{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T10:53:31Z","timestamp":1772794411632,"version":"3.50.1"},"reference-count":32,"publisher":"Wiley","issue":"11","license":[{"start":{"date-parts":[[2022,6,9]],"date-time":"2022-06-09T00:00:00Z","timestamp":1654732800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001659","name":"Deutsche Forschungsgemeinschaft","doi-asserted-by":"publisher","award":["2751\/1\u20101"],"award-info":[{"award-number":["2751\/1\u20101"]}],"id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Biomed Mater Res"],"published-print":{"date-parts":[[2022,11]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>For cochlear implants (CI) a final position of the electrode array (EA) along the inner wall of the spirally shaped cochlea is considered to be beneficial because it results in a closer proximity to the auditory nerve fibers. A shape memory effect (SME) could facilitate such shift of the EA toward the cochlear inner wall, but its implementation remains to be solved. The current study presents an EA prototype featuring the SME with minute adjustments of the material properties of Nitinol, a shape memory alloy, in combination with a suitable cooling strategy to prevent premature curling. Ten samples were successfully inserted by a CI surgeon into an artificial cochlear model submerged into a temperature\u2010controllable water bath to simulate temporary hypothermia of the inner ear (31\u00b0C). Gentle insertions were possible, with an average insertion speed of 0.81\u2009\u00b1\u20090.14\u2009mm\/s. After recovery of body temperature, the desired position shift toward the modiolus was observed in all trials. Angular insertion depth increased by approximately 81.8\u00b0\u2009\u00b1\u200923.4\u00b0. We demonstrate for the first time that using the body temperature responsive SME for perimodiolar EA positioning is feasible and does not impede a gentle surgical insertion.<\/jats:p>","DOI":"10.1002\/jbm.b.35107","type":"journal-article","created":{"date-parts":[[2022,6,9]],"date-time":"2022-06-09T09:55:10Z","timestamp":1654768510000},"page":"2494-2505","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Toward a cochlear implant electrode array with shape memory effect for post\u2010insertion perimodiolar positioning"],"prefix":"10.1002","volume":"110","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7223-3618","authenticated-orcid":false,"given":"Thomas S.","family":"Rau","sequence":"first","affiliation":[{"name":"Department of Otolaryngology Hannover Medical School  Hannover Germany"},{"name":"Cluster of Excellence EXC 2177\/1 \u201cHearing4all\u201d Hannover Medical School  Hannover Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tim","family":"Ehmann","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology Hannover Medical School  Hannover Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M. Geraldine","family":"Zuniga","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology Hannover Medical School  Hannover Germany"},{"name":"Cluster of Excellence EXC 2177\/1 \u201cHearing4all\u201d Hannover Medical School  Hannover Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Katarzyna","family":"Plaskonka","sequence":"additional","affiliation":[{"name":"G.RAU GmbH &amp; Co. KG  Pforzheim Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andreas","family":"Keck","sequence":"additional","affiliation":[{"name":"G.RAU GmbH &amp; Co. KG  Pforzheim Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Omid","family":"Majdani","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology Hannover Medical School  Hannover Germany"},{"name":"Cluster of Excellence EXC 2177\/1 \u201cHearing4all\u201d Hannover Medical School  Hannover Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas","family":"Lenarz","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology Hannover Medical School  Hannover Germany"},{"name":"Cluster of Excellence EXC 2177\/1 \u201cHearing4all\u201d Hannover Medical School  Hannover Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2022,6,9]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0b013e3181c6b831"},{"key":"e_1_2_9_3_1","first-page":"1","article-title":"Current profile of adults presenting for preoperative Cochlear implant evaluation","volume":"22","author":"Holder JT","year":"2018","journal-title":"Trends Hear"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0174900"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0000000000000949"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.heares.2017.10.005"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0183674"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1002\/lary.29224"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1002\/lary.24728"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0b013e3182741aa7"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.5152\/iao.2018.6372"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2010.10.004"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.3109\/13645700009063057"},{"key":"e_1_2_9_14_1","unstructured":"Corbett S. S. J. W.Swanson J.Martyniuk T. R.Clary F. A.Spelman B.Clopton A. H.Voie andC. N.Jolly.Multi\u2010electrode Cochlear implant and method of manufacturing the same. US patent 5 630 839.1997."},{"key":"e_1_2_9_15_1","first-page":"800,500","article-title":"Cochlear implant with Schape memory material and method for implanting the same","volume":"5","author":"Spelman FA","year":"1998","journal-title":"Patent: US"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1155\/2013\/250915"},{"key":"e_1_2_9_17_1","doi-asserted-by":"publisher","DOI":"10.1515\/cdbme-2018-0036"},{"key":"e_1_2_9_18_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00405-016-3955-z"},{"key":"e_1_2_9_19_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11837-003-0243-3"},{"key":"e_1_2_9_20_1","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0000000000000989"},{"key":"e_1_2_9_21_1","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0000000000002608"},{"key":"e_1_2_9_22_1","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0000000000002373"},{"key":"e_1_2_9_23_1","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0000000000000529"},{"key":"e_1_2_9_24_1","doi-asserted-by":"publisher","DOI":"10.3389\/fneur.2020.620691"},{"key":"e_1_2_9_25_1","first-page":"283","article-title":"On the stiffness properties of custom\u2010made silicone dummies for the development of cochlear implant electrode arrays with a shape memory wire","volume":"99","author":"Zuniga MG","year":"2020","journal-title":"Laryngorhinootologie"},{"key":"e_1_2_9_26_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00405-018-5159-1"},{"key":"e_1_2_9_27_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11665-009-9451-5"},{"key":"e_1_2_9_28_1","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e318219f6ac"},{"key":"e_1_2_9_29_1","doi-asserted-by":"publisher","DOI":"10.1177\/0194599817704391"},{"key":"e_1_2_9_30_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11548-020-02243-7"},{"key":"e_1_2_9_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.heares.2021.108425"},{"key":"e_1_2_9_32_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00405-020-06070-z"},{"key":"e_1_2_9_33_1","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0000000000003148"}],"container-title":["Journal of Biomedical Materials Research Part B: Applied Biomaterials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jbm.b.35107","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/jbm.b.35107","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jbm.b.35107","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,23]],"date-time":"2023-08-23T04:26:25Z","timestamp":1692764785000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jbm.b.35107"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,6,9]]},"references-count":32,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2022,11]]}},"alternative-id":["10.1002\/jbm.b.35107"],"URL":"https:\/\/doi.org\/10.1002\/jbm.b.35107","archive":["Portico"],"relation":{},"ISSN":["1552-4973","1552-4981"],"issn-type":[{"value":"1552-4973","type":"print"},{"value":"1552-4981","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,6,9]]},"assertion":[{"value":"2021-12-07","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-05-20","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-06-09","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}