{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T06:36:34Z","timestamp":1786948594029,"version":"build-2736575974"},"reference-count":41,"publisher":"Wiley","issue":"9","license":[{"start":{"date-parts":[[2024,8,30]],"date-time":"2024-08-30T00:00:00Z","timestamp":1724976000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Biomed Mater Res"],"published-print":{"date-parts":[[2024,9]]},"abstract":"<jats:title>ABSTRACT<\/jats:title><jats:p>This study uses finite element analysis to investigate the potential application of shorter dental implants as a substitute for longer implants in the lower jaw (mandible). FEA allows the evaluation of the stress patterns around the implant\u2010bone interface, a critical factor for successful osseointegration. Ten models were generated, encompassing five long (L1\u2010L5) and five short implant models (S1\u2010S5) with variations in diameter and length. Hypermesh software was utilized to meticulously prepare the FEA models, ensuring accurate mesh generation. The FEA simulations were conducted under four distinct loading scenarios (100\u2009N occlusal load, 40\u2009N lateral load, 100\u2009N oblique at 30\u00b0, and 100\u2009N oblique at 45\u00b0) to realistically mimic the forces exerted during biting, using an ABAQUS CAE solver. The results revealed that the von Mises stress generated within the short implant models was demonstrably lower compared to their long implants. Additionally, a significant drop in stress was observed with increasing the diameter of the short implants, to a certain diameter range. These findings suggest the potential for successful substitution of long implant model L4 with short implant model S4 due to the demonstrably lower stress values achieved. Furthermore, the data indicates the possibility of utilizing short implant models S3 and S5 as alternatives to long implant models L3 and L5, respectively. These observations hold significant promise for evaluating the feasibility of replacing long implants with shorter variants, potentially leading to a reduction in implant\u2010related failures.<\/jats:p>","DOI":"10.1002\/jbm.b.35481","type":"journal-article","created":{"date-parts":[[2024,8,30]],"date-time":"2024-08-30T16:48:35Z","timestamp":1725036515000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Evaluating the Feasibility of Short Dental Implants as Alternatives to Long Dental Implants in Mandibular Bone: A Finite Element Study"],"prefix":"10.1002","volume":"112","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4525-2979","authenticated-orcid":false,"given":"Prathamesh","family":"Deshmukh","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering Dr. Vishwanath Karad MIT World Peace University  Pune India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4179-3524","authenticated-orcid":false,"given":"Pankaj","family":"Dhatrak","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering Dr. Vishwanath Karad MIT World Peace University  Pune India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2024,8,30]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.3390\/ma14143972"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2020.06.029"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-051X.2008.01274.x"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1177\/09544119221146617"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.matpr.2020.07.428"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2842.2010.02076.x"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.matpr.2020.06.097"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1902\/jop.2013.120745"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.matpr.2020.07.222"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2016.01.005"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijom.2021.02.014"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1111\/cid.12774"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.12517"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.1159\/000489672"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12903-022-02164-8"},{"key":"e_1_2_9_17_1","doi-asserted-by":"publisher","DOI":"10.9790\/1684\u20101500810914"},{"key":"e_1_2_9_18_1","doi-asserted-by":"publisher","DOI":"10.3390\/jcm8081103"},{"key":"e_1_2_9_19_1","doi-asserted-by":"publisher","DOI":"10.1067\/mpr.2001.115251"},{"key":"e_1_2_9_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jobcr.2020.10.004"},{"key":"e_1_2_9_21_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12668-019-00649-5"},{"key":"e_1_2_9_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.matpr.2020.12.396"},{"key":"e_1_2_9_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.asoc.2018.01.025"},{"key":"e_1_2_9_24_1","first-page":"15","article-title":"Biomaterials and Biomechanics of Oral and Maxillofacial Implants: Current Status and Future Developments","volume":"15","author":"Brunski J. B.","year":"2000","journal-title":"International Journal of Oral & Maxillofacial Implants"},{"key":"e_1_2_9_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2016.07.003"},{"key":"e_1_2_9_26_1","doi-asserted-by":"publisher","DOI":"10.1115\/1.4056951"},{"key":"e_1_2_9_27_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2007.01384.x"},{"key":"e_1_2_9_28_1","doi-asserted-by":"publisher","DOI":"10.1563\/1548-1336(1998)024<0080:EPOODI>2.3.CO;2"},{"key":"e_1_2_9_29_1","doi-asserted-by":"publisher","DOI":"10.3390\/jcm9103271"},{"key":"e_1_2_9_30_1","doi-asserted-by":"publisher","DOI":"10.3390\/jcm10050940"},{"key":"e_1_2_9_31_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-051X.2005.00747.x"},{"key":"e_1_2_9_32_1","doi-asserted-by":"publisher","DOI":"10.1080\/17434440.2020.1736040"},{"key":"e_1_2_9_33_1","doi-asserted-by":"publisher","DOI":"10.1063\/5.0057912"},{"key":"e_1_2_9_34_1","doi-asserted-by":"publisher","DOI":"10.3390\/prosthesis5020036"},{"key":"e_1_2_9_35_1","doi-asserted-by":"publisher","DOI":"10.1111\/jcpe.12694"},{"key":"e_1_2_9_36_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2020.103386"},{"key":"e_1_2_9_37_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40729-022-00404-8"},{"key":"e_1_2_9_38_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-98441-7"},{"key":"e_1_2_9_39_1","doi-asserted-by":"publisher","DOI":"10.4103\/1735-3327.276231"},{"key":"e_1_2_9_40_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40729-019-0202-6"},{"key":"e_1_2_9_41_1","doi-asserted-by":"publisher","DOI":"10.1097\/SCS.0b013e31826cf199"},{"key":"e_1_2_9_42_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.finel.2011.03.005"}],"container-title":["Journal of Biomedical Materials Research Part B: Applied Biomaterials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jbm.b.35481","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,9,15]],"date-time":"2024-09-15T13:22:44Z","timestamp":1726406564000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jbm.b.35481"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,30]]},"references-count":41,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2024,9]]}},"alternative-id":["10.1002\/jbm.b.35481"],"URL":"https:\/\/doi.org\/10.1002\/jbm.b.35481","archive":["Portico"],"relation":{},"ISSN":["1552-4973","1552-4981"],"issn-type":[{"value":"1552-4973","type":"print"},{"value":"1552-4981","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,8,30]]},"assertion":[{"value":"2024-06-27","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-08-14","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-08-30","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e35481"}}