{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,5]],"date-time":"2026-04-05T10:01:08Z","timestamp":1775383268803,"version":"3.50.1"},"reference-count":96,"publisher":"Wiley","issue":"10","license":[{"start":{"date-parts":[[2025,10,14]],"date-time":"2025-10-14T00:00:00Z","timestamp":1760400000000},"content-version":"vor","delay-in-days":13,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"DOI":"10.13039\/501100003086","name":"Eusko Jaurlaritza","doi-asserted-by":"publisher","award":["010\u2010B1\/2023"],"award-info":[{"award-number":["010\u2010B1\/2023"]}],"id":[{"id":"10.13039\/501100003086","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001872","name":"Centro para el Desarrollo Tecnol\u00f3gico Industrial","doi-asserted-by":"publisher","award":["SNEO\u201020181012"],"award-info":[{"award-number":["SNEO\u201020181012"]}],"id":[{"id":"10.13039\/501100001872","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Biomed Mater Res"],"published-print":{"date-parts":[[2025,10]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:p>\n                    Urethral stricture is the narrowing of the urethra caused by the growth of aberrant tissue after an injury. Actual post\u2010operative treatment requires the placement of a Foley catheter for external urinary drainage after surgery. However, it requires a second intervention for removal, and the contact with the external environment and non\u2010biodegradable composition even aggravates urinary tract infections (UTIs) in 7.12% of patients. Thus, we developed a completely biodegradable intraurethral device (BID) as an alternative to catheterization. BID is a continuous\u2010walled hollow tubular stent with outer wall corrugations composed of poly(\n                    <jats:sc>d<\/jats:sc>\n                    ,\n                    <jats:sc>l<\/jats:sc>\n                    \u2010lactide\u2010\n                    <jats:italic>co<\/jats:italic>\n                    \u2010\u03b5\u2010caprolactone) copolymer synthesized by ring\u2010opening polymerization, using a bismuth\u2010based catalyst. Complying with EU Medical Device Regulation 2017\/745, BID was manufactured by injection molding following ISO 13485 and irradiated by e\u2010beam, according to ISO 11137 and 11737. Physico\u2010chemical characterization was evaluated following ISO 10993, showing a scalable synthetic procedure with reproducible composition, high molecular weight, adequate thermal properties, and metal content below its cytotoxic level. Scanning electron microscopic analysis confirmed consistent dimensions and no detrimental effect in the device after irradiation. Additionally, hydrolytic degradation studies (static and dynamic) showed complete degradation of BID after 90\u2009days, obtained by the tailored composition of the synthesized copolymer and aligned with the tissue regeneration process. Mechanical properties confirmed a consistent tubular shape up to 28\u2009days and no migration of the device even at a maximum urine flow of 1500\u2009mL\/min thanks to the tailored corrugated design of BID. These findings position BID as a promising alternative in post\u2010operative urethral stricture management, addressing critical limitations of current practices. Hopefully, our BID might provide a biodegradable solution, minimizing UTIs and migration, and eliminating the current second intervention for catheter removal.\n                  <\/jats:p>","DOI":"10.1002\/jbm.b.35678","type":"journal-article","created":{"date-parts":[[2025,10,14]],"date-time":"2025-10-14T13:43:01Z","timestamp":1760449381000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Design, Manufacturing and Physicochemical Validation of a New Biodegradable Intraurethral Device for Post\u2010Operative Urethral Stricture Treatment"],"prefix":"10.1002","volume":"113","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4372-5306","authenticated-orcid":false,"given":"Laura","family":"Rubio\u2010Emazabel","sequence":"first","affiliation":[{"name":"Polimerbio SL  Donostia\u2010San Sebasti\u00e1n Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yurena","family":"Polo","sequence":"additional","affiliation":[{"name":"Polimerbio SL  Donostia\u2010San Sebasti\u00e1n Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Antonio","family":"Mu\u00f1oz","sequence":"additional","affiliation":[{"name":"Polimerbio SL  Donostia\u2010San Sebasti\u00e1n Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Geijo","sequence":"additional","affiliation":[{"name":"Polimerbio SL  Donostia\u2010San Sebasti\u00e1n Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jorge","family":"Fern\u00e1ndez","sequence":"additional","affiliation":[{"name":"Polimerbio SL  Donostia\u2010San Sebasti\u00e1n Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2025,10,14]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41598\u2010024\u201055408\u20108"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.3238\/arztebl.2013.0220"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.juro.2016.07.087"},{"key":"e_1_2_10_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.urology.2013.09.009"},{"key":"e_1_2_10_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.juro.2011.07.010"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-5347(01)65295-9"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.1308\/rcsann.2023.0003"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.a.31492"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.aju.2012.12.005"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/B978-0-12-802406-5.00003-3"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.5173\/ceju.2023.218"},{"key":"e_1_2_10_13_1","doi-asserted-by":"publisher","DOI":"10.3390\/vetsci9010013"},{"key":"e_1_2_10_14_1","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2024.1373130"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.1021\/bm025717o"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.1089\/end.2019.0493"},{"key":"e_1_2_10_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/B978-0-08-087780-8.00021-8"},{"key":"e_1_2_10_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.compositesb.2006.06.014"},{"key":"e_1_2_10_19_1","doi-asserted-by":"publisher","DOI":"10.3390\/polym14224924"},{"key":"e_1_2_10_20_1","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2021.617141"},{"key":"e_1_2_10_21_1","doi-asserted-by":"publisher","DOI":"10.3390\/polym12092010"},{"key":"e_1_2_10_22_1","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2023.1136077"},{"key":"e_1_2_10_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.engreg.2020.08.002"},{"key":"e_1_2_10_24_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00289\u2010021\u201003865\u2010w"},{"key":"e_1_2_10_25_1","doi-asserted-by":"publisher","DOI":"10.1116\/6.0000429"},{"key":"e_1_2_10_26_1","doi-asserted-by":"publisher","DOI":"10.1111\/jam.14290"},{"key":"e_1_2_10_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mtcomm.2022.104040"},{"key":"e_1_2_10_28_1","doi-asserted-by":"publisher","DOI":"10.3390\/polym13152412"},{"key":"e_1_2_10_29_1","doi-asserted-by":"publisher","DOI":"10.1039\/D2RA06831A"},{"key":"e_1_2_10_30_1","first-page":"27","article-title":"Injection Molding and 3D Printers","author":"Karag\u00f6z \u0130.","year":"2024","journal-title":"Advances in Research and Applications"},{"key":"e_1_2_10_31_1","doi-asserted-by":"publisher","DOI":"10.1021\/acsabm.2c00793"},{"key":"e_1_2_10_32_1","doi-asserted-by":"publisher","DOI":"10.1007\/s40264\u2010019\u201000878\u20103"},{"key":"e_1_2_10_33_1","unstructured":"Europa Regulation (EU) 2017\/745(2017) https:\/\/eur\u2010lex.europa.eu\/eli\/reg\/2017\/745\/oj."},{"key":"e_1_2_10_34_1","unstructured":"International Standard Organization Medical devices\u2014Quality Management Systems\u2014Requirements for Regulatory Purposes (ISO 13485:2016)(2016) https:\/\/www.iso.org\/standard\/59752.html."},{"key":"e_1_2_10_35_1","unstructured":"International Standard Organization Packaging for Terminally Sterilized Medical Devices (ISO 11607:2019)(2019) https:\/\/www.iso.org\/standard\/70799.html."},{"key":"e_1_2_10_36_1","unstructured":"International Standard Organization Sterilization of Health Care Products\u2014Radiation Part 1: Requirements for Development Validation and Routine Control of a Sterilization Process for Medical Devices (ISO 11137\u20101:2006)(2006) https:\/\/www.iso.org\/es\/contents\/data\/standard\/03\/39\/33952.html."},{"key":"e_1_2_10_37_1","unstructured":"International Standard Organization Sterilization of Health Care Products\u2014Microbiological Methods Part 1: Determination of a Population of Microorganisms on Products (ISO 11737\u20101:2018)(2018) https:\/\/www.iso.org\/standard\/66451.html."},{"key":"e_1_2_10_38_1","unstructured":"International Standard Organization Sterilization of Health Care Products\u2014Radiation Part 2: Establishing the Sterilization Dose (ISO 11137\u20102:2013)(2013) https:\/\/www.iso.org\/es\/contents\/data\/standard\/06\/24\/62442.html?browse=tc."},{"key":"e_1_2_10_39_1","unstructured":"International Standard Organization ISO 11737\u20102:2019 Sterilization of Health Care Products\u2014Microbiological Methods Part 2: Tests of Sterility Performed in the Definition Validation and Maintenance of a Sterilization Process (ISO 11737\u20102:2019)(2019) https:\/\/www.iso.org\/standard\/70801.html."},{"key":"e_1_2_10_40_1","unstructured":"International Standard Organization Biological Evaluation of Medical Devices Part 18: Chemical Characterization of Medical Device Materials Within a Risk Management Process (ISO 10993\u201018:2020)(2020) https:\/\/www.iso.org\/standard\/64750.html."},{"key":"e_1_2_10_41_1","unstructured":"International Standard Organization Biological Evaluation of Medical Devices Part 19: Physico\u2010Chemical Morphological and Topographical Characterization of Materials (ISO\/TS 10993\u201319:2020)(2020) https:\/\/www.iso.org\/es\/contents\/data\/standard\/07\/51\/75138.html."},{"key":"e_1_2_10_42_1","unstructured":"International Standard Organization Biological Evaluation of Medical Devices Part 13: Identification and Quantification of Degradation Products From Polymeric Medical Devices (ISO 10993\u201013:2010)(2010) https:\/\/www.iso.org\/standard\/44050.html."},{"key":"e_1_2_10_43_1","doi-asserted-by":"publisher","DOI":"10.1177\/1591019919833843"},{"key":"e_1_2_10_44_1","unstructured":"International Standard Organization Sterile Urethral Catheters for Single Use (ISO 20696:2018)(2018) https:\/\/www.iso.org\/es\/contents\/data\/standard\/06\/88\/68854.html?browse=tc."},{"key":"e_1_2_10_45_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ucl.2013.07.001"},{"key":"e_1_2_10_46_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0939\u20106411(99)00034\u2010X"},{"key":"e_1_2_10_47_1","doi-asserted-by":"publisher","DOI":"10.4314\/ijest.v2i2.59133"},{"key":"e_1_2_10_48_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.matpr.2017.01.164"},{"key":"e_1_2_10_49_1","doi-asserted-by":"publisher","DOI":"10.3390\/polym14010023"},{"key":"e_1_2_10_50_1","doi-asserted-by":"publisher","DOI":"10.1016\/B978-0-12-823023-7.00001-0"},{"key":"e_1_2_10_51_1","first-page":"119","volume-title":"Woodhead Publishing Series in Biomaterials","author":"Nelson K.","year":"2015"},{"key":"e_1_2_10_52_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2009.08.020"},{"key":"e_1_2_10_53_1","doi-asserted-by":"publisher","DOI":"10.1017\/ice.2017.301"},{"key":"e_1_2_10_54_1","doi-asserted-by":"publisher","DOI":"10.22207\/JPAM.14.3.46"},{"key":"e_1_2_10_55_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajic.2006.10.014"},{"key":"e_1_2_10_56_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.pnucene.2024.105481"},{"key":"e_1_2_10_57_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.msec.2016.07.031"},{"key":"e_1_2_10_58_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10924\u2010020\u201001972\u20109"},{"key":"e_1_2_10_59_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.nimb.2020.06.008"},{"key":"e_1_2_10_60_1","doi-asserted-by":"publisher","DOI":"10.1002\/mabi.202000379"},{"key":"e_1_2_10_61_1","doi-asserted-by":"publisher","DOI":"10.1089\/ten.TEA.2018.0130"},{"key":"e_1_2_10_62_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2023.105663"},{"key":"e_1_2_10_63_1","doi-asserted-by":"publisher","DOI":"10.1002\/pen.20882"},{"key":"e_1_2_10_64_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.rinma.2020.100149"},{"key":"e_1_2_10_65_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12262\u2010012\u20100549\u2010x"},{"key":"e_1_2_10_66_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.compositesb.2018.10.078"},{"key":"e_1_2_10_67_1","doi-asserted-by":"publisher","DOI":"10.3390\/polym15092047"},{"key":"e_1_2_10_68_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.reactfunctpolym.2020.104628"},{"key":"e_1_2_10_69_1","doi-asserted-by":"publisher","DOI":"10.3390\/polym14142790"},{"key":"e_1_2_10_70_1","doi-asserted-by":"publisher","DOI":"10.1016\/B978-0-323-37468-2.00002-6"},{"key":"e_1_2_10_71_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.matchemphys.2022.126325"},{"key":"e_1_2_10_72_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2005.03.002"},{"key":"e_1_2_10_73_1","doi-asserted-by":"publisher","DOI":"10.1002\/mame.202100602"},{"key":"e_1_2_10_74_1","doi-asserted-by":"publisher","DOI":"10.1002\/adfm.200801327"},{"key":"e_1_2_10_75_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2005.09.019"},{"key":"e_1_2_10_76_1","doi-asserted-by":"publisher","DOI":"10.3390\/molecules190915258"},{"key":"e_1_2_10_77_1","first-page":"414","volume-title":"Bismuth: Environmental Pollution and Health Effects","author":"Yang N.","year":"2011"},{"key":"e_1_2_10_78_1","doi-asserted-by":"publisher","DOI":"10.3390\/ijms25031600"},{"key":"e_1_2_10_79_1","doi-asserted-by":"publisher","DOI":"10.1016\/0016\u20105085(90)90983\u20108"},{"key":"e_1_2_10_80_1","doi-asserted-by":"publisher","DOI":"10.3390\/polym13244460"},{"key":"e_1_2_10_81_1","doi-asserted-by":"publisher","DOI":"10.3390\/molecules28155921"},{"key":"e_1_2_10_82_1","doi-asserted-by":"publisher","DOI":"10.1021\/acsmacrolett.8b00424"},{"key":"e_1_2_10_83_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.polymdegradstab.2014.12.019"},{"key":"e_1_2_10_84_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.b.35086"},{"key":"e_1_2_10_85_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.progpolymsci.2022.101556"},{"key":"e_1_2_10_86_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2012.03.008"},{"key":"e_1_2_10_87_1","doi-asserted-by":"publisher","DOI":"10.1089\/end.2005.0085"},{"key":"e_1_2_10_88_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.juro.2010.06.015"},{"key":"e_1_2_10_89_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.eucr.2019.100854"},{"key":"e_1_2_10_90_1","doi-asserted-by":"publisher","DOI":"10.1155\/2021\/9959074"},{"key":"e_1_2_10_91_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.eucr.2020.101482"},{"key":"e_1_2_10_92_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.a.35036"},{"key":"e_1_2_10_93_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1464\u2010410x.1989.tb05518.x"},{"key":"e_1_2_10_94_1","doi-asserted-by":"publisher","DOI":"10.21037\/tau.2019.08.16"},{"key":"e_1_2_10_95_1","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.30385"},{"issue":"10","key":"e_1_2_10_96_1","first-page":"3415","article-title":"Management of Recurrent Bulbar Urethral Stricture\u2014A 54 Patients Study With Allium Bulbar Urethral Stent (BUS)","volume":"7","author":"Culha M.","year":"2014","journal-title":"International Journal of Clinical and Experimental Medicine"},{"key":"e_1_2_10_97_1","doi-asserted-by":"publisher","DOI":"10.1590\/S1677\u20105538.IBJU.2014.01.12"}],"container-title":["Journal of Biomedical Materials Research Part B: Applied Biomaterials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jbm.b.35678","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T14:59:13Z","timestamp":1761663553000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jbm.b.35678"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10]]},"references-count":96,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2025,10]]}},"alternative-id":["10.1002\/jbm.b.35678"],"URL":"https:\/\/doi.org\/10.1002\/jbm.b.35678","archive":["Portico"],"relation":{},"ISSN":["1552-4973","1552-4981"],"issn-type":[{"value":"1552-4973","type":"print"},{"value":"1552-4981","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10]]},"assertion":[{"value":"2024-12-24","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-10-04","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-10-14","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e35678"}}