{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T03:40:33Z","timestamp":1792640433693,"version":"4.5.0"},"reference-count":63,"publisher":"Wiley","issue":"12","license":[{"start":{"date-parts":[[2022,6,21]],"date-time":"2022-06-21T00:00:00Z","timestamp":1655769600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Biomed Mater Res"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Nitinol (NiTi), a nickel\u2013titanium alloy, has been used for various cardiovascular, orthopedic, fracture fixation, and orthodontic devices. As with most other metallic biomaterials, the corrosion resistance and biocompatibility of NiTi are primarily determined by the properties of the surface oxide layer such as thickness, chemical composition, structure, uniformity, and stability. Currently, a number of finishing methods are used to improve the properties of surface oxide of NiTi with an ultimate goal to produce a defect\u2010free, impurity\u2010free, thin homogeneous oxide layer that is stable and composed of only titanium dioxide (TiO<jats:sub>2<\/jats:sub>) with negligible amount of Ni species. This review discusses the effects of various surface finishing methods such as mechanical polishing, electropolishing, magnetoelectropolishing, heat treatments at different temperatures, passivation, chemical etching, boiling in water, hydrogen peroxide treatment, and sterilization techniques (steam autoclave, ethylene oxide, dry heat, peracetic acid, and plasma\u2010based treatments) on the properties of a surface oxide layer and how it impacts the corrosion resistance of NiTi. Considering the findings of the literature review, a checklist has been provided to assist with choosing finishing\/sterilization methods and relevant rationale and recommendations to consider when selecting a surface finishing process for NiTi used in implantable medical devices.<\/jats:p>","DOI":"10.1002\/jbm.b.35112","type":"journal-article","created":{"date-parts":[[2022,6,22]],"date-time":"2022-06-22T05:34:46Z","timestamp":1655876086000},"page":"2763-2778","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":35,"title":["Surface finishing of <scp>N<\/scp>itinol for implantable medical devices: A review"],"prefix":"10.1002","volume":"110","author":[{"given":"Gopinath","family":"Mani","sequence":"first","affiliation":[{"name":"Division of Science and Technology Abbott  St. Paul Minnesota USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deanna","family":"Porter","sequence":"additional","affiliation":[{"name":"Division of Science and Technology Abbott  St. Paul Minnesota USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kent","family":"Grove","sequence":"additional","affiliation":[{"name":"Division of Science and Technology Abbott  St. Paul Minnesota USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shell","family":"Collins","sequence":"additional","affiliation":[{"name":"Division of Science and Technology Abbott  St. Paul Minnesota USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andreas","family":"Ornberg","sequence":"additional","affiliation":[{"name":"Division of Science and Technology Abbott  St. Paul Minnesota USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Shulfer","sequence":"additional","affiliation":[{"name":"Division of Science and Technology Abbott  St. Paul Minnesota USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2022,6,21]]},"reference":[{"key":"e_1_2_6_2_1","volume-title":"Introduction to Biomaterials Basic Theory with Engineering Applications","author":"Agrawal CM","year":"2014"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2008.01.013"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2015.03.025"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1063\/1.5133981"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/B978-0-08-055294-1.00014-3"},{"key":"e_1_2_6_7_1","first-page":"501483\u20101","article-title":"Biomedical applications of shape memory alloys","volume":"1","author":"Petrini L","year":"2011","journal-title":"J Metall"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.4028\/www.scientific.net\/MSF.394-395.285"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.msea.2007.04.039"},{"key":"e_1_2_6_10_1","first-page":"01004\u20101\u201301004\u20106","article-title":"Vacuum arc melting processes for biomedical Ni\u2010Ti shape memory alloy","volume":"30","author":"Tsa DC","year":"2015","journal-title":"MATEC Web of Conferences"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2015.07.003"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.b.30006"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11665-012-0366-1"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.matdes.2019.108295"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmapro.2019.01.003"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.b.10017"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-4636(199824)43:4<433::AID-JBM11>3.0.CO;2-#"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1096-9918(199806)26:7<483::AID-SIA388>3.0.CO;2-5"},{"key":"e_1_2_6_19_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.b.31865"},{"key":"e_1_2_6_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.msec.2011.08.022"},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.1007\/s40830-015-0028-x"},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.msec.2011.11.007"},{"key":"e_1_2_6_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0142-9612(01)00299-X"},{"key":"e_1_2_6_24_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.b.34794"},{"key":"e_1_2_6_25_1","first-page":"357","volume-title":"SMST\u20102003 Proceedings of the International Conference on Shape Memory and Superelastic Technologies","author":"Zhu L","year":"2003"},{"key":"e_1_2_6_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2008.10.014"},{"key":"e_1_2_6_27_1","first-page":"69","article-title":"Surface, corrosion and biocompatibility aspects of Nitinol as an implant material","volume":"12","author":"Shabalovskaya SA","year":"2002","journal-title":"Biomed Mater Eng"},{"key":"e_1_2_6_28_1","doi-asserted-by":"publisher","DOI":"10.1615\/JLongTermEffMedImplants.v19.i2.30"},{"key":"e_1_2_6_29_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.b.34599"},{"key":"e_1_2_6_30_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.2007.01220.x"},{"key":"e_1_2_6_31_1","first-page":"169","volume-title":"IARC Monographs: Arsenic, Metals, Fibres, and Dusts \u2010 A Review of Human Carcinogens, WHO\/IARC","year":"2012"},{"key":"e_1_2_6_32_1","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-4636(199804)40:1<40::AID-JBM5>3.0.CO;2-R"},{"key":"e_1_2_6_33_1","unstructured":"US Food and Drug Administration Center for Devices and Radiological Health. Technical Considerations for Non\u2010Clinical Assessment of Medical Devices Containing Nitinol Guidance for Industry and Food and Drug Administration Staff. Accessed February 28 2022.https:\/\/www.fda.gov\/regulatory\u2010information\/search\u2010fda\u2010guidance\u2010documents\/technical\u2010considerations\u2010non\u2010clinical\u2010assessment\u2010medical\u2010devices\u2010containing\u2010nitinol"},{"key":"e_1_2_6_34_1","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-4636(200001)49:1<88::AID-JBM11>3.0.CO;2-I"},{"key":"e_1_2_6_35_1","doi-asserted-by":"publisher","DOI":"10.1002\/1097-4636(20000915)51:4<685::AID-JBM17>3.0.CO;2-S"},{"key":"e_1_2_6_36_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.a.30720"},{"key":"e_1_2_6_37_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2017.08.029"},{"key":"e_1_2_6_38_1","volume-title":"Standard Test Method for Conducting Cyclic Potentiodynamic Polarization Measurements to Determine the Corrosion Susceptibility of Small Implant Devices","author":"ASTM F2129 \u2010 19a","year":"2019"},{"key":"e_1_2_6_39_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.b.33630"},{"key":"e_1_2_6_40_1","doi-asserted-by":"publisher","DOI":"10.3390\/ma14247789"},{"key":"e_1_2_6_41_1","doi-asserted-by":"publisher","DOI":"10.14331\/ijfps.2020.330135"},{"key":"e_1_2_6_42_1","unstructured":"US Food and Drug Administration Center for Devices and Radiological Health. Select Updates for Non\u2010Clinical Engineering Tests and Recommended Labeling for Intravascular Stents and Associated Delivery Systems. Accessed January 03 2022.https:\/\/www.fda.gov\/regulatory-information\/search-fda-guidance-documents\/select-updates-non-clinical-engineering-tests-and-recommended-labeling-intravascular-stents-and"},{"key":"e_1_2_6_43_1","doi-asserted-by":"publisher","DOI":"10.5006\/1.3292101"},{"key":"e_1_2_6_44_1","doi-asserted-by":"publisher","DOI":"10.3390\/met5010172"},{"issue":"1","key":"e_1_2_6_45_1","first-page":"71","article-title":"Science and industry of Electropolishing","volume":"71","author":"Chatterjee B","year":"2015","journal-title":"Galvanotechnik"},{"key":"e_1_2_6_46_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2006.11.042"},{"key":"e_1_2_6_47_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.10114"},{"key":"e_1_2_6_48_1","doi-asserted-by":"publisher","DOI":"10.1179\/174591908X345040"},{"issue":"3","key":"e_1_2_6_49_1","first-page":"1","article-title":"Surface investigation of NiTi rotary endodontic instruments after magnetoelectropolishing","volume":"1244","author":"Hryniewicz T","year":"2011","journal-title":"MRS Online Proc Library"},{"key":"e_1_2_6_50_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11665-011-9892-5"},{"key":"e_1_2_6_51_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10856-012-4696-1"},{"key":"e_1_2_6_52_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.b.10001"},{"key":"e_1_2_6_53_1","doi-asserted-by":"publisher","DOI":"10.3109\/13645700009063052"},{"key":"e_1_2_6_54_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.b.31407"},{"key":"e_1_2_6_55_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0142-9612(97)00210-X"},{"key":"e_1_2_6_56_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.tifs.2006.11.020"},{"key":"e_1_2_6_57_1","volume-title":"ASTM F86\u201321: Standard practice for surface preparation and marking of metallic surgical implants","author":"ASTM","year":"2021"},{"key":"e_1_2_6_58_1","doi-asserted-by":"publisher","DOI":"10.1023\/A:1020634014278"},{"key":"e_1_2_6_59_1","unstructured":"National Institute of Standards and Technology (NIST).Material Safety Data Sheet for Nickel. Accessed February 28 2022.https:\/\/www-s.nist.gov\/m-srmors\/msds\/986-MSDS.pdf"},{"key":"e_1_2_6_60_1","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-4636(199603)30:3<393::AID-JBM14>3.0.CO;2-L"},{"key":"e_1_2_6_61_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.b.32717"},{"key":"e_1_2_6_62_1","doi-asserted-by":"publisher","DOI":"10.1116\/1.579461"},{"key":"e_1_2_6_63_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.msea.2005.11.010"},{"key":"e_1_2_6_64_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0278-2391(96)90694-1"}],"container-title":["Journal of Biomedical Materials Research Part B: Applied Biomaterials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jbm.b.35112","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/jbm.b.35112","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jbm.b.35112","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,21]],"date-time":"2023-08-21T22:21:14Z","timestamp":1692656474000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jbm.b.35112"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,6,21]]},"references-count":63,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["10.1002\/jbm.b.35112"],"URL":"https:\/\/doi.org\/10.1002\/jbm.b.35112","archive":["Portico"],"relation":{},"ISSN":["1552-4973","1552-4981"],"issn-type":[{"value":"1552-4973","type":"print"},{"value":"1552-4981","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,6,21]]},"assertion":[{"value":"2022-03-22","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-06-08","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-06-21","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}