{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T03:51:21Z","timestamp":1791863481911,"version":"4.3.4"},"reference-count":29,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2025,4,16]],"date-time":"2025-04-16T00:00:00Z","timestamp":1744761600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Biomed Mater Res"],"published-print":{"date-parts":[[2025,5]]},"abstract":"<jats:title>ABSTRACT<\/jats:title><jats:p>The United States Food and Drug Administration (FDA) recently announced an update to their 510(k) medical device sterility guidance to include vapor phase hydrogen peroxide (VH2O2) as an established \u2018Category A\u2019 sterilization process. This places VH2O2 in the same category as ethylene oxide (EO or EtO), which has demonstrated user and patient safety as well as microbiocidal effectiveness through scientific literature and FDA\u2010recognized consensus standards. For some implantable medical devices, the sterilant chemistry must diffuse through the polymers of construction to access sealed parts of the finished assembly to achieve an appropriate sterility assurance level. Diffusion of EO through materials has been well established over decades of successful use. However, the ability of VH2O2 to diffuse through materials of construction has not been demonstrated. In this work, we measured the diffusivity and permeability of VH2O2 for a series of increasing durometer poly(ether)urethanes (PEUs) commonly used in the construction of single\u2010use medical devices. The diffusion coefficients were 1\u2009\u00d7\u200910<jats:sup>\u22128<\/jats:sup>\u2009cm<jats:sup>2<\/jats:sup>\/s for PEU75D, 2\u2009\u00d7\u200910<jats:sup>\u22128<\/jats:sup>\u2009cm<jats:sup>2<\/jats:sup>\/s for PEU55D, and 5\u2009\u00d7\u200910<jats:sup>\u22128<\/jats:sup>\u2009cm<jats:sup>2<\/jats:sup>\/s for PEU80A. The permeabilities were calculated to be 4.7\u2009\u00d7\u200910<jats:sup>\u22126<\/jats:sup>\u2009cm<jats:sup>2<\/jats:sup>\/s and 1.3\u2009\u00d7\u200910<jats:sup>\u22125<\/jats:sup>\u2009cm<jats:sup>2<\/jats:sup>\/s for PEU55D and PEU80A, respectively. For a typical cardiac or neuromodulation lead, the PEU80A wall thickness is on the order of 0.013\u2009cm, resulting in penetration of hydrogen peroxide into the sealed construction in less than 10\u2009min, a timeframe that is a fraction of the total sterilization cycle time.<\/jats:p>","DOI":"10.1002\/jbm.b.35567","type":"journal-article","created":{"date-parts":[[2025,4,16]],"date-time":"2025-04-16T13:33:16Z","timestamp":1744810396000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Diffusion of Hydrogen Peroxide Through Medical Grade Poly(Ether)urethane: Analyzing Mechanisms of Sorption and Transport to Support Sterilization With Vapor Phase Hydrogen Peroxide"],"prefix":"10.1002","volume":"113","author":[{"given":"Ioan P. I.","family":"Gitsov","sequence":"first","affiliation":[{"name":"Global Technology and Innovation, Medtronic Inc  Minneapolis Minnesota USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yunzhi","family":"Liu","sequence":"additional","affiliation":[{"name":"Center for Devices and Radiological Health, FDA  Silver Spring Maryland USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2047-2913","authenticated-orcid":false,"given":"David M.","family":"Saylor","sequence":"additional","affiliation":[{"name":"Center for Devices and Radiological Health, FDA  Silver Spring Maryland USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Angela L.","family":"Hendrickx","sequence":"additional","affiliation":[{"name":"Global Technology and Innovation, Medtronic Inc  Minneapolis Minnesota USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ann M.","family":"Gronda","sequence":"additional","affiliation":[{"name":"Neurosciences, Medtronic Inc  Minneapolis Minnesota USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maruti N.","family":"Sinha","sequence":"additional","affiliation":[{"name":"Global Technology and Innovation, Medtronic Inc  Minneapolis Minnesota USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eric","family":"Long","sequence":"additional","affiliation":[{"name":"Global Technology and Innovation, Medtronic Inc  Minneapolis Minnesota USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shan","family":"Liu","sequence":"additional","affiliation":[{"name":"Center for Devices and Radiological Health, FDA  Silver Spring Maryland USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruibo","family":"Hu","sequence":"additional","affiliation":[{"name":"Center for Devices and Radiological Health, FDA  Silver Spring Maryland USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jon W.","family":"Weeks","sequence":"additional","affiliation":[{"name":"Center for Devices and Radiological Health, FDA  Silver Spring Maryland USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Eppihimer","sequence":"additional","affiliation":[{"name":"Center for Devices and Radiological Health, FDA  Silver Spring Maryland USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7812-3121","authenticated-orcid":false,"given":"Kimberly A.","family":"Chaffin","sequence":"additional","affiliation":[{"name":"Global Technology and Innovation, Medtronic Inc  Minneapolis Minnesota USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2025,4,16]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.2345\/0899\u20108205\u201054.s3.74"},{"key":"e_1_2_10_3_1","unstructured":"\u201cHydrogen Peroxide \u201dhttps:\/\/www.echa.europa.eu\/documents\/10162\/590965ca\u201033e7\u201043a0\u2010a109\u20103a9148870d07#:~:text=Hydrogen%20peroxide%20is%20normally%20a 24%20hours."},{"key":"e_1_2_10_4_1","unstructured":"\u201cCommunity Engagement on Ethylene Oxide (EtO) \u201dhttps:\/\/www.epa.gov\/hazardous\u2010air\u2010pollutants\u2010ethylene\u2010oxide\/forms\/community\u2010engagement\u2010ethylene\u2010oxide\u2010eto#:~:text=In%20August%202022%2C%20EPA%20completed people%20living%20in%20nearby%20communities."},{"key":"e_1_2_10_5_1","unstructured":"\u201cEPA Proposes New Standards to Protect Public Health Reduce Exposure to Ethylene Oxide Pollution \u201dhttps:\/\/www.epa.gov\/newsreleases\/epa\u2010proposes\u2010new\u2010standards\u2010protect\u2010public\u2010health\u2010reduce\u2010exposure\u2010ethylene\u2010oxide."},{"key":"e_1_2_10_6_1","unstructured":"\u201cFDA Facilitates Broader Adoption of Vaporized Hydrogen Peroxide for Medical Device Sterilization \u201dhttps:\/\/www.fda.gov\/news\u2010events\/press\u2010announcements\/fda\u2010facilitates\u2010broader\u2010adoption\u2010vaporized\u2010hydrogen\u2010peroxide\u2010medical\u2010device\u2010sterilization#:~:text=With%20the%20recent%20FDA%20recognition communities%20in%20which%20they%20operate."},{"key":"e_1_2_10_7_1","unstructured":"\u201cFDA Adds Vaporized Hydrogen Peroxide as Sterilization Alternative to EtO \u201dhttps:\/\/www.medtechdive.com\/news\/fda\u2010guidance\u2010vaporized\u2010hydrogen\u2010peroxide\u2010sterilization\/704316\/#:~:text=With%20the%20FDA's%20recent%20recognition is%20no%20FDA%20consensus%20standard."},{"key":"e_1_2_10_8_1","unstructured":"\u201cFDA Updates Sterilization Category to Encourage Vaporized Hydrogen Peroxide Use \u201dhttps:\/\/www.raps.org\/News\u2010and\u2010Articles\/News\u2010Articles\/2024\/1\/FDA\u2010updates\u2010sterilization\u2010category\u2010to\u2010encourage\u2010va."},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.1111\/jam.14412"},{"key":"e_1_2_10_10_1","unstructured":"\u201cEthylene Oxide \u201dhttps:\/\/www.epa.gov\/sites\/default\/files\/2016\u201009\/documents\/ethylene\u2010oxide.pdf."},{"issue":"2","key":"e_1_2_10_11_1","first-page":"121","article-title":"Aeration Time Following Ethylene Oxide Sterilization for Reusable Rigid Sterilization Containers: Concentration of Gaseous Ethylene Oxide in Containers","volume":"34","author":"Nakata S.","year":"2000","journal-title":"Biomedical Instrumentation & Technology"},{"key":"e_1_2_10_12_1","unstructured":"\u201cEthylene Oxide (EtO) Fact Sheet \u201dhttps:\/\/www.cdph.ca.gov\/Programs\/CCDPHP\/DEODC\/OHB\/HESIS\/CDPH%20Document%20Library\/eto.pdf."},{"key":"e_1_2_10_13_1","unstructured":"\u201cAgency for Toxic Substances and Disease Registry \u201d2019."},{"key":"e_1_2_10_14_1","unstructured":"National Center for Biotechnology Information \u201cPubChem Compound Summary for CID 784 Hydrogen Peroxide \u201dPubChem accessed February 12 2024 https:\/\/pubchem.ncbi.nlm.nih.gov\/compound\/Hydrogen\u2010Peroxide."},{"key":"e_1_2_10_15_1","unstructured":"National Center for Biotechnology Information \u201cPubChem Compound Summary for CID 6354 Ethylene Oxide \u201dPubChem accessed February12 2024 https:\/\/pubchem.ncbi.nlm.nih.gov\/compound\/Ethylene\u2010Oxide."},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.1107\/S0108768108010197"},{"key":"e_1_2_10_17_1","doi-asserted-by":"publisher","DOI":"10.1107\/S0365110X51000039"},{"key":"e_1_2_10_18_1","doi-asserted-by":"publisher","DOI":"10.1128\/aem.56.2.503\u2010506.1990"},{"key":"e_1_2_10_19_1","doi-asserted-by":"publisher","DOI":"10.1098\/rspa.1920.0034"},{"key":"e_1_2_10_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/B978-0-08-093250-7.00043-8"},{"key":"e_1_2_10_21_1","doi-asserted-by":"publisher","DOI":"10.1017\/CBO9780511805134"},{"key":"e_1_2_10_22_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.820190924"},{"key":"e_1_2_10_23_1","volume-title":"The Mathematics of Diffusion","author":"Crank J.","year":"1975"},{"key":"e_1_2_10_24_1","doi-asserted-by":"publisher","DOI":"10.1021\/ma301965y"},{"key":"e_1_2_10_25_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.a.35523"},{"key":"e_1_2_10_26_1","doi-asserted-by":"publisher","DOI":"10.1021\/acs.jpcb.3c05107"},{"key":"e_1_2_10_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0032-3861(00)00765-5"},{"key":"e_1_2_10_28_1","doi-asserted-by":"publisher","DOI":"10.1002\/1099-0488(20000801)38:15<2051::AID-POLB100>3.0.CO;2-D"},{"key":"e_1_2_10_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.sbsr.2018.10.001"},{"key":"e_1_2_10_30_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10765-012-1329-3"}],"container-title":["Journal of Biomedical Materials Research Part B: Applied Biomaterials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jbm.b.35567","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,15]],"date-time":"2025-05-15T12:58:32Z","timestamp":1747313912000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jbm.b.35567"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,16]]},"references-count":29,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2025,5]]}},"alternative-id":["10.1002\/jbm.b.35567"],"URL":"https:\/\/doi.org\/10.1002\/jbm.b.35567","archive":["Portico"],"relation":{},"ISSN":["1552-4973","1552-4981"],"issn-type":[{"value":"1552-4973","type":"print"},{"value":"1552-4981","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,16]]},"assertion":[{"value":"2024-08-26","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-03-10","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-04-16","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e35567"}}