date-time":"2023-08-25T23:05:54Z","timestamp":1693004754000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jbm.b.35010"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,28]]},"references-count":45,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2022,6]]}},"alternative-id":["10.1002\/jbm.b.35010"],"URL":"https:\/\/doi.org\/10.1002\/jbm.b.35010","archive":["Portico"],"relation":{},"ISSN":["1552-4973","1552-4981"],"issn-type":[{"value":"1552-4973","type":"print"},{"value":"1552-4981","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,1,28]]},"assertion":[{"value":"2021-01-25","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-12-09","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-01-28","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}